FDA Adverse Event Malfunction Summary report: N

MAGIC3 GO¿ INTERMITTENT URINARY CATHETER

MDR report key: 8897769 · Received August 15, 2019

Report

Report Number
1018233-2019-04762
Event Type
Malfunction
Date Received
August 15, 2019
Report Date
August 15, 2019
Manufacturer
C.R. BARD, INC. (COVINGTON) -1018233
Product Code
EZD
UDI-DI
00801741137037
PMA / PMN Number
K172247
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
FL, US
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 1

THE DEVICE WAS NOT RETURNED FOR EVALUATION. A POTENTIAL ROOT CAUSE OF THIS FAILURE MODE COULD BE "OPERATOR ERROR - VISCOMETER OOC - VISCOMETER FAILURE - MECHANICAL FAILURE". THE LOT NUMBER IS UNKNOWN; THEREFORE, THE DEVICE HISTORY RECORD COULD NOT BE REVIEWED. THE INSTRUCTIONS FOR USE WERE FOUND ADEQUATE AND STATE THE FOLLOWING: "REVIEW THE SELF-CATHETERIZATION PROCEDURE WITH A HEALTHCARE PROFESSIONAL. ALWAYS WASH HANDS PRIOR TO USE. OPEN THE CATHETER PACKAGE BY PEELING THE TAB UPWARDS WITH THE AID OF THE FINGER HOLE. IF DESIRED, USE THE ADHESIVE LABEL(S) TO HANG THE PACKAGE ON A NEARBY DRY VERTICAL SURFACE WHILE PREPARING TO CATHETERIZE. CLEAN THE OPENING TO THE URETHRA ¿ AND THE SURROUNDING AREA. WIPE FROM FRONT TO BACK TO AVOID FECAL CONTAMINATION. WASH YOUR HANDS AGAIN. HOLD THE INSERTION SLEEVE WITH YOUR DOMINANT HAND AND SQUEEZE IT TO GRIP THE CATHETER SHAFT AS YOU REMOVE THE CATHETER FROM THE PACK. NEXT, HOLD THE CATHETER FUNNEL ABOVE THE INSERTION SLEEVE WITH YOUR OTHER HAND AND SLIDE THE INSERTION SLEEVE DOWN THE SHAFT, STOPPING AT ABOUT 6¿ FROM THE TIP. RELEASE THE FUNNEL. USING THE INSERTION SLEEVE TO HOLD THE CATHETER FIRMLY, GENTLY PASS THE TIP OF THE CATHETER INTO YOUR URETHRA UNTIL THE INSERTION SLEEVE NEARS THE MEATUS. REPEAT UNTIL URINE STARTS TO FLOW. KEEP THE CATHETER STEADY UNTIL URINE STOPS FLOWING. WHEN URINE STOPS FLOWING, SLOWLY WITHDRAW THE CATHETER, STOPPING IF FLOW STARTS AGAIN, UNTIL THE LAST FEW DROPS HAVE DRAINED. CHECK THE COLOR, ODOR AND CLARITY OF THE URINE. ANY CHANGES MAY NEED TO BE REPORTED TO A HEALTH CARE PROFESSIONAL. DISPOSAL PLACE THE CATHETER BACK INTO THE PACKAGE AND DISPOSE IN ACCORDANCE WITH ACCEPTED MEDICAL PRACTICE AND APPLICABLE LOCAL, STATE AND FEDERAL LAWS AND REGULATIONS. DO NOT FLUSH DOWN THE TOILET. WASH HANDS."

Description of Event or Problem · 1

IT WAS REPORTED THAT A FEW OF THE MAGIC 3 GO COUDE CATHETERS WERE DRY.