FDA Adverse Event Injury Summary report: N

UNK - PLATES: RECONSTRUCTION

MDR report key: 8888399 · Received August 13, 2019

Report

Report Number
2939274-2019-59782
Event Type
Injury
Date Received
August 13, 2019
Report Date
July 22, 2019
Manufacturer
WRIGHTS LANE SYNTHES USA PRODUCTS LLC
Product Code
HRS
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
WA, US
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 1

A TOTAL OF 23 PATIENTS (18 MALES AND 5 FEMALES) WITH A MEAN AGE OF 35.3 YEARS (RANGE 17-63) WERE INCLUDED IN THIS STUDY. THIS REPORT IS FOR AN UNKNOWN 3.5MM RECONSTRUCTION PLATE/UNKNOWN LOT. PART AND LOT NUMBER ARE UNKNOWN; UDI NUMBER IS UNKNOWN. COMPLAINANT PART IS NOT EXPECTED TO BE RETURNED FOR MANUFACTURER REVIEW/INVESTIGATION. WITHOUT A LOT NUMBER THE DEVICE HISTORY RECORDS REVIEW COULD NOT BE COMPLETED. PRODUCT WAS NOT RETURNED. BASED ON THE INFORMATION AVAILABLE, IT HAS BEEN DETERMINED THAT NO CORRECTIVE AND/OR PREVENTATIVE ACTION IS PROPOSED. THIS COMPLAINT WILL BE ACCOUNTED FOR AND MONITORED VIA POST MARKET SURVEILLANCE ACTIVITIES. IF ADDITIONAL INFORMATION IS MADE AVAILABLE, THE INVESTIGATION WILL BE UPDATED AS APPLICABLE. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE. (B)(4).

Description of Event or Problem · 1

THIS REPORT IS BEING FILED AFTER THE REVIEW OF THE FOLLOWING JOURNAL ARTICLE: ROUTT, M.L. ET. AL. (1996), INTERNAL FIXATION IN PELVIC FRACTURES AND PRIMARY REPAIRS OF ASSOCIATED GENITOURINARY DISRUPTIONS: A TEAM APPROACH, THE JOURNAL OF TRAUMA: INJURY, INFECTION, AND CRITICAL CARE, VOL. 40(5), PAGES 784-790 (USA). 10.1097/00005373-199605000-00018. THIS STUDY DESCRIBES A TREATMENT PROTOCOL AND REPORTS THE EARLY RESULTS OF 23 PATIENTS WITH UNSTABLE PELVIC FRACTURES AND ASSOCIATED BLADDER OR URETHRAL DISRUPTIONS, OR BOTH, TREATED SURGICALLY WITH OPEN REDUCTION AND INTERNAL FIXATION OF THE ANTERIOR PELVIC RING INJURIES AT THE SAME ANESTHETIC AND USING THE SAME SURGICAL EXPOSURE AS THE URETHRAL REALIGNMENTS OR BLADDER REPAIRS, OR BOTH. A TOTAL OF 23 PATIENTS (18 MALES AND 5 FEMALES) WITH A MEAN AGE OF 35.3 YEARS (RANGE 17-63) WERE INCLUDED IN THIS STUDY. 17 PATIENTS HAD ANTERIOR PELVIC STABILIZATIONS, AFTER OPEN REDUCTIONS, USING SINGLE 3.5-MM RECONSTRUCTION PLATES (SYNTHES, INC., PAOLI, PA.) OF VARIABLE LENGTHS DEPENDENT UPON THE INJURY PATTERNS. 5 PATIENTS HAD 2-HOLE 4.5-MM NARROW DYNAMIC COMPRESSION PLATES (SYNTHES, INC., PAOLI, PA) USED FOR SYMPHYSEAL FIXATION. FOLLOW-UP EXAMINATIONS WERE AVAILABLE FOR ALL THE PATIENTS AND RANGED FROM 3 TO 36 MONTHS WITH A MEAN OF 15.5 MONTHS. THE FOLLOWING COMPLICATIONS WERE REPORTED AS FOLLOWS: 3 OF 4 MALE PATIENTS WITH URETHRAL DISRUPTIONS HAD URETHRAL STRICTURE AFTER THEIR PRIMARY URETHRAL REALIGNMENTS. THESE PATIENTS WERE TREATED WITH ENDOSCOPIC URETHROMIES. 2 OF THESE 4 PATIENTS REQUIRED SECOND URETHROTOMIES FOR RECURRENT STRICTURES. ADDITIONAL DEVICES FOR THIS ARTICLE ARE CAPTURED ON RELATED COMPLAINTS (B)(4). THIS REPORT IS FOR AN UNKNOWN 3.5MM RECONSTRUCTION PLATE. THIS IS REPORT 1 OF 10 FOR (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
681930 UNK - PLATES: RECONSTRUCTION PLATE, FIXATION, BONE HRS WRIGHTS LANE SYNTHES USA PRODUCTS LLC

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention