FDA Adverse Event Injury Summary report: N

S4 SET SCREW NEW VERSION

MDR report key: 9702351 · Received February 12, 2020

Report

Report Number
9610612-2019-00950
Event Type
Injury
Date Received
February 12, 2020
Date of Event
January 17, 2020
Report Date
March 31, 2020
Manufacturer
AESCULAP AG
Product Code
MNI
PMA / PMN Number
K032219
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
JA
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

ASSOCIATED MEDWATCH-REPORTS: 9610612-2019-00949 ((B)(4),SW790T). GENERAL INFORMATION: INTRA OPERATIVE INCIDENT. THE SCREW ARRIVED IN DECONTAMINATED CONDITION. CONSEQUENCES FOR THE PATIENT: ACCORDING TO THE AVAILABLE INFORMATION THERE WERE NO NEGATIVE CONSEQUENCES FOR THE PATIENT. INVESTIGATION: WE MADE A VISUAL INSPECTION OF THE SCREW. IN THE FIRST STEP WE INVESTIGATED THE HEXAGON.THE HEXAGON EXHIBIT NO SIGNS OF WEAR OR DAMAGES, WHICH WERE SIGNS OF A NOT CORRECT APPLIED HEX- KEY. IN THE NEXT STEP WE INVESTIGATED THE BOTTOM OF THE SCREW. HERE WE FOUND THE TYPICALLY CIRCULAR WEAR OF A NOT PROPER TIGHTENED SCREW, RESPECTIVELY A SCREW WHO WAS TIGHTENED OVER A NOT CORRECT PLACED ROD. A SAMPLE OF THE BOTTOM AND THE WEAR MARKS OF A CORRECT INSERTED AND TIGHTENED SET SCREW IS SHOWN. BATCH HISTORY REVIEW: THE MANUFACTURING DOCUMENTS HAVE BEEN CHECKED AND FOUND TO BE ACCORDING TO SPECIFICATION VALID DURING THE TIME OF PRODUCTION. THERE ARE NO FURTHER COMPLAINTS WITH THIS LOT AT HAND. CONCLUSION AND ROOT CAUSE: THE ROOT CAUSE FOR THE PROBLEM IS MOST PROBABLY USAGE RELATED. RATIONALE: THE WEAR SHAPES ON THE BOTTOM OF THE SCREW ARE A SURE HINT FOR TIGHTENING WITH A NOT CORRECT (TILTED) APPLIED ROD. A MATERIAL FAILURE OR A MANUFACTURING ERROR CAN BE EXCLUDED. CORRECTIVE ACTION: ACCORDING TO SOP SA-DE13-M-4-2-04-000-0 (CORRECTIVE ACTION & PREVENTIVE ACTION) A CAPA IS NOT NECESSARY.

Additional Manufacturer Narrative · 1

IF ADDITIONAL INFORMATION BECOMES AVAILABLE A FOLLOW UP REPORT WILL BE SUBMITTED.

Description of Event or Problem · 1

IT WAS REPORTED THAT THERE WAS AN ISSUE WITH S4 SET SCREW. ACCORDING TO THE CUSTOMER COMPLAINT. "L4/L5 FIXATION USING S4 AND SRI(SPONDYLOLISTHESIS REDUCTION INSTRUMENT). WHEN INSERTING SET SCREWS INTO THE SCREWS IN L5, THE ROD WAS SLIGHTLY ELEVATED IN L4 SCREWS AND THERE WAS A SLIGHT GAP BETWEEN THE ROD AND THE SCREWS. IN RIGHT L4, THE SURGEON ATTEMPTED TO SCREW IN THE SET SCREW USING A SET SCREW STARTER, BUT THE SET SCREW ROTATED IDLY, SO HE REMOVED THE SET SCREW IN QUESTION TO REPLACE IT WITH A BRAND NEW ONE. THE SURGEON USED TWO SET SCREWS IN THE LEFT SCREW OF L4, BUT BOTH ROTATED IDLY IN THE LEFT SIDE, TOO. FINALLY, FOR THE RIGHT L4 SCREW, THE SURGEON MANAGED TO FIX THE SECOND SET SCREW, AND IT WAS SUCCESSFUL. FOR THE LEFT, THE SURGEON ATTEMPTED CAREFULLY TO FIX ONE OF THE TWO FAILED SET SCREWS, AND HE SUCCEEDED IN FINALLY TIGHTENING THE SET SCREW. THERE WAS NO NEED FOR REPLACEMENT OF PEDICLE SCREWS. IT IS UNKNOWN EXACTLY HOW LONG THE SURGICAL PROCEDURE WAS DELAYED. THERE WAS NO PATIENT HARM. ADDITIONAL INFORMATION WAS NOT PROVIDED NOR AVAILABLE / WAS NOT AVAILABLE. ADDITIONAL PATIENT INFORMATION IS NOT AVAILABLE. THE ADVERSE EVENT IS FILED UNDER (B)(4). ASSOCIATED MEDWATCH-REPORTS: 9610612-2019-00949 ((B)(4) SW790T).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
165447 S4 SET SCREW NEW VERSION SPINE SURGERY MNI AESCULAP AG SW790T 52457096

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention