FDA Adverse Event Injury Summary report: N

SAPIEN VALVE UNKNOWN

MDR report key: 9282631 · Received November 5, 2019

Report

Report Number
2015691-2019-04109
Event Type
Injury
Date Received
November 5, 2019
Date of Event
September 25, 2019
Report Date
October 11, 2019
Manufacturer
EDWARDS LIFESCIENCES
Product Code
NPT
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
NY, US
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 0

CORRECTED DATA: F10, H6. REFERENCE CAPA-20-00141.

Additional Manufacturer Narrative · 1

THE DATE OF THE EVENT IS UNKNOWN; HOWEVER, THE INFORMATION WAS PRESENTED ON SEPTEMBER 25, 2019. THEREFORE, THE PRESENTATION DATE WAS USED AS THE OCCURRENCE DATE. IT IS UNKNOWN IF A SAPIEN, SAPIEN XT OR SAPIEN 3 VALVE WAS IMPLANTED. THE PMA NUMBERS ARE P110021 FOR SAPIEN, P130009 FOR SAPIEN XT AND P100041 FOR SAPIEN 3. PER THE INSTRUCTIONS FOR USE (IFU) CARDIOVASCULAR INJURY, SUCH AS PERFORATION DISSECTION OF VESSELS, VENTRICLE, MYOCARDIUM OR VALVULAR STRUCTURES, IS A KNOWN POTENTIAL COMPLICATION ASSOCIATED WITH THE TAVR PROCEDURE. ACCORDING TO THE THV TRAINING MANUALS, RISK FACTORS FOR AORTIC DISSECTION, HEMATOMA OR ANNULAR RUPTURE DURING THE TAVR PROCEDURE INCLUDE SIGNIFICANT THV OVER SIZING, SEVERELY OBLITERATED SINUSES OF VALSALVA, PORCELAIN AORTA AND/OR PRESENCE OF BULKY CALCIFICATION AND NARROW CALCIFIED STJ. IN ADDITION, ADVANCED AGE, FEMALE GENDER, SMALL BODY WEIGHT, AND STEROID DEPENDENCY CAN ALSO BE CONTRIBUTING FACTORS. THE SAPIEN VALVE RELIES ON NATIVE VALVE CALCIUM TO SECURELY ANCHOR TO THE ANNULUS. DESPITE THIS BENEFICIAL ASPECT OF CALCIUM, BULKY CALCIUM CAN INCREASE THE RISK OF CALCIFIC NODULE DISPLACEMENT INTO THE VASCULATURE, WHICH CAN LEAD TO VASCULAR INJURY. AT TIMES THE EXTENT AND DISTRIBUTION OF CALCIUM CAN IMPAIR EASE OF DELIVERY OF THE VALVE, CORRECT POSITIONING OF THE VALVE, DEPLOYMENT OF THE VALVE AND PROCEDURAL SUCCESS. IN THIS CASE, THERE WAS NO ALLEGATION OR INDICATION A DEVICE MALFUNCTION CONTRIBUTED TO THIS ADVERSE EVENT. THE CAUSE FOR THE ROOT RUPTURE COULD NOT BE DETERMINED WITH THE LIMITED INFORMATION PROVIDED BY THE AUTHOR. THE IFU AND TRAINING MANUALS HAVE BEEN REVIEWED AND NO INADEQUACIES HAVE BEEN IDENTIFIED WITH REGARDS TO WARNINGS, CONTRAINDICATIONS, AND THE DIRECTIONS/CONDITIONS FOR THE SUCCESSFUL USE OF THE DEVICE. COMPLAINT HISTORIES FOR ALL REPORTED EVENTS ARE REVIEWED AGAINST TRENDING CONTROL LIMITS ON A MONTHLY BASIS, AND ANY EXCURSIONS ABOVE THE CONTROL LIMITS ARE ASSESSED AND DOCUMENTED AS PART OF THIS MONTHLY REVIEW. NO CORRECTIVE OR PREVENTATIVE ACTIONS ARE REQUIRED.

Description of Event or Problem · 1

AS REPORTED THROUGH THE TCT 2019 CONFERENCE, POST IMPLANT OF A SAPIEN VALVE, THE PATIENT HAD A ROOT RUPTURE. THERE WAS NO ADDITIONAL INFORMATION PROVIDED BY THE AUTHORS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1071352 SAPIEN VALVE UNKNOWN AORTIC VALVE, PROSTHESIS, PERCUTANEOUSLY DELIVERED NPT EDWARDS LIFESCIENCES SAPIEN VALVE UNKNOWN

Patients

Seq Age Sex Outcome Treatment
1