HARMONIC SCALPEL CURVED SHEAR (EXACT CODE UNKNOWN)
Report
- Report Number
- 3005075853-2019-24074
- Event Type
- Injury
- Date Received
- December 6, 2019
- Date of Event
- January 1, 2004
- Report Date
- November 7, 2019
- Manufacturer
- ETHICON ENDO-SURGERY, LLC.
- Product Code
- GEI
- PMA / PMN Number
- GEI
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- IT
- Reporter Occupation
- OTHER
Narratives
(B)(4). DATE OF EVENT: PUBLICATION YEAR OF 2004. BATCH # UNK. THE LOT/BATCH WAS NOT PROVIDED; THEREFORE, THE MANUFACTURING RECORDS COULD NOT BE REVIEWED. (B)(4).
IT WAS REPORTED VIA LITERATURE ENTITLED: THE USE OF BOVINE PERICARDIAL STRIPS ON LINEAR STAPLER TO REDUCE EXTRALUMINAL BLEEDING DURING LAPAROSCOPIC GASTRIC BYPASS: PROSPECTIVE RANDOMIZED CLINICAL TRIAL. AUTHOR/S: LUIGI ANGRISANI, MD, CHM; MICHELE LORENZO, MD, PHD; VINCENZO BORRELLI, MD; MONICA CIANNELLA, MD; UBERTO ANDREA BASSI, MD; PAOLO SCARANO, MD. CITATION: OBESITY SURGERY. 14: 1198-1202. A PROSPECTIVE COMPARISON WAS CONDUCTED OF EXTRALUMINAL BLEEDING FOLLOWING GASTRIC TRANSECTION WITH OR WITHOUT STAPLE-LINE REINFORCEMENT BY DEHYDRATED BOVINE PERICARDIUM DURING LAPAROSCOPIC ROUX-EN-Y GASTRIC BYPASS (LRYGBP). FROM JANUARY 2001 TO SEPTEMBER 2003, A TOTAL OF 98 CONSECUTIVE MORBIDLY OBESE PATIENTS UNDERWENT LRYGBP. PATIENTS WERE RANDOMLY ALLOCATED TO 2 GROUPS ACCORDING TO THE USE (GROUP A, 50 PATIENTS; AGE RANGE: 19 TO 58 YEARS OLD; 12 MALE AND 38 FEMALE PATIENTS; BMI: 37 TO 59) OR NOT (GROUP B, 48 PATIENTS; AGE RANGE: 20 TO 60 YEARS OLD; 10 MALE AND 38 FEMALE PATIENTS; BMI: 38 TO 58) OF DEHYDRATED BOVINE PERICARDIUM. IN BOTH GROUPS, DISSECTION WAS STARTED AT THE EQUATOR OF THE BALLOON IN THE PERI-GASTRIC SPACE BETWEEN THE NEUROVASCULAR BUNDLE OF LATARJET AND LESSER CURVATURE OF THE STOMACH USING THE HARMONIC SCALPEL (ETHICON). THE ANASTOMOSIS WAS COMPLETED BY PDS 2-0 CONTINUOUS SUTURES (ETHICON). IN GROUP A, REPORTED COMPLICATIONS INCLUDED SHORT GASTRIC VESSELS BLEEDING (N-1) WHICH REQUIRED CONVERSION TO LAPAROTOMY. IN GROUP B, REPORTED COMPLICATIONS INCLUDED LEAK (N-7) WHICH REQUIRED INTERRUPTED STITCHES INSERTED TO CONTROL THE LEAK IN 1 CASE AND ONE CASE OF POSTERIOR LEAK AND UNSATISFACTORY EXPOSURE WHICH REQUIRED CONVERSION TO LAPAROTOMY. IN CONCLUSION, PERI-STRIPS DRY CAN BE SAFELY APPLIED TO LINEAR STAPLERS FOR LRYGBP. THE BENEFIT OF PSD REINFORCEMENT OF THE GASTRIC STAPLE-LINES TO PREVENT BLEEDING WAS DEMONSTRATED BY A SIGNIFICANT REDUCTION IN THE NUMBER OF ENDO-CLIPS USED. AS A CONSEQUENCE OF LESS STAPLE-LINE BLEEDING, A DRY OPERATING FIELD WAS OBTAINED. THE EXTRA TIME REQUIRED TO IDENTIFY A BLEEDING SOURCE AND CONTROL IT WAS SAVED, AND THE TOTAL OPERATING-TIME WAS SIGNIFICANTLY REDUCED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1228351 | HARMONIC SCALPEL CURVED SHEAR (EXACT CODE UNKNOWN) | ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES | GEI | ETHICON ENDO-SURGERY, LLC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |