HEMASHIELD MICROVEL DOUBLE VELOUR GRAFT
Report
- Report Number
- 2242352-1997-00047
- Event Type
- Injury
- Date Received
- June 5, 1997
- Date of Event
- May 14, 1997
- Report Date
- May 14, 1997
- Manufacturer
- MEADOX MEDICALS, DIV. BOSTON SCIENTIFIC CORP.
- Product Code
- MAL
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- TX, US
- Reporter Occupation
- PHYSICIAN
Narratives
AN UNIDENTIFIED SEGMENT OF GRAFT WAS RETURNED AND EVALUATED BY CO CONSULTING PATHOLOGIST. A COPY OF THAT RPT IS ATTACHED. ALTHOUGH THE EXACT BATCH NUMBER OF THE GRAFT THAT LEAKED IS UNK, THE MFG BATCH RECORDS FOR BOTH DEVICES WERE REVIEWED. THE BATCH RECORDS FOR BOTH BATCHES SHOWED NOTHING ATYPICAL. THERE ARE NO SIMILAR INCIDENTS AGAINST BATCH 296190. BATCH 056176 HAD ONE SIMILAR INCIDENT RPT'D, BUT FOR MINIMAL LEAKAGE. GROSS DESCRIPTION: RECEIVED IN FORMALIN IS A SEGMENT OF CRIMPED DACRON VASCULAR GRAFT MEASURING 38 CM IN LENGTH BY 1.1 CM IN OUTER DIAMETER. NO BLOOD OR TISSUE ELEMENTS ARE IDENTIFIED ON THE LUMINAL SURFACE OR THE PERIADVENTITIAL SURFACE. REP SECTIONS ARE EMBEDDED UNDER MD-959, MD-960 AND MD-961. MICROSCOPY DESCRIPTION: A COLLAGEN-COATED DACRON VASCULAR GRAFT WITH AN INTACT COLLAGEN IS IDENTIFIED. FOCAL AREAS OF BLOOD CELLS AND PROTEIN ARE IDENTIFIED FOCALLY ON THE LUMINAL AND PERIOADVERNTITIAL SURFACES.
THE DR ANASTOMOSED TWO 8MM DIAMETER HEMASHIELD GRAFTS, END-TO-END, FOR A DEEP BILATERAL AXILLARY-BIFEMORAL BYPASS PROCEDURE. DURING THE PROCEDURE, ONE OF THE GRAFTS LEAKED APPROX TWO UNITS OF BLOOD THROUGH ITS WALLS. THE OTHER WAS BLOOD-TIGHT. THE DRS ELECTED TO ALLOW THE GRAFT TO LEAK FOR APPROX 45 MINUTES WITHOUT ATTEMPTING TO STOP THE LEAKAGE. EVENTUALLY, THE LEAKAGE BECAME LESS. THE GRAFT THAT LEAKED WAS EXPLANTED AND REPLACED WITH A GORETEX GRAFT. THE OTHER GRAFT WAS LEFT IN THE PT AND REANASTOMOSED TO THAT GORETEX GRAFT. THE PT WAS GIVEN TWO UNITS OF BLOOD. THE PT'S CONDITION IS REPORTED AS OK. NOTE: THE TWO HEMASHIELD GRAFTS USED IN THIS PROCEDURE WERE BOTH CATALAOG 095208, BATCH NUMBER 056176 AND BATCH NUMBER 296190. UNFORTUNATELY THE HOSP IS UNABLE TO IDENTIFY WHICH BATCH NUMBER WAS THE ONE THAT LEAKED AND WHICH BATCH NUMBER WAS LEFT IN THE PT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | HEMASHIELD MICROVEL DOUBLE VELOUR GRAFT Implant | SEALED VASCULAR GRAFT | MAL | MEADOX MEDICALS, DIV. BOSTON SCIENTIFIC CORP. | 095208 | UNK |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | NO INFO | Other| R |