HARMONIC SCALPEL CURVED SHEAR (EXACT CODE UNKNOWN)
Report
- Report Number
- 3005075853-2020-00635
- Event Type
- Injury
- Date Received
- January 31, 2020
- Report Date
- January 2, 2020
- Manufacturer
- ETHICON ENDO-SURGERY, LLC.
- Product Code
- GEI
- PMA / PMN Number
- GEI
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- OH, US
- Reporter Occupation
- OTHER
Narratives
(B)(4). EVENT DATE: PUBLICATION YEAR OF 2007. BATCH # UNK. THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE MANUFACTURING RECORDS CANNOT BE REVIEWED AS THE LOT/BATCH NUMBER HAS NOT BEEN PROVIDED. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. TO DATE NO RESPONSE HAS BEEN PROVIDED. IF FURTHER DETAILS ARE RECEIVED AT A LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. DID THE PATIENT WHO EXPERIENCED SYMPTOMATIC URINOMA WITH ABDOMINAL PAIN AND FEVER UTILIZE HARMONIC SCALPEL?
TITLE : LAPAROSCOPIC UPPER POLE PARTIAL. NEPHRECTOMY FOR DUPLICATED RENAL. COLLECTING SYSTEMS IN ADULT PATIENTS. AUTHOR : ROBERT ABOUASSALY, INDERBIR S. GILL, AND JIHAD H. KAOUK. CITATION: UROLOGY (2007); 69: 1202¿1205. DOI:10.1016/J.UROLOGY.2007.03.011. THE AUTHORS REPORTED THEIR EXPERIENCE WITH LAPAROSCOPIC UPPER POLE PARTIAL NEPHRECTOMY (LUPPN) IN ADULT PATIENTS WITH A DUPLICATED COLLECTING SYSTEM AND AN OBSTRUCTED, POORLY FUNCTIONING UPPER POLE RENAL MOIETY. THIS RETROSPECTIVE STUDY INVOLVES 5 PATIENTS (MEAN AGE: 45 YEARS; AGE RANGE: 21 TO 71 YEARS; BMI: 21 TO 27 KG/M2) WHO UNDERWENT LAPAROSCOPIC RESECTION OF UPPER POLE MOIETY FOR A DUPLICATED COLLECTING SYSTEM BETWEEN OCTOBER 2000 AND JUNE 2005. DURING THE PROCEDURE, THE RENAL UPPER POLE MOIETY WAS EXCISED ALONG THE ATROPHIC CLEAVAGE PLANE USING HARMONIC SCALPEL (ETHICON). REPORTED COMPLICATION INCLUDED SYMPTOMATIC URINOMA WITH ABDOMINAL PAIN AND FEVER (N-?) IN WHICH AN INTRA-ABDOMINAL DRAIN WAS PLACED. THE DRAINAGE GRADUALLY TAPERED OFF AND SYMPTOMS RESOLVED; THE DRAIN WAS REMOVED ON DAY 14 WITHOUT FURTHER COMPLICATION. THE FACT THAT THE RETROGRADE PYELOGRAM OF THE LOWER POLE WAS NORMAL SUGGESTS THAT THE URINE COLLECTION WAS CAUSED BY RESIDUAL UPPER POLE RENAL PARENCHYMA. IN CONCLUSION, THE LAPAROSCOPIC APPROACH TO PARTIAL NEPHRECTOMY FOR SYMPTOMATIC DUPLICATED SYSTEMS IN THE ADULT PATIENT IS SAFE AND EFFECTIVE AND OFFERS THE ADVANTAGE OF DECREASED MORBIDITY AND RAPID RECOVERY WITH AN EXCELLENT SUCCESS RATE, SIMILAR TO THAT WITH THE OPEN APPROACH.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 118108 | HARMONIC SCALPEL CURVED SHEAR (EXACT CODE UNKNOWN) | INSTRUMENT, ULTRASONIC SURGICAL | GEI | ETHICON ENDO-SURGERY, LLC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |