FDA Adverse Event Malfunction Summary report: N

APPLICATION INSTRUMENT FOR STERNAL ZIPFIX

MDR report key: 9688010 · Received February 10, 2020

Report

Report Number
8030965-2020-01013
Event Type
Malfunction
Date Received
February 10, 2020
Date of Event
January 1, 2020
Report Date
January 21, 2020
Manufacturer
OBERDORF SYNTHES PRODUKTIONS GMBH
Product Code
JDQ
UDI-DI
07611819418424
PMA / PMN Number
K110789
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
IN
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

DEPUY SYNTHES IS SUBMITTING THIS REPORT PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH DEPUY SYNTHES HAS NOT BEEN ABLE TO INVESTIGATE OR VERIFY PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY FDA, DEPUY SYNTHES OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE DEVICE, DEPUY SYNTHES, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. H3, H6: PART: 03.501.080, LOT: L910437, MANUFACTURING SITE: HAEGENDORF, RELEASE TO WAREHOUSE DATE: JUNE 26, 2018. A MANUFACTURING RECORD EVALUATION WAS PERFORMED FOR THE FINISHED DEVICE LOT NUMBER, AND NO NON-CONFORMANCES WERE IDENTIFIED. VISUAL INSPECTION: THE APPLICATION INSTRUMENT FOR STERNAL ZIPFIX WAS RECEIVED WITH A BROKEN OFF PORTION OF THE CUTTER COMPONENT. THE BROKEN OFF PART IS MISSING AND WAS NOT RETURNED FOR THE INVESTIGATION. ALL FEATURES RELATED TO THE REPORTED COMPLAINT CONDITION WERE REVIEWED AND NO OTHER ISSUES WERE IDENTIFIED. DIMENSIONAL INSPECTION: DUE TO THE MISSING PART AND THE CONDITION OF THE RETURNED DEVICE, A DIMENSIONAL TEST IS NOT APPROPRIATE, AS ALL COMPLAINT-RELEVANT DIMENSIONS CANNOT BE MEASURED AND CAN NO LONGER CORRESPOND TO THE VALID TECHNICAL DRAWINGS SPECIFICATIONS DUE TO THE DAMAGE INCURRED. DRAWING/SPECIFICATION REVIEW: THE MANUFACTURING REVIEW SHOWS THAT THE PRODUCTION PROCEDURE WAS ACCORDING TO THE SPECIFICATIONS AND THERE WERE NO ISSUES THAT WOULD CONTRIBUTE TO THIS COMPLAINT CONDITION. SUMMARY: THE COMPLAINT CONDITION IS CONFIRMED AS THE RECEIVED DEVICE WAS FOUND BROKEN. DURING THE PERFORMED EVALUATION, NO MANUFACTURING RELATED ISSUE COULD BE DETECTED. BECAUSE OF THE DAMAGE AND THE MISSING BROKEN PART, THE FOR THE COMPLAINT RELEVANT DIMENSIONS CANNOT BE MEASURED ANYMORE. IT IS LIKELY THAT A MECHANICAL OVERLOAD SITUATION DURING USE LEAD TO THE BREAKAGE. DURING THE INVESTIGATION, NO PRODUCT DESIGN OR MANUFACTURING ISSUES WERE OBSERVED THAT MAY HAVE CONTRIBUTED TO THE COMPLAINT CONDITION. ADDITIONAL MONITORING FOR ANY POTENTIAL SAFETY SIGNALS WILL BE CONDUCTED THROUGH COMPLAINT TRENDING AND OTHER POST MARKET SAFETY SURVEILLANCE ACTIVITIES. BASED ON THE INVESTIGATION FINDINGS, IT HAS BEEN DETERMINED THAT NO CORRECTIVE AND/OR PREVENTATIVE ACTION IS PROPOSED AS NO PRODUCT RELATED ISSUE COULD BE DETECTED. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Additional Manufacturer Narrative · 0

DEPUY SYNTHES IS SUBMITTING THIS REPORT PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH DEPUY SYNTHES HAS NOT BEEN ABLE TO INVESTIGATE OR VERIFY PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY FDA, DEPUY SYNTHES OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE DEVICE, DEPUY SYNTHES, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Description of Event or Problem · 0

THE HOLDING TIP BROKE WHILE CLEANING THE APPLICATION INSTRUMENT FOR STERNAL ZIPFIX AFTER THE PROCEDURE IN THE STERILIZATION ROOM.

Additional Manufacturer Narrative · 1

PRODUCT COMPLAINT # (B)(4). COMPLAINANT PART IS EXPECTED TO BE RETURNED FOR MANUFACTURER REVIEW/INVESTIGATION, BUT HAS YET TO BE RECEIVED. THE INVESTIGATION COULD NOT BE COMPLETED; NO CONCLUSION COULD BE DRAWN AT THE TIME OF FILING THIS REPORT. A REVIEW OF THE DEVICE HISTORY RECORDS HAS BEEN REQUESTED. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Description of Event or Problem · 1

DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN (B)(4) AS FOLLOWS:: IT WAS REPORTED THAT THE DEVICE BROKEN WHILE CLEANING AFTER THE PROCEDURE. THIS COMPLAINT INVOLVES ONE (1) DEVICE. THIS REPORT IS 1 OF 1 FOR (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
153007 APPLICATION INSTRUMENT FOR STERNAL ZIPFIX CERCLAGE FIXATION JDQ OBERDORF SYNTHES PRODUKTIONS GMBH L910437 07611819418424

Patients

Seq Age Sex Outcome Treatment
1