VICRYL TAPE UNKNOWN
Report
- Report Number
- 2210968-2019-86570
- Event Type
- Injury
- Date Received
- September 5, 2019
- Report Date
- August 13, 2019
- Manufacturer
- ETHICON INC.
- Product Code
- GAM
- PMA / PMN Number
- K033746
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Occupation
- OTHER
Narratives
(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. CITATION: KNEE SURG SPORTS TRAUMATOL ARTHROSC (2011) 19:1655¿1661; DOI 10.1007/S00167-011-1410-7. (B)(4).
IT WAS REPORTED VIA A JOURNAL ARTICLE "TITLE : CLASSIFICATION OF TROCHLEAR DYSPLASIA AS PREDICTOR OF CLINICAL OUTCOME AFTER TROCHLEOPLASTY"AUTHOR : SANDRO F. FUCENTESE ¿ PATRICK O. ZINGG ¿JU¨RGEN SCHMITT ¿ CHRISTIAN W. A. PFIRRMANN ¿DOMINIK C. MEYER ¿ PETER P. KOCH CITATION: KNEE SURG SPORTS TRAUMATOL ARTHROSC (2011) 19:1655¿1661; DOI 10.1007/S00167-011-1410-7. SULCUS-DEEPENING TROCHLEOPLASTY RESTORES THE TROCHLEAR GROOVE IN PATIENTS WITH PATELLOFEMORAL INSTABILITY AND UNDERLYING TROCHLEAR DYSPLASIA. THE AIM OF THIS STUDY WAS TO IDENTIFY INFLUENCING FACTORS FOR THE CLINICAL OUTCOME FOLLOWING TROCHLEOPLASTY. BETWEEN 1999 AND 2006, 44 KNEES IN 38 PATIENTS (MALE=10, FEMALE=28; MEAN AGE=18 YEARS, AGE RANGE=14 ¿ 40 YEARS) UNDERWENT TROCHLEOPLASTY FOR THE TREATMENT FOR TROCHLEAR DYSPLASIA. THE GREATEST DEPTH THE GROOVE REACHES IS ABOUT 6 MM, WITH A SMOOTH GRADUATION AT EITHER END. THE OSTEOCHONDRAL FLAKE IS PRESSED INTO THE NEWLY FORMED GROOVE AND FIXED WITH TWO TRANSOSSEUS VICRYL NO. 5 SUTURES (VICRYL-TAPE, ETHICON) IN THE DEEPEST PART OF THE NEW TROCHLEA. THE SYNOVIUM IS REATTACHED TO THE CARTILAGINOUS EDGES WITH A CONTINUOUS ABSORBABLE SUTURE. THE TENDON OF THE VASTUS MEDIALIS OBLIQUUS MUSCLE (VMO) IS TIGHTENED MEDIALLY AND ATTACHED TO THE PATELLA WITH ONE CROSS-STITCH, AND THE JOINT IS CLOSED WITH A CONTINUOUS ABSORBABLE SUTURE WITHOUT CLOSING THE LATERAL RETINACULUM, LEAVING AN INDIRECT LATERAL RELEASE. REPORTED COMPLICATIONS INCLUDED INCREASED ONGOING PAIN (N=3) WHICH THE PATIENTS UNDERWENT FURTHER ARTHROSCOPIC DEBRIDEMENT WITH THE REMOVAL OF LOOSE BODIES IN ONE KNEE; NEW RECURRENT ATRAUMATIC DISLOCATION (N=1); PERSISTENT PAIN (N=2); AND COMPLEX REGIONAL PAIN SYNDROME (N=1). IN CONCLUSION, TROCHLEOPLASTY IS A USEFUL AND RELIABLE SURGICAL TECHNIQUE TO IMPROVE PATELLOFEMORAL INSTABILITY IN PATIENTS WITH A DYSPLASTIC TROCHLEA. WHILE IMPROVED STABILITY IS PREDICTABLE, PAIN IS LESS PREDICTABLE AND MAY EVEN INCREASE FOLLOWING SURGERY.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 759860 | VICRYL TAPE UNKNOWN | SUTURE, ABSORBABLE, SYNTHETIC | GAM | ETHICON INC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |