FDA Adverse Event Malfunction Summary report: N

CONNECTA PLUS3 10CM WHITE

MDR report key: 8975052 · Received September 9, 2019

Report

Report Number
9610847-2019-00556
Event Type
Malfunction
Date Received
September 9, 2019
Date of Event
August 22, 2019
Report Date
October 22, 2019
Manufacturer
BD INFUSION THERAPY SYSTEMS INC. S.A. DE C.V.
Product Code
FMG
PMA / PMN Number
N/A
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
FI
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

INVESTIGATION SUMMARY: A DEVICE HISTORY REVIEW WAS CONDUCTED FOR LOT NUMBER 9031772. OUR RECORDS SHOW THAT THIS IS THE ONLY INSTANCE OF THIS ISSUE OCCURRING IN THIS PRODUCTION BATCH. ACCORDING TO THE SAMPLING PLAN APPLIED FOR PRODUCT PERFORMANCE, THIS LOT WAS ACCEPTED AND RELEASED WITHOUT DEFECTS BEING NOTED DURING THE FINAL ASSEMBLY OR VISUAL INSPECTIONS. A SAMPLE COULD NOT BE OBTAINED FOR EVALUATION AND TESTING. WITHOUT THE ABILITY TO INVESTIGATE THE AFFECTED UNIT OUR QUALITY ENGINEERS WERE UNABLE TO DETERMINE THE ROOT CAUSE FOR THIS COMPLAINT.

Description of Event or Problem · 0

IT WAS REPORTED THAT AN UNSPECIFIED NUMBER OF CONNECTA PLUS3 10CM WHITE EXPERIENCED A STOPCOCK/CAP LOOSE CONNECTION/SEPARATED/DETACHED DURING USE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: CAP HAS FALLEN OFF WHILE GIVING IV FLUID TO PATIENT. IT HAS FALLEN OFF WHILE PATIENT IS IN THE BED AND BLOOD STAINED FLUID WAS FOUND IN PATIENT¿S BED. CONNECTA SIDE CAPS FALL OFF TOO OFTEN ALREADY WHEN OPENING THE PACKAGE OR SIDE CAP FALLS OFF WHEN RUNNING IV- FLUIDS.

Additional Manufacturer Narrative · 1

DATE OF EVENT: UNKNOWN. THE DATE RECEIVED BY MANUFACTURER HAS BEEN USED FOR THIS FIELD. A DEVICE EVALUATION IS ANTICIPATED, BUT HAS NOT YET BEGUN. UPON COMPLETION OF THE INVESTIGATION, A SUPPLEMENTAL REPORT WILL BE FILED.

Description of Event or Problem · 1

IT WAS REPORTED THAT AN UNSPECIFIED NUMBER OF CONNECTA PLUS3 10 CM WHITE EXPERIENCED A STOPCOCK/CAP LOOSE CONNECTION/SEPARATED/DETACHED DURING USE. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: CAP HAS FALLEN OFF WHILE GIVING IV FLUID TO PATIENT. IT HAS FALLEN OFF WHILE PATIENT IS IN THE BED AND BLOOD STAINED FLUID WAS FOUND IN PATIENT¿S BED. CONNECTA SIDE CAPS FALL OFF TOO OFTEN ALREADY WHEN OPENING THE PACKAGE OR SIDE CAP FALLS OFF WHEN RUNNING IV- FLUIDS.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
767531 CONNECTA PLUS3 10CM WHITE STOP COCK FMG BD INFUSION THERAPY SYSTEMS INC. S.A. DE C.V. 9031772

Patients

Seq Age Sex Outcome Treatment
1 Other