BD VACUTAINER® SST¿ BLOOD COLLECTION TUBES
Report
- Report Number
- 1024879-2019-01975
- Event Type
- Malfunction
- Date Received
- November 14, 2019
- Date of Event
- October 29, 2019
- Report Date
- March 5, 2020
- Manufacturer
- BECTON, DICKINSON & CO., (BD)
- Product Code
- JKA
- UDI-DI
- 50382903679862
- PMA / PMN Number
- BK050036
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
THE FOLLOWING FIELDS HAVE BEEN UPDATED WITH ADDITIONAL INFORMATION: AGE AT TIME OF EVENT: 25 YEARS. SEX: FEMALE.
H.6. INVESTIGATION: BD HAD NOT RECEIVED SAMPLES OR PHOTOS FROM THE CUSTOMER FACILITY FOR EVALUATION; THEREFORE, THE INVESTIGATION WAS LIMITED. A REVIEW OF THE DEVICE HISTORY RECORD WAS COMPLETED FOR THE INCIDENT LOT AND, BASED ON THIS REVIEW, ALL PRODUCT SPECIFICATIONS AND REQUIREMENTS FOR LOT RELEASE WERE MET; THERE WERE NO RELATED QUALITY NON-CONFORMANCES DURING MANUFACTURING OF THE PRODUCT. ERRONEOUS POTASSIUM RESULTS CAN BE CAUSED BY MANY SOURCES, INCLUDING CERTAIN PATIENT PATHOLOGICAL CONDITIONS, IMPROPER SPECIMEN COLLECTION, SPECIMEN PROCESSING, AND SPECIMEN TRANSPORT. SPECIMEN COLLECTION FACTORS THAT CAN CONTRIBUTE TO ERRONEOUS POTASSIUM RANGE FROM PROLONGED TOURNIQUET TIME AND IMPROPER VENIPUNCTURE TECHNIQUE TO TRANSFERRING A SAMPLE FROM A SYRINGE DRAW OR IV CATHETER. SPECIMEN PROCESSING FACTORS INCLUDE VIGOROUS MIXING OR SHAKING OF THE SPECIMEN, NOT ALLOWING THE SPECIMEN TO CLOT FOR THE RECOMMENDED AMOUNT OF TIME, PROLONGED CONTACT OF SERUM OR PLASMA WITH CELLS, AND EXPOSURE TO EXCESSIVE HEAT OR COLD. FINALLY, MECHANICAL TRAUMA AND OTHER ADVERSE CONDITIONS DURING TRANSPORT OF TUBES CAN RESULT IN ERRONEOUS POTASSIUM RESULTS.
IT WAS REPORTED THAT BD VACUTAINER® SST¿ BLOOD COLLECTION TUBES WERE GIVING ERRONEOUS RESULTS. THIS WAS DISCOVERED DURING USE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: MATERIAL NO. 367986, BATCH NO. 9172629. IT WAS REPORTED THAT THERE HAVE BEEN SEVERAL RESULTS WITH HIGH POTASSIUM. PR 3 OF 4: THIS RECORD FOR PT 3 OF 4. PT IDS TBD, SECOND OCCURRENCE ON (B)(6) 2019. THERE HAVE BEEN SEVERAL RESULTS WITH HIGH POTASSIUM.
IT WAS REPORTED THAT BD VACUTAINER® SST¿ BLOOD COLLECTION TUBES WERE GIVING ERRONEOUS RESULTS. THIS WAS DISCOVERED DURING USE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: MATERIAL NO. 367986 BATCH NO. 9172629. IT WAS REPORTED THAT THERE HAVE BEEN SEVERAL RESULTS WITH HIGH POTASSIUM. PR 3 OF 4: THIS RECORD FOR PT 3 OF 4. PT IDS TBD, SECOND OCCURRENCE ON 29-OCT-2019. THERE HAVE BEEN SEVERAL RESULTS WITH HIGH POTASSIUM.
A DEVICE EVALUATION AND/OR DEVICE HISTORY REVIEW IS ANTICIPATED, BUT IS NOT COMPLETE. UPON COMPLETION, A SUPPLEMENTAL REPORT WILL BE FILED.
IT WAS REPORTED THAT BD VACUTAINER® SST¿ BLOOD COLLECTION TUBES WERE GIVING ERRONEOUS RESULTS. THIS WAS DISCOVERED DURING USE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: MATERIAL NO. 367986, BATCH NO. 9172629. IT WAS REPORTED THAT THERE HAVE BEEN SEVERAL RESULTS WITH HIGH POTASSIUM. PR 3 OF 4: THIS RECORD FOR PT 3 OF 4. PT IDS TBD, SECOND OCCURRENCE ON (B)(6) 2019 THERE HAVE BEEN SEVERAL RESULTS WITH HIGH POTASSIUM.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1114313 | BD VACUTAINER® SST¿ BLOOD COLLECTION TUBES | BLOOD SPECIMEN COLLECTION DEVICE | JKA | BECTON, DICKINSON & CO., (BD) | 367986 | 9172629 | 50382903679862 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 25 YR | Other |