LIGACLIP MULTIPLE CLIP APPLIER
Report
- Report Number
- 1527736-1997-00918
- Event Type
- Malfunction
- Date Received
- May 13, 1997
- Report Date
- May 12, 1997
- Manufacturer
- LACEY MANUFACTURING CO.
- Product Code
- GDO
- Removal / Correction Number
- NA
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- MX
- Reporter Occupation
- PHYSICIAN
Narratives
DEVICE #2: H6; DAMAGED ANTI-BACKUP. PRODUCT COMPLAINT ANALYSIS TEAM HAS COMPLETED ITS INVESTIGATION OF DEVICE WHICH WAS RETURNED. RESULTS OF INVESTIGATION CONDUCTED BY APPROPRIATE ENGINEERS AND TECHNICIANS ARE LISTED BELOW. VISUAL INSPECTIONS & RESULTS: BODY ASSEMBLY BOWED, AB)NO; CLIP IN JAW, A)NO B)YES; CLIP STACK PRESSURE, AB)GOOD; CLIP STAGING, A)N/A B)GOOD; CLIP TRACK LOCATION, AB)GOOD; CONDITION OF CARTRIDGE COVER TABS, AB)GOOD AND TOTAL # CLIPS REMAINING, A)0 B)7. FUNCTIONAL TESTS & RESULTS: ANTI-BACKUP FUNCTIONAL, A)N/A B)NO/STRIPPED; CLIPS FORM PROPERLY, A)N/A B)YES; CLIP FEED PROPERLY, A)N/A B)YES; CYCLE APPLIER, A)NO B)YES AND LOCKOUT FUNCTIONAL, AB)YES. ANALYSIS CONCLUSION: AB)BASED UPON INQUIRY INFO RECEIVED, VISUAL EXAMINATION AND FUNCTIONAL TEST; A)NO CONCLUSION COULD BE REACHED AS TO WHAT MAY HAVE CAUSED REPORTED INCIDENT DURING SURGERY. APPLIER WAS RECEIVED EMPTY AND LOCKED OUT AND NO FUNCTIONAL TESTING COULD BE PERFORMED. APPLIER WAS EXAMINED AND WAS FOUND TO BE WITHIN DESIGN SPECIFICATIONS. B)IT WAS CONCLUDED THAT REPORTED INCIDENT MAY HAVE BEEN CAUSED BY STRIPPED PAWL. APPLIER WAS CYCLED, AND PAWL WAS OBSERVED TO BE STRIPPED, BUT FIRED AND PROPERLY FORMED REMAINING 7 CLIPS. NO CONCLUSION COULD BE REACHED AS TO HOW PAWL HAD BECOME STRIPPED. A)EACH INSTRUMENT IS EVALUATED DURING ASSEMBLY PROCESS TO ENSURE THAT IT FUNCTIONS PROPERLY. B)IF FIRING HANDLES ARE FORCED OPEN BEFORE FIRING STROKE IS COMPLETED, PAWL WILL BECOME STRIPPED. INSTRUMENT MUST BE FIRED UNTIL HANDLES MEET BODY ASSEMBLY TO ENSURE CLIPS BEING APPLIED IS FULLY FORMED. AFTER FIRING STROKE IS COMPLETED, HANDLES WILL RETURN TO OPEN POSITION.
DURING AN UNKNOWN PROCEDURE, IT WAS REPORTED BY THE AFFILIATE THAT THE CLIPS DID NOT CLOSE WITH ENOUGH PRESSURE TO AVOID THE BLOOD FLUX. THERE WAS NO PT CONSEQUENCE.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 1 | LIGACLIP MULTIPLE CLIP APPLIER | CLIP APPLIER | GDO | LACEY MANUFACTURING CO. | NA | K46221 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | UNKNOWN | Other |