PROXIMATE*HCS HEMORR CIR STAPL
Report
- Report Number
- 3005075853-2019-20903
- Event Type
- Injury
- Date Received
- July 30, 2019
- Date of Event
- January 1, 2005
- Report Date
- July 11, 2019
- Manufacturer
- ETHICON ENDO-SURGERY, LLC.
- Product Code
- GDW
- UDI-DI
- 10705036012993
- PMA / PMN Number
- K030925
- Adverse Event
- Yes
- Report Source
- Manufacturer report
- Reporter Occupation
- OTHER
Narratives
(B)(4). DATE OF EVENT: PUBLICATION YEAR OF 2005. BATCH # UNK. THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE MANUFACTURING RECORDS CANNOT BE REVIEWED AS THE LOT/BATCH NUMBER HAS NOT BEEN PROVIDED. (B)(4).
TITLE: PROSPECTIVE RANDOMISED CLINICAL TRIAL OF SINGLE VERSUS DOUBLE PURSE-STRING STAPLED MUCOSECTOMY IN THE TREATMENT OF PROLAPSED HAEMORRHOIDS. AUTHORS: FRANCISCO PÉREZ-VICENTE, ANTONIO ARROYO, PILAR SERRANO, FERNANDO CANDELA, ANA SANCHEZ AND RAFAEL CALPENA. CITATION: INT J COLORECTAL DIS (2006) 21: 38¿43; DOI 10.1007/S00384-004-0720-3; PUBLISHED ONLINE: 21 APRIL 2005. THIS PROSPECTIVE RANDOMIZED CLINICAL TRIAL AIMED TO COMPARE THE OUTCOMES AFTER SINGLE PURSE-STRING CSM VERSUS DOUBLE PURSE-STRING CSM. BETWEEN MAY 2000 AND JUNE 2002, ONE HUNDRED CONSECUTIVE PATIENTS (MALE N=63, FEMALE N=37, MEAN AGE 50.70 YEARS) WERE RANDOMIZED TO SINGLE PURSE-STRING CSM (GROUP 1, N=50, MALE N=34, FEMALE N=16, WITH MEAN AGE 49.50 YEARS) VERSUS DOUBLE PURSE-STRING CSM (GROUP 2, N=50, MALE N=29, FEMALE N=21, WITH MEAN AGE 51.92 YEARS. THE OPERATION WAS CARRIED OUT ACCORDING TO THE TECHNIQUE INITIALLY DESCRIBED BY LONGO UTILIZING A 33-MM CIRCULAR STAPLING DEVICE (PPH 33-01, ETHICON ENDOSURGERY). COMPLICATIONS IN THE SINGLE PURSE GROUP INCLUDED ANASTOMOTIC BLEEDING REQUIRING TRANSFIXIVE SUTURE (N=14), STAPLE SUTURE DEFECT (N=2), PAIN ON DEFECATION (N=14), FREQUENT BLEEDING POSTOPERATIVE (N=7), DAILY BLEEDING POSTOPERATIVE (N=2) IN WHICH ONE PATIENT WAS TAKEN BACK TO THE OPERATING THEATRE WITHIN THE FIRST 12 POSTOPERATIVE HOURS; INCONTINENCE (N=7) WHICH SPONTANEOUSLY REVERSED WITH NO TREATMENT, PERSISTENT PAIN (N=3) IN WHICH ONE PATIENT HAD REMOVAL OF SEVERAL STAPLES THAT WERE TOO CLOSE TO THE DENTATE LINE AND RESIDUAL PROLAPSE/RECURRENCE (N=2) IN WHICH ONE PATIENT UNDERWENT ANOTHER CSM AND THE OTHER PATIENT UNDERWENT A MILLIGAN ¿ MORGAN PROCEDURE. IN THE DOUBLE PURSE GROUP, COMPLICATIONS INCLUDED ANASTOMOTIC BLEEDING REQUIRING TRANSFIXIVE SUTURE (N=23), STAPLE SUTURE DEFECT (N=1), PAIN ON DEFECATION (N=9), FREQUENT BLEEDING POSTOPERATIVE (N=7) AND INCONTINENCE (N=5) WHICH SPONTANEOUSLY REVERSED WITH NO TREATMENT. IN CONCLUSION, DOUBLE PURSE-STRING CSM RESECTS A GREATER DOUGHNUT AND INCREASES THE DISTANCE OF THE STAPLE SUTURE FROM THE DENTATE LINE IN COMPARISON TO SINGLE PURSE-STRING CSM, IMPROVING RESULTS IN TERMS OF EARLY POSTOPERATIVE PAIN. LARGER SERIES SHOULD BE NECESSARY TO ASSERT WHETHER RECURRENCE IS LOWER.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 634762 | PROXIMATE*HCS HEMORR CIR STAPL | STAPLE, IMPLANTABLE | GDW | ETHICON ENDO-SURGERY, LLC. | 10705036012993 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Required Intervention |