STEM: QUADRA-H CEMENTLESS, HA COATED LAT STEM SIZE 3
Report
- Report Number
- 3005180920-2020-00140
- Event Type
- Injury
- Date Received
- March 12, 2020
- Date of Event
- February 12, 2020
- Report Date
- March 12, 2020
- Manufacturer
- MEDACTA INTERNATIONAL SA
- Product Code
- JDI
- UDI-DI
- 07630030802157
- PMA / PMN Number
- K082792
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- GM
- Reporter Occupation
- 003
Narratives
BATCH REVIEW PERFORMED ON 21 FEBRUARY 2020: LOT 152983: (B)(4) ITEMS MANUFACTURED AND RELEASED ON 23-SET-2015. EXPIRATION DATE: 2020-09-07. NO ANOMALIES FOUND RELATED TO THE PROBLEM. TO DATE, (B)(4) ITEMS OF THE SAME LOT HAVE BEEN ALREADY SOLD WITHOUT ANY SIMILAR REPORTED SINCE 2016. CLINICAL EVALUATION PERFORMED BY MEDICAL AFFAIRS MANAGER: DELAYED INFECTION IN CEMENTLESS THA, 1 MONTH AFTER PRIMARY OPERATION. INFECTION IS A KNOWN POSSIBLE ADVERSE EVENT FOLLOWING EVERY SURGERY, INCLUDING THA'S. TO DATE, THERE IS NO REASON TO SUSPECT THAT THE CAUSE MAY BE LINKED TO THE IMPLANTED DEVICES. ADDITIONAL ITEMS INVOVLED IN THE EVENT, BATCH REVIEW PERFORMED ON 21 FEBRUARY 2020: CUP: VERSAFITCUP CC TRIO 01.26.45.0052 ACETABULAR SHELL CC TRIO Ø 52 (K103352) LOT. 1903297. LOT 1903297: (B)(4) ITEMS MANUFACTURED AND RELEASED ON 05-JULY-2019. EXPIRATION DATE: 2024-06-17. NO ANOMALIES FOUND RELATED TO THE PROBLEM. TO DATE, (B)(4) ITEMS OF THE SAME LOT HAVE BEEN ALREADY SOLD WITHOUT ANY SIMILAR REPORTED. LINER: CC E CC LIGHT 01.26.3644HCT FLAT PE HC LINER Ø 36 / E (K103352) LOT. 1904384. LOT 1904384: (B)(4) ITEMS MANUFACTURED AND RELEASED ON 21-JUNE-2019. EXPIRATION DATE: 2024-06-05. NO ANOMALIES FOUND RELATED TO THE PROBLEM. TO DATE, (B)(4) ITEMS OF THE SAME LOT HAVE BEEN ALREADY SOLD WITHOUT ANY SIMILAR REPORTED. BALL HEADS: MECTACER 01.29.208 BIOLOX DELTA CERAMIC BALL HEAD 12/14 Ø 36 SIZE S - 4 (K112115) LOT. 1903858. LOT 1903858: (B)(4) ITEMS MANUFACTURED AND RELEASED ON 24-JULY-2019. EXPIRATION DATE: 2024-07-10. NO ANOMALIES FOUND RELATED TO THE PROBLEM. TO DATE, (B)(4) ITEMS OF THE SAME LOT HAVE BEEN ALREADY SOLD WITHOUT ANY SIMILAR REPORTED.
REVISION SURGERY PERFORMED 1 MONTH AFTER THE PRIMARY DUE TO AN INFECTION. THE HEAD, STEM AND INLAY WERE REVISED AND THE PATHOGEN KIND IS UNKNOWN. THE STEM WAS LOOSE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 286071 | STEM: QUADRA-H CEMENTLESS, HA COATED LAT STEM SIZE 3 | CEMENTLESS STEM | JDI | MEDACTA INTERNATIONAL SA | 01.12.033 | 152983 | 07630030802157 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |