ENDOPATH*MULTIFEED STAPLER
Report
- Report Number
- 3005075853-2019-21315
- Event Type
- Injury
- Date Received
- August 16, 2019
- Report Date
- August 1, 2019
- Manufacturer
- ETHICON ENDO-SURGERY, LLC.
- Product Code
- GCJ
- PMA / PMN Number
- K913469
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Occupation
- PHYSICIAN
Narratives
(B)(4). DATE OF EVENT: UNKNOWN. BATCH # UNKNOWN. AS THE DEVICE WAS NOT RETURNED, AN ANALYSIS INVESTIGATION COULD NOT BE PERFORMED. A CONCLUSION COULD NOT BE REACHED AS TO WHAT MAY HAVE CAUSED OR CONTRIBUTED TO THE EVENT. THE LOT/BATCH WAS NOT PROVIDED; THEREFORE, THE MANUFACTURING RECORDS COULD NOT BE REVIEWED. (B)(4).
IT WAS REPORTED VIA JOURNAL ARTICLE: TITLE: RANDOMIZED CLINICAL TRIAL COMPARING 5-YEAR RECURRENCE RATE AFTER LAPAROSCOPIC VERSUS SHOULDICE REPAIR OF PRIMARY INGUINAL HERNIA AUTHOR(S): D. ARVIDSSON; F. H. BERNDSEN; L. G. LARSSON; C.-E. LEIJONMARCK; G. RIMBACK; C. RUDBERG; S. SMEDBERG; L. SPANGEN; A. MONTGOMERY. CITATION: BRITISH JOURNAL OF SURGERY 2005; 92: 1085¿1091; DOI: 10.1002/BJS.5137. THE AIM OF THIS STUDY WAS TO COMPARE THE 5-YEAR RECURRENCE RATES AFTER SHOULDICE AND LAPAROSCOPIC TRANSABDOMINAL PREPERITONEAL PATCH (TAPP) REPAIR FOR PRIMARY INGUINAL HERNIA. BETWEEN FEBRUARY 1993 AND MARCH 1996, 1183 PATIENTS WITH PRIMARY INGUINAL HERNIAS WERE RANDOMIZED INTO TWO GROUPS IN WHICH 920 PATIENTS COMPLETED THE 5 -YEAR FOLLOW UP: IN TAPP GROUP (N=454; MEAN AGE 51.2 YEARS) AND IN SHOULDICE GROUP (N=466; MEAN AGE=52.2). IN THE TAPP OPERATION, THE PERITONEUM WAS OPENED ABOVE THE INTERNAL RING AND THE PREPERITONEAL SPACE WAS ENTERED. AFTER DISSECTION OF THE HERNIA SAC AND PREPARATION OF COOPER¿S LIGAMENT AND THE TRIANGLE OF DOOM, A 7 X 12 CM PROLENE MESH (ETHICON) WAS INSERTED AND STAPLED IN PLACE USING AN ENDOSCOPIC STAPLER (EMS MULTIFEED STAPLEGUN, ETHICON). CARE WAS TAKEN NOT TO USE STAPLES BELOW THE ILIOPUPIC TRACT. THE PERITONEUM WAS STAPLED IN PLACE TO COVER THE MESH COMPLETELY. IN TAPP REPAIR, RECURRENCE (N=30) WAS OBSERVED OF WHICH, THE PATIENTS WERE EITHER REOPERATED OR HAD A POSITIVE HERNIOGRAM. IN THIS RANDOMIZED MULTICENTRE TRIAL THERE WAS NO DIFFERENCE IN THE 5-YEAR RECURRENCE RATE AFTER LAPAROSCOPIC TAPP AND SHOULDICE REPAIRS.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 696421 | ENDOPATH*MULTIFEED STAPLER | LAPAROSCOPE, GENERAL AND PLASTIC SURGERY | GCJ | ETHICON ENDO-SURGERY, LLC. |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |