LAPAROSCOPIC SMOKE EVAC TUBING SET
Report
- Report Number
- 1320894-2020-00068
- Event Type
- Malfunction
- Date Received
- February 13, 2020
- Report Date
- March 31, 2020
- Manufacturer
- BUFFALO FILTER
- Product Code
- FYD
- PMA / PMN Number
- K924732
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- JA
- Reporter Occupation
- 003
Narratives
D10, H3: ALTHOUGH THE DEVICE IN QUESTION IS MANUFACTURED BY BUFFALO FILTER, A PRELIMINARY EVALUATION WAS PERFORMED BY CONMED. THE DEVICE WILL BE FORWARDED ON TO BUFFALO FILTER, THE MANUFACTURER AS WELL. H10: THE REPORTED EVENT OF INSUFFICIENT HEAT SEAL IS CONFIRMED. CONMED RECEIVED ONE 60-6810-001 IN UNOPENED ORIGINAL PACKAGING. THE LOT NUMBER WAS VERIFIED. A VISUAL INSPECTION WAS PERFORMED AND FOUND THE SEAL WAS NOT LINED UP PROPERLY. PERFORMED A FUNCTIONAL INSPECTION WITH DYE LEAK TESTING PER PROCEDURE WHICH INDICATED THAT THE PACKAGING DID HAVE AN INSUFFICIENT HEAT SEAL. ALTHOUGH A LOT NUMBER WAS PROVIDED, CONMED COULD NOT CONDUCT A TWO-YEAR LOT HISTORY REVIEW OR REVIEW THE MANUFACTURING DOCUMENTS FROM THE DEVICE HISTORY RECORD (DHR) AS THE DEVICE IS MANUFACTURED BY BUFFALO FILTER FOR CONMED. A RISK ANALYSIS CANNOT BE CONDUCTED FOR THIS DEVICE SINCE CONMED DOES NOT OWN THE RISK DOCUMENTS FOR THIS DEVICE. A TWO-YEAR LOT HISTORY REVIEW SHOWS THIS IS THE ONLY COMPLAINT FOR THIS LOT NUMBER AND FAILURE MODE. A TWO-YEAR REVIEW OF COMPLAINT HISTORY FOR THIS DEVICE FAMILY AND FAILURE MODE, REVEALED THERE HAS BEEN A TOTAL OF 1 COMPLAINTS, REGARDING 1 DEVICE, FOR THIS DEVICE FAMILY AND FAILURE MODE. DURING THIS SAME TIME FRAME 77,955 DEVICES HAVE BEEN MANUFACTURED AND SHIPPED WORLDWIDE. SHOULD ALL THE COMPLAINT DEVICES HAVE BEEN FOUND CONFIRMED FOR THIS REPORTED FAILURE, THE RATE OF FAILURE WOULD BE (B)(4). CONMED ENCOURAGES THE INSPECTION AND/OR TEST OF ALL MEDICAL EQUIPMENT PRIOR TO USE TO ENSURE ALL DEVICES ARE FUNCTIONING AS EXPECTED THIS ISSUE WILL CONTINUE TO BE MONITORED THROUGH THE COMPLAINT SYSTEM TO ASSURE PATIENT SAFETY.
AT TIME OF FILING, ALTHOUGH EXPECTED, THE REPORTED DEVICE HAS NOT BEEN RETURNED TO CONMED FOR EVALUATION. A SUPPLEMENTAL AND FINAL REPORT WILL BE FILED FOLLOWING THE COMPLETION OF THE DEVICE EVALUATION AND COMPLAINT INVESTIGATION. THIS ISSUE WILL CONTINUE TO BE MONITORED THROUGH THE COMPLAINT SYSTEM TO ASSURE PATIENT SAFETY.
DURING INCOMING INSPECTION, THE DISTRIBUTOR REJECTED THIS DEVICE, CATALOG # 60-6810-001, LAPAROSCOPIC SMOKE EVAC TUBING SET , LOT 140843, FOR A POSSIBLE INSUFFICIENT HEATSEAL. THERE WAS NO CONTACT WITH THE PATIENT AS THIS WAS FOUND DURING INCOMING INSPECTION. DUE TO THE POTENTIAL SEVERITY OF A BREACH IN STERILITY, THIS REPORT IS BEING RAISED AS A MALFUNCTION WITH POTENTIAL FOR INJURY UPON REOCCURRENCE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 172984 | LAPAROSCOPIC SMOKE EVAC TUBING SET | APPARATUS, EXHAUST, SURGICAL | FYD | BUFFALO FILTER | 140843 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |