FDA Adverse Event Malfunction Summary report: N

PEGASUS BL 22GA X 0.75IN QSYTE NON-PVC

MDR report key: 9280665 · Received November 5, 2019

Report

Report Number
3006948883-2019-00919
Event Type
Malfunction
Date Received
November 5, 2019
Date of Event
October 11, 2019
Report Date
December 13, 2019
Manufacturer
BD RAPIS DIAGNOSTICS (SUZHOU) CO. LTD.
Product Code
FOZ
PMA / PMN Number
PENDING
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CH
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

INVESTIGATION SUMMARY: A DEVICE HISTORY REVIEW WAS CONDUCTED FOR LOT NUMBER 8042416. OUR RECORDS SHOW THAT THIS IS THE ONLY INSTANCE OF THIS ISSUE OCCURRING IN THIS PRODUCTION BATCH. ACCORDING TO THE SAMPLING PLAN APPLIED FOR PRODUCT PERFORMANCE, THIS LOT WAS ACCEPTED AND RELEASED WITHOUT DEFECTS BEING NOTED DURING THE FINAL ASSEMBLY OR VISUAL INSPECTIONS. ADDITIONALLY, A SAMPLE WAS RECEIVED FOR THE PURPOSE OF OUR INVESTIGATION. OUR INVESTIGATORS NOTED A SMALL CRACK WAS FOUND DURING LEAKAGE TESTING THAT WAS LOCATED ON THE ADAPTER. THE RETURNED PRODUCT'S SWAGE DIMENSIONS WERE MEASURED BY OUR TEAM AND FOUND TO BE WITHIN PRODUCT SPECIFICATIONS. HOWEVER ACCORDING TO PREVIOUS INVESTIGATIONS, THROUGH A VARIANCE IN THE AUTOLINE'S SWAGE PRESSURE IT IS POSSIBLE FOR THE MACHINE TO APPLY EXCESS FORCE TO THE DEVICE DURING ASSEMBLY, ALLOWING FOR THE RESULTING CRACK TO FORM IN THE DEVICE. CURRENTLY, WE ARE CONDUCTING A LONG TERM STUDY TO DETERMINE THE ROOT CAUSE FOR THIS EVENT, BUT WE ARE ADDRESSING THE ISSUE THROUGH THE IMPLEMENTATION OF MANUAL INSPECTIONS FOR CRACKS IN THE ADAPTER HEAD, AND WE ARE FURTHER OPTIMIZING OUR SWAGING PROCESS BY REDUCING DEPTH REQUIREMENTS.

Description of Event or Problem · 0

IT WAS REPORTED THAT THE PEGASUS BL 22GA X 0.75IN QSYTE NON-PVC EXPERIENCED LEAKAGE AT ADAPTER AND TUBING DURING USE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: IT'S NOTICED THAT LEAKAGE BETWEEN EXT. TUBING ND ADAPTER AFTER COMPLETE PENETRATION.

Additional Manufacturer Narrative · 1

A DEVICE EVALUATION IS ANTICIPATED, BUT HAS NOT YET BEGUN. UPON COMPLETION OF THE INVESTIGATION, A SUPPLEMENTAL REPORT WILL BE FILED.

Description of Event or Problem · 1

IT WAS REPORTED THAT THE PEGASUS BL 22GA X 0.75IN QSYTE NON-PVC EXPERIENCED LEAKAGE AT ADAPTER AND TUBING DURING USE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: IT'S NOTICED THAT LEAKAGE BETWEEN EXT. TUBING ND ADAPTER AFTER COMPLETE PENETRATION.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
1071042 PEGASUS BL 22GA X 0.75IN QSYTE NON-PVC INTERVASCULAR CATHETER FOZ BD RAPIS DIAGNOSTICS (SUZHOU) CO. LTD. 8042416

Patients

Seq Age Sex Outcome Treatment
1 Other