FDA Adverse Event Malfunction Summary report: N

BD VACUTAINER® SST¿ BLOOD COLLECTION TUBE

MDR report key: 8916038 · Received August 21, 2019

Report

Report Number
1024879-2019-01490
Event Type
Malfunction
Date Received
August 21, 2019
Date of Event
August 5, 2019
Report Date
October 8, 2019
Manufacturer
BECTON, DICKINSON & CO., (BD)
Product Code
JKA
UDI-DI
50382903679862
PMA / PMN Number
BK050036
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
NY, US
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 0

INVESTIGATION SUMMARY: BD RECEIVED SAMPLES FROM THE CUSTOMER FACILITY FOR INVESTIGATION. THE SAMPLES WERE TESTED/EVALUATED AND THE CUSTOMER'S INDICATED FAILURE MODE FOR STOPPER POP OFF WITH THE INCIDENT LOT WAS NOT OBSERVED AS ALL PRODUCT SPECIFICATIONS WERE MET. A REVIEW OF THE DEVICE HISTORY RECORD WAS COMPLETED FOR THE INCIDENT LOT AND, BASED ON THIS REVIEW, ALL PRODUCT SPECIFICATIONS AND REQUIREMENTS FOR LOT RELEASE WERE MET; THERE WERE NO RELATED QUALITY NON-CONFORMANCES DURING MANUFACTURING OF THE PRODUCT.

Description of Event or Problem · 0

IT HAS BEEN REPORTED THAT ONE BD VACUTAINER® SST¿ BLOOD COLLECTION TUBE HAS BEEN FOUND WITH THE STOPPER POPPING OUT DURING USE. THE FOLLOWING HAS BEEN PROVIDED BY THE INITIAL REPORTER: -IT WAS REPORTED STOPPER POPPED OFF. EMAIL VERBIAGE RECEIVED, - "SST (GOLD) TUBE FOR CHEMISTRY TESTING- THE TOP COME OFF DURING DRAWING SAMPLE AND THEY HAVE TO TAKE ANOTHER TUBE TO COMPLETE SAMPLE DRAWING. THIS IS ALSO AN ONGOING ISSUE. SST (GOLD) ¿ LOT# 9042893, EXP: 1/31/2020"

Additional Manufacturer Narrative · 1

DATE OF EVENT: UNKNOWN. THE DATE RECEIVED BY MANUFACTURER HAS BEEN USED FOR THIS FIELD. A DEVICE EVALUATION AND/OR DEVICE HISTORY REVIEW IS ANTICIPATED, BUT IS NOT COMPLETE. UPON COMPLETION, A SUPPLEMENTAL REPORT WILL BE FILED.

Description of Event or Problem · 1

IT HAS BEEN REPORTED THAT ONE BD VACUTAINER® SST¿ BLOOD COLLECTION TUBE HAS BEEN FOUND WITH THE STOPPER POPPING OUT DURING USE. THE FOLLOWING HAS BEEN PROVIDED BY THE INITIAL REPORTER: IT WAS REPORTED STOPPER POPPED OFF. EMAIL VERBIAGE RECEIVED, - "SST (GOLD) TUBE FOR CHEMISTRY TESTING- THE TOP COME OFF DURING DRAWING SAMPLE AND THEY HAVE TO TAKE ANOTHER TUBE TO COMPLETE SAMPLE DRAWING. THIS IS ALSO AN ONGOING ISSUE. SST (GOLD) ¿ LOT# 9042893, EXP: 1/31/2020."

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
712670 BD VACUTAINER® SST¿ BLOOD COLLECTION TUBE BLOOD SPECIMEN COLLECTION DEVICE JKA BECTON, DICKINSON & CO., (BD) 9042893 50382903679862

Patients

Seq Age Sex Outcome Treatment
1 Other