FDA Adverse Event Injury Summary report: N

HARMONIC ACE 5MM SHEAR

MDR report key: 9661825 · Received February 3, 2020

Report

Report Number
3005075853-2020-00719
Event Type
Injury
Date Received
February 3, 2020
Report Date
January 6, 2020
Manufacturer
ETHICON ENDO-SURGERY, LLC.
Product Code
LFL
PMA / PMN Number
K120729
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). DATE OF EVENT: PUBLICATION YEAR OF 2015. BATCH # UNK. THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE MANUFACTURING RECORDS CANNOT BE REVIEWED AS THE LOT/BATCH NUMBER HAS NOT BEEN PROVIDED.

Description of Event or Problem · 1

TITLE : IMPACT OF ENERGY DEVICES DURING LIVER PARENCHYMAL. TRANSECTION: A MULTICENTER RANDOMIZED CONTROLLED TRIAL. AUTHOR : NAOTO GOTOHDA ¿ TAKEHARU YAMANAKA ¿ AKIO SAIURA ¿ KATSUHIKO UESAKA ¿ MASAJI HASHIMOTO ¿ MASARU KONISHI ¿ KAZUAKI SHIMADA. CITATION: WORLD J SURG (2015); 39:1543¿1549. DOI 10.1007/S00268-015-2967-Y. THE OBJECTIVE OF THIS STUDY WAS TO CLARIFY THE BENEFIT OF ENERGY DEVICES SUCH AS ULTRASONICALLY ACTIVATED DEVICE AND BIPOLAR VESSEL SEALING DEVICE IN LIVER SURGERIES. THIS PROSPECTIVE MULTICENTER RANDOMIZED STUDY INVOLVES 211 PATIENTS SCHEDULED TO UNDERGO OPEN LIVER RESECTION FOR LIVER TUMOR BETWEEN MAY 2011 AND DECEMBER 2012. THE PATIENTS WERE RANDOMIZED INTO TWO GROUPS: IN EXPERIMENTAL GROUP (GROUP E), 107 PATIENTS (79 MALE; MEDIAN AGE: 63; AGE RANGE: 27-83; MEDIAN BMI: 22.5 KG/M2; BMI RANGE: 16.3-33,2 KG/M2) USED ENERGY DEVICE AND IN CONTROL GROUP (GROUP C), 104 PATIENTS (78 MALE; MEDIAN AGE: 64; AGE RANGE: 30-84; MEDIAN BMI: 22.0 KG/M2; BMI RANGE: 14.9 ¿ 32.6 KG/M2) DID NOT USE AN ENERGY DEVICE. AFTER THE PARENCHYMA WAS CRUSHED, THE EXPOSED VESSEL WERE LIGATED WITH A SILK STRING IN GROUP C, WHILE THE EXPOSED VESSELS WERE SEALED WITH AN ENERGY DEVICE (IF <5 MM, BUT LIGATED WITH A SILK STRING IF >5 MM) IN GROUP E; HARMONIC FOCUS (ETHICON) WAS USED IN 42 PATIENTS AND THE BIPOLAR VESSEL SEALING DEVICE WAS USED IN 65 PATIENTS. REPORTED COMPLICATIONS IN GROUP E INCLUDED SIGNIFICANT INTRAOPERATIVE BLOOD LOSS (N-?), BILE LEAKAGE (N-?), AND POSTOPERATIVE BLEEDING (N-?). IN CONCLUSION, THE USE OF ENERGY DEVICES DURING LIVER SURGERY IS CLINICALLY MEANINGFUL AS IT SHORTENS THE LIVER TRANSECTION TIME AND REDUCES THE INCIDENCE OF POSTOPERATIVE BILE LEAKAGE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
123710 HARMONIC ACE 5MM SHEAR INSTRUMENT, ULTRASONIC SURGICAL LFL ETHICON ENDO-SURGERY, LLC.

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention