HARMONIC SCALPEL CURVED SHEARS
Report
- Report Number
- 3005075853-2019-23813
- Event Type
- Injury
- Date Received
- November 27, 2019
- Date of Event
- January 1, 2008
- Report Date
- October 31, 2019
- Manufacturer
- ETHICON ENDO-SURGERY, LLC.
- Product Code
- GEI
- PMA / PMN Number
- GEI
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- IT
- Reporter Occupation
- OTHER
Narratives
(B)(4). DATE OF EVENT: PUBLICATION YEAR OF 2008. BATCH #: UNK. THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE MANUFACTURING RECORDS CANNOT BE REVIEWED AS THE LOT/BATCH NUMBER HAS NOT BEEN PROVIDED.
TITLE: THE USE OF ¿HARMONIC SCALPEL¿ VERSUS ¿KNOT TYING¿ FOR CONVENTIONAL ¿OPEN¿ THYROIDECTOMY: RESULTS OF A PROSPECTIVE RANDOMIZED STUDY. AUTHORS: CELESTINO PIO LOMBARDI, MARCO RAFFAELLI, AMERICO CICCHETTI, MARCO MARCHETTI, CARMELA DE CREA, ROSSELLA DI BIDINO, LUIGI ORAGANO, ROCCO BELLANTONE. CITATION: LANGENBECKS ARCH SURG (2008) 393:627¿631, DOI 10.1007/S00423-008-0380-9. THIS PROSPECTIVE RANDOMIZED STUDY AIMED TO EVALUATE THE EFFICIENCY, SAFETY, COST EFFECTIVENESS AND THE IMPACT ON THE SURGICAL OUTCOME OF THE UTILIZATION OF THE HARMONIC SCALPEL (HS) DURING CONVENTIONAL ¿OPEN¿ THYROIDECTOMY (CT). BETWEEN MARCH AND DECEMBER 2007, A TOTAL OF 200 PATIENTS SCHEDULED FOR CONVENTIONAL ¿OPEN¿ TOTAL THYROIDECTOMY (TT) WERE RANDOMLY ASSIGNED TO TT WITH THE USE OF HS (HS GROUP) (N=100 [N=25 MALE N=75 FEMALE, MEAN AGE OF 49.5 YEARS, RANGE 20-72]) OR WITH THE KNOT TYING TECHNIQUE (KT GROUP) (N=100[N=22 MALE N=78 FEMALE, MEAN AGE OF 52.5, RANGE 25-74]). IN PATIENTS OF THE KT GROUP, THE UPPER, MIDDLE AND INFERIOR VESSELS WERE DIVIDED AFTER BEING TIED WITH CONVENTIONAL LIGATURES (POLYGLACTIN 910, 2/0 AND 3/0 AS REQUIRED; VICRYL, ETHICON ENDO-SURGERY). IN PATIENTS OF THE HS GROUP, DIVISION OF THE UPPER, MIDDLE AND INFERIOR VESSELS WAS OBTAINED WITH THE OPEN SHEAR SCISSOR GRIP CS-14C (HARMONIC, ETHICON ENDO-SURGERY), WHERE ACTIVE SHEAR IS UP AND THE INACTIVE SHEAR NEAR THE TISSUE TO INSURE MINIMAL THERMAL INJURY. COMPLAINT INCLUDED BLEEDING (N=1 HS GROUP, N=1 KT GROUP) AND TRANSIENT RECURRENT NERVE PALSY (N=2 HS GROUP, N=1 KT GROUP). PATIENTS WHO HAD BLEEDING COMPLICATIONS REQUIRED RE-OPERATION. HS IS A SAFE, EFFICACIOUS AND COST-EFFECTIVE ALTERNATIVE TO KNOT TYING TECHNIQUE FOR CT, ALLOWING FOR A SIGNIFICANT REDUCTION OF OPERATIVE TIME (ABOUT 30%) WITHOUT INCREASING COMPLICATIONS RATE AND OVERALL COSTS OF THE PROCEDURE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1181203 | HARMONIC SCALPEL CURVED SHEARS | INSTRUMENT, ULTRASONIC SURGICAL | GEI | ETHICON ENDO-SURGERY, LLC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Hospitalization |