ULTRACISION HARMONIC ACE (EXACT CODE UNKNOWN)
Report
- Report Number
- 3005075853-2019-24069
- Event Type
- Injury
- Date Received
- December 6, 2019
- Date of Event
- January 1, 2012
- Report Date
- November 11, 2019
- Manufacturer
- ETHICON ENDO-SURGERY, LLC.
- Product Code
- LFL
- PMA / PMN Number
- K051036
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA
- Reporter Occupation
- OTHER
Narratives
(B)(4). DATE OF EVENT: PUBLICATION YEAR OF 2012. BATCH # UNK. THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT/BATCH NUMBER HAS NOT BEEN PROVIDED. (B)(4).
IT WAS REPORTED VIA LITERATURE ENTITLED: EIGHT YEAR EXPERIENCE WITH ENDOSCOPIC RADIAL ARTERY HARVEST AT A CANADIAN CENTRE. AUTHOR/S: SWINAMER S.A.; FOX S.; CHU M.; NOVICK R.; QUANTZ M.; MYERS M.; GUO R.; MCKENZIE N.; SY J.; KIAII B. CITATION: CANADIAN JOURNAL OF CARDIOLOGY. CONFERENCE: 65TH ANNUAL MEETING OF THE CANADIAN CARDIOVASCULAR SOCIETY. TORONTO, ON CANADA. CONFERENCE PUBLICATION: (VAR.PAGINGS). 28 (5 SUPPL. 1) (PP S187), 2012. DATE OF PUBLICATION: SEPTEMBER-OCTOBER 2012. THE AUTHORS PRESENTED THEIR EXPERIENCE AND OUTCOMES WITH THE TECHNIQUE (ENDOSCOPIC RADIAL ARTERY HARVEST) OVER 8 YEARS. FROM JULY 2004 TO MAY 2012, 580 PATIENTS UNDERWENT ENDOSCOPIC RADIAL ARTERY HARVEST (ERAH). A REUSABLE ESVH SYSTEM WITH THE ADDITION OF A HARMONIC ULTRASONIC SCALPEL/SHEARS (ETHICON) WAS USED TO FACILITATE THE REMOVAL OF THE RADIAL ARTERY (RA) FOR USE IN THE CABG PATIENTS. REPORTED COMPLICATION INCLUDED BLEEDING (N-8) IN WHICH THE PATIENTS REQUIRED THE ADDITIONAL OF A SECOND PROXIMAL ARM INCISION TO CONTROL THE BLEEDING, NEUROLOGICAL IMPAIRMENTS CONSISTED OF TRANSIENT NUMBNESS OVER THE THENAR EMINENCE, INDEX FINGER AND LATERAL FOREARM (N-?) AND CHRONIC NEURALGIAS (N-3). IN CONCLUSION, ERAH CAN BE EFFECTIVELY AND SAFELY ADOPTED AS A HARVEST TECHNIQUE FOR THE RA FOR CABG. THE RESULTS DEMONSTRATE ERAH PROVIDES ADEQUATE LENGTH CONDUITS IN A TIMELY MANNER THROUGH MUCH SMALLER INCISIONS WITHOUT INTIMAL TRAUMA RESULTING IN LOW RATES OF INFECTION AND NEUROLOGICAL IMPAIRMENT AND A VERY HIGH LEVEL OF PATIENT SATISFACTION.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1228329 | ULTRACISION HARMONIC ACE (EXACT CODE UNKNOWN) | INSTRUMENT, ULTRASONIC SURGICAL | LFL | ETHICON ENDO-SURGERY, LLC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |