FDA Adverse Event Injury Summary report: N

UNKNOWN HIP FEMORAL HEAD

MDR report key: 8952811 · Received August 30, 2019

Report

Report Number
1818910-2019-102804
Event Type
Injury
Date Received
August 30, 2019
Date of Event
November 8, 2012
Report Date
August 13, 2019
Manufacturer
DEPUY ORTHOPAEDICS, INC. 1818910
Product Code
KWY
Removal / Correction Number
Z-1749/1816-2011
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
FI
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

PRODUCT COMPLAINT # (B)(4). INVESTIGATION SUMMARY: NO DEVICE ASSOCIATED WITH THIS REPORT WAS RECEIVED FOR EXAMINATION. A WORLDWIDE LOT SPECIFIC COMPLAINT DATABASE SEARCH, OR DEVICE HISTORY RECORD (DHR) REVIEW WAS NOT POSSIBLE BECAUSE THE REQUIRED LOT CODE(S) WAS NOT PROVIDED. BASED ON PREVIOUS INVESTIGATIONS THIS COMPLICATION OF JOINT REPLACEMENT IS UNLIKELY TO HAVE BEEN THE RESULT OF A DEVICE FAILING TO MEET REQUIRED SPECIFICATIONS. THE INFORMATION RECEIVED WILL BE RETAINED FOR POTENTIAL SERIES INVESTIGATIONS IF TRIGGERED BY TREND ANALYSIS, POST MARKET SURVEILLANCE, OR OTHER EVENTS WITHIN THE QUALITY SYSTEM. CORRECTIVE ACTION WAS NOT INDICATED. (B)(4). NO 510(K) NUMBER PROVIDED BECAUSE THIS IMPLANT IS SOLD INTERNATIONALLY WITH DIFFERENT INDICATIONS FOR USE; IT IS CURRENTLY SOLD IN THE US UNDER A DIFFERENT PART NUMBER. THE CORRECTION/REMOVAL REPORTING NUMBER LISTED APPLIES TO THE CORRESPONDING PRODUCT CODE SOLD DOMESTICALLY. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Description of Event or Problem · 1

"LITERATURE ARTICLE ENTITLED ""RESULTS OF METAL-ON-METAL HIP RESURFACING IN PATIENTS 40 YEARS OLD AND YOUNGER ALEKSI REITO, ANTTI ESKELINEN, TIMO PUOLAKKA, JORMA PAJAMA¨KI PUBLISHED ONLINE 08 NOVEMBER 2012 BYARCH ORTHOP TRAUMA SURG (2013) 133:267¿273 DOI 10.1007/S00402-012-1640-2 WAS REVIEWED FOR MDR REPORTABILITY. ARTICLE PURPOSE: ""THE PRIMARY AIM OF OUR STUDY WAS TO DETERMINE THE SURVIVORSHIP OF MMHR IN PATIENTS AGED 40 YEARS OR LESS. OUR SECOND AIM WAS TO ANALYSE ACTIVITY AND QUALITY OF LIFE AFTER MMHR IN THIS PATIENT POPULATION, LIKEWISE THE PREVALENCE OF COMORBID SITUATIONS AND THEIR INFLUENCE ON CLINICAL OUTCOME."" THE ARTICLE INCLUDES IMPLANTS: ""BETWEEN MAY 2001 AND MAY 2008 A TOTAL OF 1,092 HIP RESURFACING ARTHROPLASTIES WERE PERFORMED ON 931 PATIENTS IN OUR INSTITUTION. OF THESE OPERATIONS, 75 WERE PERFORMED ON 64 PATIENTS AGED UNDER 40 AT THE TIME OF THE PRIMARY OPERATION. THE INDICATIONS FOR ARTHROPLASTY WERE SEVERE PAIN AND/OR CONSIDERABLE DIFFICULTY WITH WALKING AND PERFORMING DAILY ACTIVITIES. FOUR HIPS IN FOUR PATIENTS HAD BEEN REVISED BEFORE THE DATA COLLECTION AND NO PATIENT HAD DIED. THE REMAINING 60 PATIENTS WERE ASKED TO PARTICIPATE IN THIS FOLLOW-UP STUDY. OF THE PATIENTS, 51 (85 %, 60 HIPS) AGREED TO DO SO BY RETURNING THE SIGNED INFORMED CONSENT FORM. NINE PATIENTS DECLINED, GIVING LACK OF INTEREST AS THEIR REASON FOR NOT PARTICIPATING. NONE OF THE PATIENTS WHO REFUSED HAD UNDERGONE REVISION. THE MEAN FOLLOWUP TIME WAS 6.0 YEARS (RANGE 3.0¿7.6)...TO DATE SIX HIPS (SIX PATIENTS) WITH ASR IMPLANTS AND TWO HIPS WITH BHR IMPLANTS HAVE BEEN REVISED AND SEVEN OF THESE REOPERATIONS WERE PERFORMED DUE TO AN ADVERSE REACTION TO METAL DEBRIS (ARMED) IN ALL SEVEN REVISED PATIENTS, A DIAGNOSIS OF ARMED WAS CONFIRMED IN REVISION. THE PSEUDOTUMOR WAS RESECTED AND BOTH PROSTHETIC COMPONENTS WERE CHANGED TO A CEMENTLESS THR WITH CERAMIC-ON-CERAMIC ARTICULATION ONE MALE PATIENT (ONE HIP) WITH 51/58 MM ASR COMPONENTS WAS OPERATED ON AGAIN DUE TO SEVERE HETEROTOPIC OSSIFICATION. TABLE 3 PROVIDES DETAILED INFORMATION FOR EACH CASE ASSOCIATED WITH DEPUY ASR ENTAILING 5 OF THE 7 REVISION CASES." CASE 2 (B)(6) YO FEMALE DIAGNOSED WITH DDH WITH ASR IMPLANT, ABDUCTION ANGLE 56 DEGREES WITH 4.4 YEARS TIME TO REVISION SUFFERING FROM MODERATE PAIN, CO 217 MCG/L AND CR 94 MCG/L; OPERATIVE FINDINGS: EXTENSIVE METALLOSIS, OSTEOLYSIS IN THE ACETABULAR SIDE.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
746547 UNKNOWN HIP FEMORAL HEAD HIP FEMORAL HEAD KWY DEPUY ORTHOPAEDICS, INC. 1818910 NA

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention