ULTRACISION HARMONIC ACE (EXACT CODE UNKNOWN)
Report
- Report Number
- 3005075853-2019-24084
- Event Type
- Injury
- Date Received
- December 9, 2019
- Report Date
- November 11, 2019
- Manufacturer
- ETHICON ENDO-SURGERY, LLC.
- Product Code
- LFL
- PMA / PMN Number
- K051036
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- IN
- Reporter Occupation
- OTHER
Narratives
(B)(4). DATE OF EVENT: PUBLICATION YEAR OF 2019. BATCH # UNK. THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE MANUFACTURING RECORDS CANNOT BE REVIEWED AS THE LOT/BATCH NUMBER HAS NOT BEEN PROVIDED.
TITLE: LAPAROSCOPIC TRANSPERITONEAL HEMINEPHRECTOMY FOR TREATMENT OF THE NONFUNCTIONING MOIETY OF DUPLEX KIDNEY IN ADULTS: A CASE SERIES AUTHORS: MANMEET SINGH, SAMARTH AGARWAL, APUL GOEL, MANOJ KUMAR, ASHISH SHARMA, SIDDHARTH PANDEY, SATYNARAYAN SANKHWAR CITATION: INVESTIG CLIN UROL 2019; 60:210-215. THE AIM OF THIS RETROSPECTIVE STUDY IS TO REPORT THE RESULTS AND EXPERIENCE OF A TERTIARY CARE CENTER IN LAPAROSCOPIC TRANSPERITONEAL HEMINEPHRECTOMY FOR THE TREATMENT OF A NON-FUNCTIONING UPPER POLE MOIETY OF DUPLEX KIDNEY IN ADULTS. BETWEEN 2010 AND 2015, A TOTAL OF 17 PATIENTS (N=7 MALES N=10 FEMALES, MEAN AGE: 32 YEARS, RANGE: 19-44 YEARS, MEAN BMI: 28 KG/M2) WERE INCLUDED IN THE STUDY. THE HARMONIC SCALPEL (ETHICON) SEPARATED THE UPPER POLE FROM THE REST OF THE RENAL PARENCHYMA. TWO PATIENTS HAD AN OPENING OF THE CALYCES THAT WAS SUTURED INTRAOPERATIVELY WITH VICRYL 3-0 (ETHICON). COMPLAINTS INCLUDED A PATIENT (N= (B)(6) MALE) HAD CLAVIEN-DINDO GRADE 3 COMPLICATION SHOWING CONTINUOUS EXTENSIVE DRAINAGE FOR 5 DAYS IN THE POSTOPERATIVE PERIOD. ON THE 5TH POSTOPERATIVE DAY, RETROGRADE PYELOGRAPHY WAS PERFORMED, AND A LEAK WAS SEEN NEAR THE UPPER PART OF THE URETER THAT WAS THOUGHT TO BE DUE TO AN IATROGENIC INJURY SUSTAINED WHILE THE DISEASED URETER WAS BEING DISSECTED. CONSEQUENTLY, THE PATIENT WAS STENTED WITH A 5-FR DOUBLE J STENT, AFTER WHICH THE OUTPUT REDUCED DRAMATICALLY. THE OTHER PATIENT (N= (B)(6) FEMALE) ALSO DEVELOPED A CLAVIEN-DINDO GRADE 3 COMPLICATION. ALTHOUGH THIS PATIENT WAS DISCHARGED ON DAY 3, SHE WAS READMITTED ON DAY 7 WITH SUDDEN-ONSET, SEVERE FLANK PAIN. A CONTRAST-ENHANCED CT SCAN SHOWED THAT SHE HAD A URINOMA OF AROUND 300 ML IN VOLUME. IT WAS DRAINED PERCUTANEOUSLY WITH ULTRASOUND GUIDANCE UNDER LOCAL INFILTRATION. AFTER ASPIRATION, THE PATIENT¿S SYMPTOMS IMPROVED RAPIDLY WITHIN 24 HOURS AND SHE WAS COMPLETELY PAIN-FREE AFTER 48 HOURS. A REPEAT ULTRASOUND AFTER 48 HOURS SHOWED NO RESIDUAL COLLECTION IN THE PERINEPHRIC REGION AND SHE WAS DISCHARGED. IN CONCLUSION, LAPAROSCOPIC HEMINEPHRECTOMY IS PLAYING A CORNERSTONE ROLE IN THE TREATMENT OF THE NON-FUNCTIONING MOIETY OF DUPLEX KIDNEYS. THE PROCEDURE IS SAFE, EFFICIENT AND OFFERS THE TYPICAL PREOPERATIVE AND POSTOPERATIVE BENEFITS OF LAPAROSCOPIC SURGERY. THE RATE OF COMPLICATIONS IN ADULTS IS ACCEPTABLE AND IS SIMILAR TO THAT REPORTED IN PEDIATRIC PATIENTS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1235834 | ULTRACISION HARMONIC ACE (EXACT CODE UNKNOWN) | INSTRUMENT, ULTRASONIC SURGICAL | LFL | ETHICON ENDO-SURGERY, LLC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |