2.5NM TORQUE LIMITING NUT DRIVER
Report
- Report Number
- 2939274-2020-00485
- Event Type
- Malfunction
- Date Received
- January 28, 2020
- Report Date
- January 8, 2020
- Manufacturer
- WRIGHTS LANE SYNTHES USA PRODUCTS LLC
- Product Code
- HXX
- UDI-DI
- 10705034715339
- PMA / PMN Number
- EXEMPT
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CO, US
- Reporter Occupation
- OTHER
Narratives
DEPUY SYNTHES IS SUBMITTING THIS REPORT PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH DEPUY SYNTHES HAS NOT BEEN ABLE TO INVESTIGATE OR VERIFY PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY FDA, DEPUY SYNTHES OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE DEVICE, DEPUY SYNTHES, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. H3, H6: A PRODUCT INVESTIGATION WAS CONDUCTED. SYNTHES SERVICE AND REPAIR EVALUATION: THE CUSTOMER REPORTED THE DEVICE FAILED IN CALIBRATION. THE REPAIR TECHNICIAN REPORTED THE DEVICE FAILED HIGH IN CALIBRATION. THE CAUSE OF THE ISSUE IS FAILED HIGH. THE DEVICE WAS SENT TO THE VENDOR FOR REPAIR ON 24-JAN-2020. THE VENDOR WILL REPAIR THE DEVICE PER THE VENDOR WORK INSTRUCTIONS. THE DEVICE WILL BE RETURNED TO THE CUSTOMER UPON COMPLETION OF THE SERVICE AND REPAIR PROCESS. ATTACHED SERVICE RECORD ROUTER COMPLETED THROUGH OPERATION 21. FINALIZED SERVICE RECORD WILL BE ARCHIVED IN TUNGSTEN DOCUMENT MANAGEMENT SYSTEM. THE EVALUATION WAS CONFIRMED. SERVICE HISTORY: THE PREVIOUS SERVICE EVENT FOR PART NUMBER 03.615.040 WITH LOT NUMBER(S) 9831909-15 HAS BEEN REVIEWED. THE CUSTOMER CALLED IN A SERVICE REQUEST FOR THIS ITEM ON 8-JAN-2020 FOR LOCKING NUT FAILED IN CALIBRATION . THE ITEM WAS PREVIOUSLY RETURNED FOR SERVICE ON 7-MAR-2018 DUE TO OUT OF CALIBRATION. THE PREVIOUS SERVICE CONDITION OF OUT OF CALIBRATION IS RELEVANT TO THE CURRENT COMPLAINED ISSUE OF LOCKING NUT FAILED IN CALIBRATION . THE MANUFACTURE DATE OF THIS ITEM IS 8-AUG-2017. THE SERVICE HISTORY REVIEW IS CONFIRMED. US CUSTOMER QUALITY RETURNED PRODUCT INVESTIGATION FLOW: POWER TOOLS/CALIBRATION. FUNCTIONAL TEST BELOW PROVIDED BY TECOMET. SEE ATTACHMENT "TECOMET 03.615.040 LOT 9831909-15". VISUAL INSPECTION: THE RETURNED 2.5NM TORQUE LIMITING NUT DRIVER (P/N: 03.615.040, LOT #: 9831909-15) DISPLAYED NO DAMAGE OR DEFECT. FUNCTIONAL TEST: TORQUE TESTING REVEALED THE DEVICE'S TORQUE WAS TOO HIGH; THE DEVICE WAS ABLE TO BE RE-CALIBRATED AND RETURNED TO THE CUSTOMER. DOCUMENT/SPECIFICATION REVIEW: THE RELEVANT MANUFACTURED-TO/CURRENT ENGINEERING DRAWING WAS REVIEW DURING INVESTIGATION; NO DESIGN ISSUES WERE REVEALED DURING INVESTIGATION. INVESTIGATION CONCLUSION: THE COMPLAINT CONDITION WAS CONFIRMED. NO MANUFACTURING ISSUES WERE IDENTIFIED DURING INVESTIGATION. DURING THE INVESTIGATION, NO PRODUCT DESIGN ISSUES OR DISCREPANCIES WERE OBSERVED THAT MAY HAVE CONTRIBUTED TO THE COMPLAINT CONDITION. ADDITIONAL MONITORING FOR ANY POTENTIAL SAFETY SIGNALS WILL BE CONDUCTED THROUGH COMPLAINT TRENDING AND OTHER POST MARKET SAFETY SURVEILLANCE ACTIVITIES. THEREFORE, IT HAS BEEN DETERMINED THAT NO CORRECTIVE AND/OR PREVENTIVE ACTION IS PROPOSED. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.
REPORTER IS SYNTHES EMPLOYEE. THE DEVICE HAS BEEN RECEIVED, THE INVESTIGATION IS IN PROGRESS, NO CONCLUSION COULD BE DRAWN AT THE TIME OF FILING THIS REPORT. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.
IT WAS REPORTED THAT ON (B)(6) 2020, DURING TESTING AT SERVICE AND REPAIR, THE 2.5NM TORQUE LIMITER FOR LOCKING NUT FAILED IN CALIBRATION. THERE WAS NO PATIENT INVOLVEMENT. THIS REPORT IS FOR ONE (1) 2.5NM TORQUE LIMITING NUT DRIVER. THIS IS REPORT 1 OF 1 FOR COMPLAINT (B)(4).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 100848 | 2.5NM TORQUE LIMITING NUT DRIVER | SCREWDRIVERS | HXX | WRIGHTS LANE SYNTHES USA PRODUCTS LLC | 03.615.040 | 9831909-15 | 10705034715339 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |