FDA Adverse Event Injury Summary report: N

BD FLUNT FILL NEEDLE WITH FILTER

MDR report key: 9682030 · Received February 7, 2020

Report

Report Number
1911916-2020-00108
Event Type
Injury
Date Received
February 7, 2020
Date of Event
October 16, 2019
Report Date
January 31, 2020
Manufacturer
BD MEDICAL (BD WEST) MEDICAL SURGICAL
Product Code
GAA
UDI-DI
30382903052111
PMA / PMN Number
EXEMPT
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
PA, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

INVESTIGATION SUMMARY: NO SAMPLES WERE RECEIVED. TWO PHOTOS WERE PROVIDED. THEY SHOW A 1ML SYRINGE AND TWO NEEDLE ASSEMBLY PACKAGING BLISTERS ONE IS FOR A 30X ½ AND OTHER FOR 18X 1 ½ FILL NEEDLE. A DEVICE HISTORY RECORD REVIEW WAS COMPLETED WITH ZERO DEFECTS FOUND. NO QUALITY NOTIFICATIONS WERE WRITTEN FOR THIS BATCH, NOR FOR THE ASSOCIATED ASSEMBLY BATCHES. INVESTIGATION CONCLUSION: COMPLAINTS RECEIVED FOR THIS DEVICE AND REPORTED CONDITION WILL CONTINUE TO BE TRACKED AND TRENDED. INFORMATION WILL BE CAPTURED ON TREND REPORTS AND MONITORED MONTHLY. OUR BUSINESS TEAM REGULARLY REVIEWS THE COLLECTED DATA FOR IDENTIFICATION OF EMERGING TRENDS. ROOT CAUSE DESCRIPTION: ROOT CAUSE FOR THE REPORTED ISSUE CANNOT BE DETERMINED AS SAMPLES WOULD BE NEEDED FOR EVALUATION. RATIONALE: CAPA NOT REQUIRED AT THIS TIME.

Description of Event or Problem · 1

IT WAS REPORTED THAT BD FLUNT FILL NEEDLE WITH FILTER HAD FOREIGN MATTER WAS FOUND IN THE PATIENTS EYE AFTER INJECTION. INFLAMMATION OCCURRED ON 4 OCCASIONS DURING USE AND FOREIGN MATTER OCCURRED ON 5 OCCASIONS DURING USE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: MATERIAL NO.: 305211, BATCH NO.: 8173918. IT WAS REPORTED THAT SILICONE OIL DROPLETS AND METALLIC FLAKES WERE OBSERVED IN PATIENTS' EYE AFTER OCULAR INJECTION WHICH CAUSED SEVERAL CASES OF INFLAMMATION IN THE EYE. PR 3 OF 3: THIS PR IS FOR NEEDLE FILTER BLUNT FILL 18X1-1/2. PER COMPLAINT: WE ARE FACED WITH A TECHNICAL COMPLAINT WHERE THE DOCTOR OBSERVED THAT AFTER OCULAR INJECTION SILICONE OR SILICON LIKE DROPLETS WERE PRESENT IN THE EYE OF THE PATIENT WHICH CLAIMED IN 3 OF 4 CASES ABOUT EYE INFLAMMATION. ADDITIONALLY THE DOCTOR NOTICED "SMALL METALLIC, IRREGULARLY SHAPED SHIMMERING FLAKES FLOATING IN THE ANTERIOR VITREOUS". THEY OBSERVED AFTER OCULAR INJECTION USING THE SYRINGES AND NEEDLES PROVIDED FROM BD , SILICON OIL DROPLETS AND METALLIC FLAKES IN THE EYE OF THE PATIENT. THESE OBSERVATIONS WERE CONNECTED WITH AN INFLAMMATION OF THE EYES OF PATIENTS. FURTHERMORE WE WERE NOTIFIED THAT IT CAN BE A GENERAL ISSUE THAT SILICONE OIL DROPLETS ARE EXTRACTED FROM THE SYRINGE ONTO THE PRODUCT DOSED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
145728 BD FLUNT FILL NEEDLE WITH FILTER MANUAL SURGICAL INSTRUMENT FOR GENERAL USE GAA BD MEDICAL (BD WEST) MEDICAL SURGICAL 305211 8173918 30382903052111

Patients

Seq Age Sex Outcome Treatment
1 Other