HARMONIC ACE 5MM SHEAR
Report
- Report Number
- 3005075853-2019-24472
- Event Type
- Injury
- Date Received
- December 17, 2019
- Date of Event
- January 1, 2014
- Report Date
- November 21, 2019
- Manufacturer
- ETHICON ENDO-SURGERY, LLC.
- Product Code
- LFL
- PMA / PMN Number
- K120729
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Occupation
- OTHER
Narratives
(B)(4). DATE SENT: 12/17/2019. DATE OF EVENT: PUBLICATION YEAR OF 2014. BATCH # UNK. THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE MANUFACTURING RECORDS CANNOT BE REVIEWED AS THE LOT/BATCH NUMBER HAS NOT BEEN PROVIDED. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. TO DATE NO RESPONSE HAS BEEN PROVIDED. IF FURTHER DETAILS ARE RECEIVED AT A LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. DOES THE AUTHOR/SURGEON BELIEVE THAT THE ETHICON DEVICE CAUSED OR CONTRIBUTED TO THE PATIENT COMPLICATIONS MENTIONED IN THE ARTICLE? IF YES, PLEASE EXPLAIN.
TITLE: TRANSVAGINAL SPECIMEN EXTRACTION VERSUS CONVENTIONAL MINILAPAROTOMY AFTER LAPAROSCOPIC ANTERIOR RESECTION FOR COLORECTAL CANCER: MID-TERM RESULTS OF A CASE-MATCHED STUDY. AUTHOR/S: HYE JIN KIM, GYU-SEOG CHOI, JUN SEOK PARK, SOO YEUN PARK, JONG PIL RYUK, SUNG HWAN YOON. CITATION: SURG ENDOSC (2014) 28:2342¿2348; DOI 10.1007/S00464-014-3466-1. THIS PROSPECTIVELY COLLECTED DATABASE STUDY AIMED TO DESCRIBE THE SURGICAL TECHNIQUE FOR TOTALLY LAPAROSCOPIC ANTERIOR RESECTION WITH TRANSVAGINAL SPECIMEN EXTRACTION (TVSE) IN FEMALE PATIENTS WITH LEFT-SIDED COLORECTAL CANCER AND TO COMPARE THE CLINICAL OUTCOMES IN PATIENTS WITH TVSE WITH A CASE-MATCHED GROUP OF PATIENTS UNDERGOING CONVENTIONAL LAPAROSCOPIC ANTERIOR RESECTION WITH MINILAPAROTOMY (LAP) BASED ON A LARGE. FROM OCT2006 TO JUL2011, 58 FEMALE PATIENTS UNDERWENT TVSE FOR LEFT-SIDE COLORECTAL CANCER. THESE PATIENTS WERE CASE-MATCHED WITH 59 PATIENTS WHO UNDERWENT CONVENTIONAL LAP. IN TVSE GROUP, RECTAL TRANSECTION WAS ACHIEVED WITH 60-MM ENDOSCOPIC LINEAR STAPLER. AFTER RESECTION OF THE RECTUM, THE PROXIMAL COLON WAS DIVIDED INTRACORPOREALLY. A PLASTIC BAG (LAP BAG; SEJONG MEDICAL, (B)(4)) WAS INSERTED THROUGH THE VAGINAL PORT, AND THE SPECIMEN WAS PLACED INSIDE THE BAG. NEXT, THE VAGINAL COLPOTOMY WAS ENLARGED TO 3¿4 CM IN LENGTH USING ULTRASONIC SHEARS (HARMONIC SCALPEL; ETHICON ENDO-SURGERY INC., (B)(4), USA) FROM THE ABDOMINAL SIDE. INTRAOPERATIVE MORBIDITY INCLUDED BLEEDING (N=?). POSTOPERATIVE COMPLICATION INCLUDED BLEEDING (N=1) WHICH REQUIRED TRANSFUSION, AND VAGINAL SPOTTING AFTER SURGERY (N=1) WHICH RESOLVED AFTER 1 MONTH WITHOUT TREATMENT. IN THIS STUDY, AFTER 3-MONTH FOLLOW-UP VISITS, THE PATIENTS DID NOT COMPLAIN OF COLPOTOMY-RELATED SYMPTOMS, EXCEPT FOR ONE PATIENT WHO HAD VAGINAL SPOTTING FOR 1 MONTH. THE TVSE GROUP EXPERIENCED SUPERIOR POSTOPERATIVE OUTCOMES WITH EARLIER RETURN OF BOWEL FUNCTION, DECREASED PAIN, AND FEWER WOUND COMPLICATIONS, ALTHOUGH THE MEAN OPERATIVE TIME WAS LONGER RELATIVE TO THAT IN THE LAP GROUP.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1277001 | HARMONIC ACE 5MM SHEAR | INSTRUMENT, ULTRASONIC SURGICAL | LFL | ETHICON ENDO-SURGERY, LLC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |