FDA Adverse Event Malfunction Summary report: N

MAYFIELD TRIAD SKULL CLAMP

MDR report key: 9348677 · Received November 20, 2019

Report

Report Number
3004608878-2019-01097
Event Type
Malfunction
Date Received
November 20, 2019
Report Date
October 24, 2019
Manufacturer
INTEGRA LIFESCIENCES CORPORATION OH/USA
Product Code
HBL
PMA / PMN Number
PRE-AMEND
Product Problem
Yes
Report Source
Manufacturer report
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 0

ADDITIONAL INFORMATION WAS RECEIVED FROM THE DISTRIBUTOR ON 05DEC2019 INDICATING THAT "CONTRARY TO THE INFORMATION INITIALLY PROVIDED, THIS MAYFIELD TRIAD SKULL CLAMP DIDN¿T CAUSE SCALP LACERATION, ONLY THE FALL OF THE PATIENT'S HEAD. SO, THE REACTION OF THE SURGEON LIMITED THE GRAVITY OF THE INCIDENT; NO SCALP INJURY TO THE PATIENT WAS FINALLY OBSERVED." BETWEEN 05NOV2019 AND 30JUN2020, APPROXIMATELY 2,200 MDRS SUBMITTED ELECTRONICALLY BY INTEGRA LIFESCIENCES VIA TRACKWISE, INTEGRA'S COMPLAINT HANDLING SYSTEM, WERE NOT RECEIVED BY CDRH DUE TO A COMPUTER SYSTEM ISSUE. WITHIN THIS TIME PERIOD, AN ERROR WITH INTEGRA'S MIDDLEWARE, WHICH FACILITATES COMMUNICATIONS BETWEEN TRACKWISE AND THE FDA SYSTEM, CAUSED THE COMPLAINT RECORDS TO CLOSE AND INDICATE WE HAD RECEIVED AN ACKNOWLEDGEMENT 3 FROM THE FDA WHEN WE HAD NOT. INTEGRA INTERPRETED THE ACKNOWLEDGEMENT AS A SUCCESSFUL SUBMISSION; HOWEVER, SUBSEQUENT INVESTIGATION REVEALED THE ACKNOWLEDGEMENT 3 RECEIVED WAS FROM OUR MIDDLEWARE AND NOT FROM THE FDA (THESE ACKNOWLEDGEMENTS HAVE BEEN RETAINED AS PART OF THE DOCUMENTATION OF THE MDR). THE MALFUNCTION WAS RELATED TO THE RELOCATION OF THE TRACKWISE APPLICATION TO A NEW DATA CENTER DURING THE TRANSITION OF INTEGRA'S CORPORATE HEADQUARTERS FROM PLAINSBORO, NJ TO PRINCETON, NJ. PREVIOUSLY, INTEGRA HAD BEEN SUCCESSFULLY RECEIVING ACKNOWLEDGEMENTS 1, 2, AND 3 FROM THE FDA, AND OUR RECORDS REFLECT THESE ACKNOWLEDGEMENTS, INCLUDING THE DATE AND TIME STAMPS. CAPA PR 229048 AND NC 20-011 HAVE BEEN OPENED BY INTEGRA TO FURTHER INVESTIGATE THE NONCONFORMANCE AND DEVELOP A CORRECTIVE ACTION PLAN. THE MIDDLEWARE ERROR HAS BEEN CORRECTED, AND INTEGRA HAS FILED MDRS SINCE THE CORRECTION AND VERIFIED THAT THE APPROPRIATE ACKNOWLEDGEMENTS HAVE BEEN RECEIVED FROM THE FDA. INTEGRA IS RESUBMITTING ALL IMPACTED MDR REPORTS FOR THE TIME PERIOD 05NOV2019 THROUGH 30JUN2020. INTEGRA LIFESCIENCES CONTACTED (B)(4), DIRECTOR OF REGULATORY PROGRAMS, OFFICE OF PRODUCT EVALUATION AND QUALITY AND (B)(4), ASSISTANT DIRECTOR, MDR TEAM, OFFICE OF PRODUCT EVALUATION AND QUALITY ON JULY 8-9, 2020 TO REPORT THESE ISSUES REGARDING MDR REPORTS.

Additional Manufacturer Narrative · 0

THE DEVICE WAS RETURNED FOR EVALUATION. THE DHR SHOWS NO ABNORMALITIES RELATED TO THE REPORTED FAILURE. THE REPORTED COMPLAINT IS NOT CONFIRMED FROM THE EVALUATION. THE ISSUE COULD NOT BE DUPLICATED. THE LOCKING MECHANISM HAS SOME MOVEMENT. SMALL PARTS ARE WORN AND NEED TO BE REPLACED. THE WRENCH WAS MISSING, AND THE UNIT WAS MARKED WITH INSTANCE NUMBER. THE UNIT PASSED THE FUNCTIONAL TEST. THE DEFINITE ROOT CAUSE OF THE REPORTED COMPLAINT CANNOT BE RELIABLY DETERMINED. BETWEEN 05NOV2019 AND 30JUN2020, APPROXIMATELY 2,200 MDRS SUBMITTED ELECTRONICALLY BY INTEGRA LIFESCIENCES VIA TRACKWISE, INTEGRA'S COMPLAINT HANDLING SYSTEM, WERE NOT RECEIVED BY CDRH DUE TO A COMPUTER SYSTEM ISSUE. WITHIN THIS TIME PERIOD, AN ERROR WITH INTEGRA'S MIDDLEWARE, WHICH FACILITATES COMMUNICATIONS BETWEEN TRACKWISE AND THE FDA SYSTEM, CAUSED THE COMPLAINT RECORDS TO CLOSE AND INDICATE WE HAD RECEIVED AN ACKNOWLEDGEMENT 3 FROM THE FDA WHEN WE HAD NOT. INTEGRA INTERPRETED THE ACKNOWLEDGEMENT AS A SUCCESSFUL SUBMISSION; HOWEVER, SUBSEQUENT INVESTIGATION REVEALED THE ACKNOWLEDGEMENT 3 RECEIVED WAS FROM OUR MIDDLEWARE AND NOT FROM THE FDA (THESE ACKNOWLEDGEMENTS HAVE BEEN RETAINED AS PART OF THE DOCUMENTATION OF THE MDR). THE MALFUNCTION WAS RELATED TO THE RELOCATION OF THE TRACKWISE APPLICATION TO A NEW DATA CENTER DURING THE TRANSITION OF INTEGRA'S CORPORATE HEADQUARTERS FROM PLAINSBORO, NJ TO PRINCETON, NJ. PREVIOUSLY, INTEGRA HAD BEEN SUCCESSFULLY RECEIVING ACKNOWLEDGEMENTS 1, 2, AND 3 FROM THE FDA, AND OUR RECORDS REFLECT THESE ACKNOWLEDGEMENTS, INCLUDING THE DATE AND TIME STAMPS. CAPA PR 229048 AND NC 20-011 HAVE BEEN OPENED BY INTEGRA TO FURTHER INVESTIGATE THE NONCONFORMANCE AND DEVELOP A CORRECTIVE ACTION PLAN. THE MIDDLEWARE ERROR HAS BEEN CORRECTED, AND INTEGRA HAS FILED MDRS SINCE THE CORRECTION AND VERIFIED THAT THE APPROPRIATE ACKNOWLEDGEMENTS HAVE BEEN RECEIVED FROM THE FDA. INTEGRA IS RESUBMITTING ALL IMPACTED MDR REPORTS FOR THE TIME PERIOD 05NOV2019 THROUGH 30JUN2020. INTEGRA LIFESCIENCES CONTACTED (B)(4), DIRECTOR OF REGULATORY PROGRAMS, OFFICE OF PRODUCT EVALUATION AND QUALITY AND (B)(4), ASSISTANT DIRECTOR, MDR TEAM, OFFICE OF PRODUCT EVALUATION AND QUALITY ON JULY 8-9, 2020 TO REPORT THESE ISSUES REGARDING MDR REPORTS.

Description of Event or Problem · 0

N/A.

Additional Manufacturer Narrative · 1

THE DEVICE WAS NOT YET RETURNED TO THE MANUFACTURER FOR ANALYSIS. THE PLANT INVESTIGATION IS IN PROGRESS AND A SUPPLEMENTAL MEDWATCH REPORT WILL BE SUBMITTED UPON COMPLETION OF THE INVESTIGATION.

Description of Event or Problem · 1

IT WAS REPORTED THAT THE A1108 MAYFIELD TRIAD SKULL CLAMP "GAVE IN" AFTER BEING FIXED ON THE FEMALE PATIENT (YEAR OF BIRTH: 1951), CAUSING SCALP INJURY. ADDITIONAL INFORMATION WAS RECEIVED ON 04NOV2019 FROM THE DISTRIBUTOR INDICATING THAT THE HEAD OF THE PATIENT SUDDENLY FELL DURING HEMOSTASIS OF AN INTRACRANIAL AND EXTRACRANIAL HYDERMOID PROCEDURE PERFORMED BY THE SURGEON. IT WAS REPORTED THAT THE QUICK REACTION OF THE SURGEON WAS CRUCIAL TO AVOID PATIENT INJURY (TO BE VERIFIED). THE EVENT LEAD TO AN INCREASE OF SURGERY TIME OF ABOUT ONE (1) HOUR. ADDITIONAL INFORMATION HAS BEEN REQUESTED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1142821 MAYFIELD TRIAD SKULL CLAMP SKULL CLAMPS AND HEADREST SYSTEMS HBL INTEGRA LIFESCIENCES CORPORATION OH/USA 100717

Patients

Seq Age Sex Outcome Treatment
1 68 YR