FDA Adverse Event Injury Summary report: N

ENDURANT STENT GRAFT

MDR report key: 9123637 · Received September 26, 2019

Report

Report Number
9612164-2019-04106
Event Type
Injury
Date Received
September 26, 2019
Date of Event
August 29, 2019
Report Date
September 26, 2019
Manufacturer
MEDTRONIC IRELAND
Product Code
MIH
PMA / PMN Number
P100021
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
GR
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

MEDTRONIC RECEIVED THE FOLLOWING INFORMATION FROM THE JOURNAL ARTICLE ENTITLED; CORRELATION OF BASELINE PLASMA AND INGUINAL CONNECTIVE TISSUE METALLOPROTEINASES AND THEIR INHIBITORS WITH LATE HIGH-PRESSURE ENDOLEAK AFTER ENDOVASCULAR ANEURYSM REPAIR: LONG-TERM RESULTS. GEORGE S. GEORGIADIS, GEORGE A. ANTONIOU, CHRISTOS ARGYRIOU, NIKOLAOS SCHORETSANITIS, EVAGGELOS NIKOLOPOULOS, KONSTANTINOS KAPOULAS, MILTOS K. LAZARIDES, AND IOANNIS TENTES. JOURNAL OF ENDOVASCULAR THERAPY 2019 HTTPS://DOI.ORG/10.1177/152660281987196. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.

Description of Event or Problem · 1

ENDURANT STENT GRAFTS WERE IMPLANTED IN PATIENT FOR ENDOVASCULAR ANEURYSM REPAIR. THE FOLLOWING EVENTS WERE REPORTED: SERIOUS INJURY: RUPTURE INFECTION MULTI-ORGAN FAILURE RE-INTERVENTION ABSTRACT PURPOSE: TO INVESTIGATE WHETHER PLASMA AND CONNECTIVE TISSUE MATRIX METALLOPROTEINASES (MMP) AND THEIR INHIBITORS (TIMP) MAY PREDICT LATE HIGH-PRESSURE ENDOLEAK AFTER ENDOVASCULAR ANEURYSM REPAIR (EVAR). MATERIALS AND METHODS: SAMPLES OF INGUINAL FASCIA AND BLOOD WERE COLLECTED IN 72 CONSECUTIVE PATIENTS (MEAN AGE 73.1 YEARS; 68 MEN) UNDERGOING PRIMARY EVAR WITH THE ENDURANT STENT-GRAFT. BASELINE PLASMA LEVELS OF MMP-2, MMP-9, TIMP-1, AND TIMP-2 AND BASELINE MMP-2 AND MMP-9 ACTIVITY ESTIMATED USING GELATIN ZYMOGRAPHY (GZ) WERE COMPARED BETWEEN PATIENTS WHO DEVELOPED LATE ENDOLEAK IN FOLLOW-UP AND THOSE WHO DID NOT. SUBGROUP ANALYSES WERE PERFORMED BETWEEN PATIENTS WITH (N=18) AND WITHOUT INGUINAL HERNIAS AND BETWEEN PATIENTS WITH MODERATE-DIAMETER (50¿59 MM; N=45) OR LARGE-DIAMETER (=60 MM; N=27) ABDOMINAL AORTIC ANEURYSMS (AAA) AT PRIMARY EVAR. RESULTS: THE MEAN FOLLOW-UP PERIOD WAS 63.1 MONTHS (RANGE 7.5¿91.5), DURING WHICH TIME 13 (18.1%) PATIENTS DEVELOPED TYPE I (6 IA AND 5 IB) OR 2 TYPE III ENDOLEAKS. ONLY GZ-ANALYZED PROMMP-9 CONCENTRATIONS WERE HIGHER IN THE ENDOLEAK GROUP THAN IN PATIENTS WITHOUT ENDOLEAK (MEAN DIFFERENCE 8.44, 95% CI -19.653 TO -1.087, P=0.03). THE PATIENTS WITH PRIMARY INGUINAL HERNIA AT PRESENTATION HAD SIGNIFICANTLY HIGHER TISSUE TIMP-2 VALUES (0.8±0.7 VS 0.5±0.4, P=0.018) BUT LOWER PLASMA TOTAL (PRO- + ACTIVE) MMP-9 VALUES (11.9±7.8 VS 16.2±7.4, P=0.042) THAN PATIENTS WITHOUT HERNIAS AT THE TIME OF EVAR. PATIENTS WITH AAAS =60 MM HAD SIGNIFICANTLY HIGHER MEAN TISSUE HOMOGENATE LEVELS OF TOTAL (PRO- + ACTIVE) MMP-9 (P=0.025) AND TOTAL (PRO- + ACTIVE) MMP-2 (P=0.049) AS WELL AS HIGHER PROMMP-9 (P=0.018) AND TOTAL (PRO- + ACTIVE) MMP-9 (P=0.021) LEVELS BASED ON GZ COMPARED TO PATIENTS WITH MODERATE-DIAMETER AAAS. REGRESSION ANALYSIS REVEALED A SIGNIFICANT ASSOCIATION BETWEEN TOTAL (PRO + ACTIVE) MMP-9 PLASMA SAMPLES AND THE PRESENCE OF HERNIA (OR 0.899, 95% CI 0.817 TO 0.989, P=0.029) AND BETWEEN GZ-ANALYZED PROMMP-9 AND LATE ENDOLEAK (OR 1.055, 95% CI 1.007 TO 1.106, P=0.025). GZ-A NALYZED PROMMP-9 AND ACTIVE MMP-9 WERE STRONG PREDICTORS OF LATE ENDOLEAK IN PATIENTS WITH HERNIA (P=0.012 AND P=0.044, RESPECTIVELY) AND IN PATIENTS WITH AAAS =60 MM (P=0.018 AND P=0.041 RESPECTIVELY). CONCLUSION: INGUINAL FASCIAL TISSUE PROMMP-9 SIGNIFICANTLY PREDICTED LATE ENDOLEAK. PROMMP-9 AND ACTIVE MMP-9 BIOMARKERS ARE SIGNIFICANTLY ASSOCIATED WITH LATE ENDOLEAK IN HERNIA PATIENTS AND IN PATIENTS WITH AAAS =60 MM. CONSIDERING THE CLINICAL ASSOCIATION BETWEEN HERNIA AND AAA AND THE FACT THAT THE AAA WALL CONNECTIVE TISSUE ENVIRONMENT REMAINS EXPOSED TO SYSTEMIC CIRCULATION AFTER EVAR, INGUINAL FASCIA EXTRACELLULAR MATRIX DYSREGULATION AND ALTERED MMP ACTIVITY MAY REFLECT SIMILAR CHANGES IN AAA BIOLOGY, LEADING TO COMPLICATIONS SUCH AS ENDOLEAK.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
917077 ENDURANT STENT GRAFT SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT MIH MEDTRONIC IRELAND

Patients

Seq Age Sex Outcome Treatment
1 73 YR Required Intervention