FDA Adverse Event Injury Summary report: N

MEDTRONIC NAVIGATION

MDR report key: 9035849 · Received September 13, 2019

Report

Report Number
1723170-2019-04871
Event Type
Injury
Date Received
September 13, 2019
Date of Event
September 22, 2018
Report Date
September 13, 2019
Manufacturer
MEDTRONIC NAVIGATION, INC
Product Code
HAW
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
CA
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

PATIENT AGE IS THE MEAN VALUE OF ALL PATIENTS IN THE STUDY. PATIENT GENDER IS THE MAJORITY VALUE OF PATIENTS IN THE STUDY. PATIENT WEIGHT IS THE MEAN VALUE OF ALL PATIENTS IN THE STUDY. DEVICE LOT NUMBER, OR SERIAL NUMBER, UNAVAILABLE. 510(K) OF THE PRODUCT IS UNAVAILABLE AS THE SERIAL NUMBER OF THE NAVIGATION SYSTEM WAS NOT PROVIDED. NO PARTS HAVE BEEN RECEIVED BY THE MANUFACTURER FOR EVALUATION. DEVICE MANUFACTURING DATE IS DEPENDENT ON LOT NUMBER/SERIAL NUMBER, THEREFORE, UNAVAILABLE. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED. (B)(4).

Description of Event or Problem · 1

CITATION: JONATHAN BOURGET-MURRAY, MD, CM, GARIELLE E. BROWN, BSC, MSC. ALEJANDRO PEIRO-GARCIA, MD, MADALENE A. EARP, PHD, DAVID L. PARSONS, MD, FRCSC, F ABIO FERRI-DE-BARROS, MD, MSC, FSBOT, FRCSC. QUALITY, SAFETY, AND VALUE OF INNOVATING CLASSIC OPERATIVE TECHNIQUES IN SCOLIOSIS SURGERY: INTEROPERATIVE TRACTION AND NAVIGATED SEQUENTIAL DRILLING. OBJECTIVES: THIS STUDY AIMS TO MEASURE AND DESCRIBE THE CLINICAL AND FINANCIAL IMPLICATIONS OF THE SYSTEMATIC IMPLEMENTATION OF INTRAOPERATIVE SKULL-FEMORAL TRACTION (IOSFT) AND NAVIGATED SEQUENTIAL DRILLING (NSD) FOR POSTERIOR SPINAL INSTRUMENTATION AND FUSION (PSIF) IN ADOLESCENT IDIOPATHIC SCOLIOSIS (AIS) AT OUR INSTITUTION. SUMMARY OF BACKGROUND DATA: PSIF HAS BEEN THE STANDARD SURGICAL TREATMENT FOR AIS. THIS RETROSPECTIVE SINGLE-CENTER QUALITY IMPROVEMENT STUDY DESCRIBES THE PERIOPERATIVE OUTCOMES AND IMPACT ON HEALTH RESOURCE UTILIZATION FOLLOWING THE SYSTEMATIC APPLICATION OF TWO CLASSIC SURGICAL STRATEGIES MODIFIED USING CURRENT TECHNOLOGY: IOSFT AND NSD. METHODS: WE REVIEWED THE MEDICAL RECORDS OF 125 PATIENTS WHO UNDERWENT A SINGLE-STAGE PSIF FOR AIS. WE IDENTIFIED THREE COHORTS BASED ON SURGICAL STRATEGIES USED INTRAOPERATIVELY. TRADITIONAL TECHNIQUES (N 5 28), IOSFT (N 5 45), AND IOSFT PLUS NSD (N 5 52). THE PRIMARY OUTCOME MEASURES WERE OPERATIVE TIME, PREVALENCE OF CASES REQUIRING EXTENDED OPERATING ROOM TIME, NEED FOR BLOOD TRANSFUSION, LENGTH OF HOSPITAL STAY, AND COST PER SURGERY. SECONDARY OUTCOMES INCLUDED IMPLANT DENSITY, DEGREE OF SPINE DEFORMITY CORRECTION, AND PERIOPERATIVE COMPLICATIONS. RESULTS: ALL PRIMARY OUTCOME MEASURES IMPROVED SIGNIFICANTLY (P ! .001). MEDIAN OPERATING TIME DECREASED BY 59%. USE OF LATE OPERATING ROOM HOURS FELL FROM 89% TO 0% AND TRANSFUSION RATES FROM 64% TO 1.9%. LENGTH OF HOSPITAL STAY DECREASED FROM 6 TO 4 DAYS. COMPREHENSIVE COST PER CASE DECREASED BY 24%. DISCUSSION: TOGETHER, IOSFT AND NSD IMPROVED THE QUALITY, SAFETY, AND VALUE OF CARE. THESE SURGICAL STRATEGIES WERE PERFORMED WITHOUT INCREASED PERIOPERATIVE COMPLICATIONS, WHILE REDUCING COST PER CASE BY 24%. CONCLUSIONS: THE DATA PRESENTED MAY HAVE SIGNIFICANT IMPLICATIONS IN HEALTH RESOURCE UTILIZATION FOR AIS SURGERY. REPORTED EVENTS: ONE PATIENT IN COHORT A EXPERIENCED A TEMPORARY DROP IN MOTOR EVOKED POTENTIALS (MEPS) DURING THE MAIN CORRECTION. THE MEPS WERE NOTED TO FULLY RECOVER WITH THE RELEASE OF THE CORRECTION. THE PATIENT WAS NOTED TO HAVE NORMAL NEUROLOGIC EXAMINATIONS POST-OPERATIVE. ONE PATIENT IN COHORT B EXPERIENCED A TEMPORARY DROP IN MOTOR EVOKED POTENTIALS (MEPS) DURING THE MAIN CORRECTION. THE MEPS WERE NOTED TO FULLY RECOVER WITH THE RELEASE OF THE CORRECTION. THE PATIENT WAS NOTED TO HAVE NORMAL NEUROLOGIC EXAMINATIONS POST-OPERATIVE. THREE PATIENTS REQUIRED REVISION SURGERY DUE TO ADDING ON PHENOMENA LEADING TO CORONAL DECOMPENSATION FOLLOWING SELECTIVE LUMBAR FUSIONS. THREE PATIENTS REQUIRED REVISION SURGERY DUE TO SYMPTOMATIC PROMINENT IMPLANTS. ONE PATIENT REQUIRED REVISION SURGERY DUE TO A BROKEN PEDICLE SCREW. ONE PATIENT REQUIRED REVISION SURGERY DUE TO A LATE INFECTION.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
812230 MEDTRONIC NAVIGATION INSTRUMENT, STEREOTAXIC HAW MEDTRONIC NAVIGATION, INC UNK_NAV_SYS

Patients

Seq Age Sex Outcome Treatment
1 15 YR Required Intervention