RESOLUTE INTEGRITY RX
Report
- Report Number
- 9612164-2019-04135
- Event Type
- Injury
- Date Received
- September 30, 2019
- Date of Event
- March 26, 2019
- Report Date
- September 30, 2019
- Manufacturer
- MEDTRONIC IRELAND
- Product Code
- NIQ
- PMA / PMN Number
- P110013
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- JA
- Reporter Occupation
- PHYSICIAN
Narratives
JOURNAL TITLE: RECURRENT CORONARY THROMBUS IN PATIENT WITH CHRONIC IMMUNE THROMBOCYTOPENIA WITH TREATMENT USING ELTROMBOPAG. DATE OF PUBLICATION DOI.ORG/10.1155/2019/2756319. IMAGE REVIEW: CAG ( CORONARY ANGIOGRAPHY) ELECTROCARDIOGRAPHY (ECG) AND CARDIAC MAGNETIC RESONANCE IMAGING (C-MRI) WERE PROVIDED OF THE FIRST ADMISSION OF THE PATIENT SHOWING NO SIGNIFICANT CHANGE EXCEPT A LEFT AXIS DEVIATION, NO CORONARY ARTERY OCCLUSION EITHER IN THE RCA OR LCA AND DELAYED ENHANCEMENT OF THE MYOCARDIUM. CAG AND INTRAVASCULAR ULTRASOUND IMAGES PROVIDED AFTER IMPLANTATION OF THE RESOLUTE INTEGRITY STENT DURING THE FIRST PCI SHOW A MASSIVE THROMBUS IN THE STENT LESION. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.
IT WAS REPORTED IN JOURNAL THAT A CASE STUDY PATIENT WAS ADMITTED TO HOSPITAL WITH SEVERE CHEST PAIN. CARDIAC CATHETERIZATION WAS PERFORMED URGENTLY DUE TO INCREASE OF SERUM MYOCARDIAL ENZYMES. CAG REVEALED NO ARTERY OCCLUSION, LEFT VENTRICULOGRAPHY SHOWED MILD HYPOKINESE IN THE POSTERIOR WALL AND CARDIAC MAGNETIC RESONANCE IMAGING SUGGESTED MI OF THE TERRITORY OF THE LCX. PATIENT WAS DISCHARGED BUT COMPLAINED OF CHEST PAIN POST DISCHARGE. 3 MONTHS LATER THE PATIENT RETURNED AND CAG REVEALED NEW STENOSIS IN THE OM BRANCHES AND ADENOSINE STRESS MYOCARDIAL ISCHEMIA OF THE POSTERIOR WALL. A RESOLUTE INTEGRITY RX DRUG ELUTING STENT WAS IMPLANTED IN THE OM BRANCH SUCCESSFULLY WITH NO RESIDUAL STENOSIS. 3 HOURS AFTER PCI, PATIENT EXPERIENCED SEVERE CHEST PAIN WITH SIGNIFICANT ST DEPRESSION. CAG WAS CARRIED OUT AND STENT THROMBOSIS WAS NOTED AT THE PROXIMAL EDGE OF THE STENT. A NON-MEDTRONIC STENT WAS IMPLANTED AT THE PROXIMAL EDGE OF THE RESOLUTE INTEGRITY. ANTIPLATELET WAS CHANGED FROM CLOPIDOGREL TO PRASUGREL TO AVOID FURTHER STENT THROMBOSIS. 3 DAYS LATER FURTHER CAG REVEALED A MASSIVE THROMBUS WITH 75% STENOSIS IN THE OM BRANCH VESSEL. UROKINASE WAS INJECTED INTO THE LC X INSTEAD OF BALLOON PCI . FURTHER CAG SHOWED A REDUCTION OF STENOSIS TO 50%. 14 DAYS LATER CAG REVEALED THE RECURRENCE OF THROMBUS AND 75% STENOSIS. CORONARY THROMBOSIS ASPIRATION WAS PERFORMED AS 4TH PCI. THE PATIENT ALSO UNDERWENT A SPLENECTOMY TO TACKLE ELTROMBOPAG WHICH WAS SUSPECTED AS HAVING AN ASSOCIATION WITH THE RECURRENCE OF THROMBOSIS. AFTER THE PROCEDURE, THE PATIENT HAS HAD NO COMPLAINTS OF CHEST PAIN AND FOLLOW UP CAG SHOWED NO THROMBUS IN THE TREATED VESSEL.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 928469 | RESOLUTE INTEGRITY RX | STENT, CORONARY, DRUG-ELUTING | NIQ | MEDTRONIC IRELAND |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 67 YR | Required Intervention |