SUTURE, ABSORBABLE, SYNTHETIC
Report
- Report Number
- 2210968-2019-86606
- Event Type
- Injury
- Date Received
- September 5, 2019
- Report Date
- August 13, 2019
- Manufacturer
- ETHICON INC.
- Product Code
- GAM
- PMA / PMN Number
- K033746
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Occupation
- OTHER
Narratives
(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. ATTEMPTS ARE BEING MADE TO OBTAIN THE FOLLOWING INFORMATION. TO DATE NO RESPONSE HAS BEEN PROVIDED. IF FURTHER DETAILS ARE RECEIVED AT A LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. WERE THE CASES DISCUSSED IN THIS ARTICLE PREVIOUSLY REPORTED TO ETHICON? IF YES, PLEASE PROVIDE A COMPLAINT REFERENCE NUMBER. DOES THE SURGEON BELIEVE THAT ETHICON PRODUCT (VICRYL TAPE) INVOLVED CAUSED AND/OR CONTRIBUTED TO THE POST-OPERATIVE COMPLICATIONS DESCRIBED IN THE ARTICLE? DOES THE SURGEON BELIEVE THERE WAS ANY DEFICIENCY WITH THE ETHICON PRODUCT (VICRYL TAPE) INVOLVED? CITATION: BONE JOINT J 2017;99-B:344¿50; DOI:10.1302/0301-620X.99B3.37884. (B)(4).
IT WAS REPORTED VIA A JOURNAL ARTICLE"TITLE: TRACHELOPLASTY WITH A FLEXIBLE OSTEOCHONDRAL FLAP". AUTHORS: A. J. METCALFE; D. A. CLARK; M. A. KEMP; J. D. ELDRIDGE. CITATION: BONE JOINT J 2017;99-B:344¿50; DOI:10.1302/0301-620X.99B3.37884. THE BEREITER TRACHELOPLASTY HAS BEEN USED IN OUR UNIT FOR 12 YEARS TO MANAGE RECURRENT PATELLAR INSTABILITY IN PATIENTS WITH SEVERE TROCHLEA DYSPLASIA. THE AIM OF THIS STUDY WAS TO DOCUMENT THE OUTCOME OF A LARGE CONSECUTIVE COHORT OF PATIENTS WHO HAVE UNDERGONE THIS OPERATION. BETWEEN JUNE 2002 AND 01 AUGUST 2013, 214 TRACHELOPLASTIES WERE CARRIED OUT IN 185 PATIENTS (FEMALE=133, MALE=52; MEAN AGE=21.3 YEARS, AGE RANGE 14-38). TWO VICRYL TAPES (ETHICON) WERE PLACED IN THE CENTRE OF THE GROOVE AND TIED OVER A BONE BRIDGE LATERALLY TO SECURE FLAP. REPORTED COMPLICATIONS INCLUDED PARTIAL DETACHMENT OF THE CARTILAGE FLAP (N=1) IN WHICH THE LOOSE FRAGMENT WAS REMOVED BY ARTHROSCOPY AND MICROFRACTURE IF THE EXPOSED BONE WAS PERFORMED; PERSISTENT POST-OPERATIVE COMPLEX REGIONAL PAIN SYNDROME (N=1); PERSISTENT AND UNEXPLAINED FOOT DROP (N=1) DESPITE NORMAL NERVE CONDUCTION STUDIES AND NORMAL MRI SCANS OF THE KNEE AND SPINE; FRANK DISLOCATION (N=2) IN WHICH THE PATIENT HAD MEDIAL PATELLOFEMORAL LIGAMENT RECONSTRUCTION (MPFL); GENERAL PERCEIVED INSTABILITY (N=5) WHICH THE PATIENTS HAD RE-OPERATIONS; FEELING OF SUBLUXATION AND VISIBLE MAL-TRACKING INTO THE GROOVE IN EXTENSION (N=2) WHICH THE PATIENTS HAD RE-OPERATIONS; FURTHER DISLOCATIONS (N=8%) WHICH SIX PATIENTS STATED THAT THEIR INSTABILITY SYMPTOMS HAD BEEN IMPROVED BY THE OPERATION. IN CONCLUSION, PATIENTS WITH RECURRENT PATELLAR INSTABILITY AND SEVERE TROCHLEAR DYSPLASIA CAN BE SUCCESSFULLY TREATED WITH A BEREITER TRACHELOPLASTY. HIGH LEVELS OF SATISFACTION AND GOOD PATIENT REPORTED OUTCOMES CAN BE ACHIEVED WITH LOW RATES OF POST-OPERATIVE OSTEOARTHRITIS IN THE MEDIUM TERM.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 760304 | SUTURE, ABSORBABLE, SYNTHETIC | GAM | ETHICON INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |