LOCKING SCREWDRIVER BODY
Report
- Report Number
- 1818910-2019-111540
- Event Type
- Malfunction
- Date Received
- October 23, 2019
- Date of Event
- October 2, 2019
- Report Date
- October 2, 2019
- Manufacturer
- DEPUY FRANCE SAS - 3003895575
- Product Code
- HXX
- UDI-DI
- 10603295116561
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- AS
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
PRODUCT COMPLAINT # (B)(4). DEPUY SYNTHES IS SUBMITTING THIS REPORT PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH DEPUY SYNTHES HAS NOT BEEN ABLE TO INVESTIGATE OR VERIFY PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY FDA, DEPUY SYNTHES OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE DEVICE, DEPUY SYNTHES, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. INVESTIGATION SUMMARY: EXAMINATION OF THE DEVICE CONFIRMED THE FAILURE MODE AS REPORTED: THE PEG HAS BROKEN OFF. ROOT CAUSE ATTRIBUTED TO PRODUCT DESIGN. DEPUY SYNTHES CONSIDERS THE INVESTIGATION CLOSED AT THIS TIME. SHOULD ADDITIONAL INFORMATION BE RECEIVED, THE INFORMATION WILL BE REVIEWED AND THE INVESTIGATION MAY BE RE-OPENED AS NECESSARY. INVESTIGATION METHODS: WAS PATIENT AFFECTED: NO. DEVICE HISTORY REVIEWED: NO. LOT TRACE OBTAINED: NO. COMPLAINTS DATABASE SEARCHED: YES. PRODUCT CHECKED: YES. LABEL CHECKED: NO. PRODUCT PULLED FROM STOCK FOR INSPECTION: NO. A REVIEW OF COMPLAINT DATABASES IDENTIFIED SIMILAR COMPLAINTS. EXAMINATION OF THE DEVICE CONFIRMED THE FAILURE MODE AS REPORTED- THE PEG HAS BROKEN OFF. PREVIOUS INVESTIGATIONS IDENTIFIED A TREND FOR THE TEETH BREAKING. A HEALTH HAZARD EVALUATION MEETING WAS CONDUCTED ON JULY 2, 2013 AND IDENTIFIED A POTENTIAL HARM, AS DOCUMENTED IN (B)(4) VIA ECO 437762, WHICH WAS COMPLETED ON SEPTEMBER 25, 2013. THE ISSUE AND HARM WERE FORWARDED TO THE QUALITY REVIEW BOARD VIA (B)(4) ON JULY 15, 2013, AND IT WAS DETERMINED THAT A FIELD ACTION WAS NOT NECESSARY DUE TO THE LOW OCCURRENCE RATE. MDD CAPA-001649 WAS INITIATED ON JULY 19, 2013 TO DETERMINE ROOT CAUSE AND CORRECTIVE ACTIONS NEEDED. A SALES MAIL WAS ISSUED TO THE US SALES FORCE ON 10/01/2013 TITLED "LOCKING SCREWDRIVER TECHNIQUE REMINDER" TO REINFORCE THE PROPER USE OF THE DRIVER (E.G. KEEPING THE DRIVER IN AXIAL ALIGNMENT WITH THE SCREW AND USING THE DRIVER SLEEVE). THESE ITEMS ARE ALREADY CONTAINED IN THE SURGICAL TECHNIQUE. CAPA-001649 WAS CLOSED ON MAY 9, 2016, IDENTIFYING THE ROOT CAUSE TO BE INADEQUATE DESIGN. THE ACTIONS IMPLEMENTED AS A RESULT OF THIS CAPA HAVE ADDRESSED THE ROOT CAUSE OF INADEQUATE DESIGN. THE REDESIGN OF THE DELTA EXTEND SCREWDRIVER GUIDE ENSURE THAT THE SCREWS ARE CAPTURED PROPERLY AND TORQUED "ON-AXIS," THUS PREVENTING OVERLOADING OF THE TEETH IN THE SCREWDRIVER, WHICH COULD RESULT IN THE FRACTURING OF THE TEETH AS SEEN IN THE INITIAL COMPLAINTS. THE MATERIAL CHANGE FROM 455 STAINLESS TO 465 STAINLESS RESULTED IN A MORE RESILIENT DEVICE AND ONE IN WHICH THE FAILURE MODE CHANGED FROM FRACTURE (OF THE TEETH) TO DEFORMATION. CO (B)(4) WAS CREATED TO CHANGE THE MATERIAL FROM 455 STAINLESS TO 465 STAINLESS RESULTED IN A MORE RESILIENT DEVICE AND ONE IN WHICH THE FAILURE MODE CHANGED FROM FRACTURE (OF THE TEETH) TO DEFORMATION. THE CURRENT COMPLAINT SAMPLE DEVICE WAS MANUFACTURED PRIOR TO THE RELEASE OF CO (B)(4). THE COMPLAINT SHALL BE CLOSED WITH A JUSTIFIED CONCLUSION; ENTERED INTO THE COMPLAINTS DATABASE AND MONITORED THROUGH TREND ANALYSIS. POST MARKET SURVEILLANCE IS PER SEP 419.
PRODUCT COMPLAINT # (B)(4). IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.
SURGEON WAS SCREWING IN LOCKING SCREWS AND BROKE ONE OF THE 4 FINS ON THE SCREWDRIVERS. WAS ABLE TO COMPLETE THE SURGERY WITH THIS SCREWDRIVER. WHEN CHECKING THE REPLACEMENT SCREWDRIVER ON SHELF AT THE HOSPITAL TO REPLACE THIS ONE IT WAS IDENTIFIED THAT THIS ONE ALSO HAD A FIN BROKEN ON IT. THERE WAS NO DELAY IN SURGERY. METAL PIECE RECOVERED AND DISPOSED OF.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1018491 | LOCKING SCREWDRIVER BODY | EXTREMITY INSTRUMENTS : SCREWDRIVERS | HXX | DEPUY FRANCE SAS - 3003895575 | 5293179 | 10603295116561 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |