FDA Adverse Event Malfunction Summary report: N

BD ULTRA FINE PEN NEEDLES

MDR report key: 9634491 · Received January 27, 2020

Report

Report Number
9616657-2020-00014
Event Type
Malfunction
Date Received
January 27, 2020
Date of Event
January 6, 2020
Report Date
January 8, 2020
Manufacturer
BECTON, DICKINSON AND CO.
Product Code
FMI
UDI-DI
10885403928659
PMA / PMN Number
K162516
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

DATE OF EVENT: UNKNOWN. THE DATE RECEIVED BY MANUFACTURER HAS BEEN USED FOR THIS FIELD. INVESTIGATION SUMMARY: LEVEL A INVESTIGATION - COMPLAINT EVALUATION / COMPLAINT HISTORY CHECK FOR THE EVENT(S) THAT OCCURRED. SEVERITY: S_2__; OCCURRENCE: A COMPLAINT HISTORY CHECK WAS PERFORMED AND THIS IS THE 2ND RELATED COMPLAINT FOR NEEDLE CLOG ON LOT # 9121946. INVESTIGATION SUMMARY: NO SAMPLES (INCLUDING PHOTOS) WERE RETURNED THEREFORE THE COMPLAINT COULD NOT BE CONFIRMED AND THE ROOT CAUSE IS UNDETERMINED. IF SAMPLES ARE RECEIVED IN THE FUTURE THE COMPLAINT WILL BE REOPENED FOR FURTHER INVESTIGATION. A LOT HISTORY REVIEW WAS CARRIED OUT AND NO RELATED NON CONFORMANCE'S WERE RAISED IN ASSOCIATION WITH THIS PACKAGED LOT CONCLUDING ALL INSPECTIONS WERE PERFORMED PER THE APPLICABLE OPERATIONS AND MET QC SPECIFICATIONS. INVESTIGATION CONCLUSION: AS NO SAMPLES AND/OR PHOTO(S) WERE RECEIVED THE INVESTIGATION CONCLUDED: UNCONFIRMED: BD WAS NOT ABLE TO DUPLICATE OR CONFIRM THE CUSTOMER¿S INDICATED FAILURE AS NO SAMPLES OR PHOTOS WERE RETURNED. COMPLAINTS RECEIVED FOR THIS DEVICE AND REPORTED CONDITION WILL CONTINUE TO BE TRACKED AND TRENDED. INFORMATION WILL BE CAPTURED ON TREND REPORTS AND MONITORED MONTHLY. OUR BUSINESS TEAM REGULARLY REVIEWS THE COLLECTED DATA FOR IDENTIFICATION OF EMERGING TRENDS. ROOT CAUSE DESCRIPTION: ROOT CAUSE CANNOT BE DETERMINED AT THIS TIME AS THE ISSUE IS UNCONFIRMED AS NO SAMPLES OR PHOTOS WERE RETURNED. RATIONALE: BASED ON THE INVESTIGATION, NO ADDITIONAL INVESTIGATION AND NO CAPA IS REQUIRED AT THIS TIME.

Description of Event or Problem · 1

IT WAS REPORTED THAT BD ULTRA FINE¿ PEN NEEDLES HAD NO INSULIN FLOW DURING PRIMING. THIS OCCURRED ON 4 OCCASIONS DURING USE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: MATERIAL NO.: 320122 BATCH NO.: 9121946. IT WAS REPORTED THERE WAS NO INSULIN FLOW DURING PRIMING. VERBATIM: CONSUMER REPORTED, WHEN PRIMING, NO INSULIN FLOWS. STATED, DOES NOT TRY TO INJECT IF SHE CAN'T PRIME.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
98240 BD ULTRA FINE PEN NEEDLES HYPODERMIC SINGLE LUMEN NEEDLE FMI BECTON, DICKINSON AND CO. 2865 9121946 10885403928659

Patients

Seq Age Sex Outcome Treatment
1 Other