TECNIS SYMFONY TORIC
Report
- Report Number
- 9614546-2019-00846
- Event Type
- Injury
- Date Received
- September 10, 2019
- Report Date
- November 10, 2020
- Manufacturer
- JOHNSON & JOHNSON SURGICAL VISION, INC.
- Product Code
- POE
- PMA / PMN Number
- P980040
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- KR
- Reporter Occupation
- PHYSICIAN
Narratives
THIS CORRECTION MDR IS BEING SUBMITTED TO ADDRESS INACCURATE INFORMATION IN SECTION F ON THE XML VERSION OF THE PREVIOUS SUBMISSION CAUSED BY A SOFTWARE GLITCH IN THE TRANSMISSION PROCESS. THE INTERNAL NON-CONFORMANCE NUMBERS FOR THIS SOFTWARE ISSUE ARE (B)(4) AND CAPA-010215.
MODEL #: THE MODEL # IS UNKNOWN AS SERIAL NUMBER WAS NOT PROVIDED. CATALOG #: THE CATALOG # IS UNKNOWN AS SERIAL NUMBER WAS NOT PROVIDED. UNIQUE IDENTIFIER (UDI#): UNKNOWN, AS SERIAL NUMBER WAS NOT PROVIDED. EXPIRATION DATE: UNKNOWN, AS SERIAL NUMBER WAS NOT PROVIDED. THE DEVICE WAS NOT RETURNED FOR ANALYSIS. THE SERIAL NUMBER FOR THE DEVICE WAS NOT AVAILABLE; THEREFORE, NO FURTHER INVESTIGATION CAN BE PERFORMED. IF THERE IS ANY FURTHER RELEVANT INFORMATION RECEIVED, A SUPPLEMENTAL MEDWATCH WILL BE FILED. DEVICE MANUFACTURE DATE: UNKNOWN AS SERIAL NUMBER WAS NOT PROVIDED. (B)(4). CITATION: SE HYUN CHOI, HYO KYUNG LEE, CHANG HO YOON AND MEE KUM KIM (2019). VISUAL PERFORMANCE AFTER A UNILATERAL OR BILATERAL IMPLANTATION OF ENLARGED DEPTH-OF-FOCUS INTRAOCULAR LENS IN PATIENTS WITH CATARACT: A PROSPECTIVE CLINICAL TRIAL. JOURNAL OF OPHTHALMOLOGY 2019, ARTICLE ID 2163809, 8 PAGES. ALL PERTINENT INFORMATION AVAILABLE TO JOHNSON & JOHNSON SURGICAL VISION, INC. HAS BEEN SUBMITTED.
ARTICLE: VISUAL PERFORMANCE AFTER A UNILATERAL OR BILATERAL IMPLANTATION OF ENLARGED DEPTH-OF-FOCUS INTRAOCULAR LENS IN PATIENTS WITH CATARACT: A PROSPECTIVE CLINICAL TRIAL. AUTHORS: SE HYUN CHOI, HYO KYUNG LEE, CHANG HO YOON AND MEE KUM KIM. PUBLICATION: JOURNAL OF OPHTHALMOLOGY 2019, ARTICLE ID 2163809, 8 PAGES. THE PUBLICATION REPORTS TWO PATIENTS COMPLAINED OF GLARE SYMPTOMS POSTOPERATIVE AT 12 WEEKS. NO ADDITIONAL INFORMATION WAS PROVIDED TO JOHNSON & JOHNSON SURGICAL VISION. THIS REPORT IS FOR THE SECOND OF TWO PATIENTS. A SEPARATE MDR WILL BE SUBMITTED FOR THE OTHER REPORTED PATIENT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 773543 | TECNIS SYMFONY TORIC | MULTIFOCAL IOLS | POE | JOHNSON & JOHNSON SURGICAL VISION, INC. | UNKNOWN |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Other |