VICRYL POLYGLACTIN 910 SUTURE UNKNOWN PRODUCT
Report
- Report Number
- 2210968-2020-00753
- Event Type
- Injury
- Date Received
- January 28, 2020
- Report Date
- January 8, 2020
- Manufacturer
- ETHICON INC.
- Product Code
- GAM
- PMA / PMN Number
- K022269
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- IN
- Reporter Occupation
- OTHER
Narratives
(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. CITATION: JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES (2013); 3(3): 211-215. DOI: 10.1089/LAP.2012.0303. (B)(4).
IT WAS REPORTED VIA A JOURNAL ARTICLE"TITLE: LAPAROSCOPIC CHOLEDOCHOLITHOTOMY WITH RIGID NEPHROSCOPE". AUTHORS: RAJEEV SINHA, MS, FICS, FAIS. CITATION: JOURNAL OF LAPAROENDOSCOPIC & ADVANCED SURGICAL TECHNIQUES (2013); 3(3): 211-215. DOI: 10.1089/LAP.2012.0303. APART FROM THE REQUIRED EXPERTISE, A MAJOR DETERRENT TO LAPAROSCOPIC COMMON BILE DUCT (CBD) LITHOTOMY (LCDL) REMAINS THE RELATIVELY PROHIBITIVE COST OF THE FLEXIBLE CHOLEDOCHOSCOPE, AND IT ALSO HAS A SHORTCOMING OF NOT BEING EFFECTIVE IN REMOVAL OF LARGE IMPACTED CBD STONES. THIS STUDY INVOLVES 172 CONSECUTIVE PATIENTS (19 MALES; AGE RANGE: 13 TO 78 YEARS) WITH CBD STONES WHO WERE TREATED WITH TRANSDOCHAL LCDL FROM JANUARY 2002 TO MAY 2012. DURING THE PROCEDURE, THE ANTERIOR SURFACE OF THE COMMON BILE DUCT (CBD) WAS CLEARED OFF THE ANTERIOR LEAF OF THE VISCERAL PERITONEUM USING A HARMONIC SCALPEL (ETHICON). AFTER THOROUGH FLUSHING AND ENSURING TOTAL CLEARANCE OF THE CBD, BY VISUALIZING ITS AMPULLARY END, THE CBD WAS CLOSED WITHOUT A STENT, WITH CONTINUOUS 3-0 POLYGLACTIN ACID (VICRYL; ETHICON) SUTURING. REPORTED COMPLICATIONS INCLUDED POSTOPERATIVE MILD ACUTE PANCREATITIS (N-?) WHICH RESPONDED TO CONSERVATIVE TREATMENT AND RESOLVED COMPLETELY WITHIN A WEEK, AND BILIARY PERITONITIS (N-?) WHICH RESPONDED TO CONSERVATIVE TREATMENT AND RESOLVED CONSERVATIVELY. IN CONCLUSION, RIGID SCOPE TRANSDOCHAL LCDL IS FEASIBLE, PROBABLY EASIER, BETTER FOR IMPACTED LARGE CBD STONES, AND DEFINITELY MORE AFFORDABLE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 101561 | VICRYL POLYGLACTIN 910 SUTURE UNKNOWN PRODUCT | SUTURE, ABSORBABLE, SYNTHETIC | GAM | ETHICON INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |