DRIVE SHAFT-MINIMUM 520MM LENGTH-FOR USE WITH RIA
Report
- Report Number
- 8030965-2019-66667
- Event Type
- Malfunction
- Date Received
- July 30, 2019
- Report Date
- July 2, 2019
- Manufacturer
- OBERDORF SYNTHES PRODUKTIONS GMBH
- Product Code
- HTO
- UDI-DI
- 07611819739208
- PMA / PMN Number
- K042899
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- GM
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
DEPUY SYNTHES IS SUBMITTING THIS REPORT PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH DEPUY SYNTHES HAS NOT BEEN ABLE TO INVESTIGATE OR VERIFY PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY FDA, DEPUY SYNTHES OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE DEVICE, DEPUY SYNTHES, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. H3, H4, H6: A DEVICE HISTORY RECORD (DHR) REVIEW WAS CONDUCTED: PART # 314.743, SYNTHES LOT # H479823, SUPPLIER LOT # H479823, RELEASE TO WAREHOUSE DATE: 23 OCT 2018, SUPPLIER: (B)(4). THE RAW MATERIAL WAS CONFIRMED TO BE CORRECT PER THE SPECIFICATION WITH NO (RELEVANT) NON-CONFORMANCE NOTED. NO NCR'S WERE GENERATED DURING PRODUCTION. REVIEW OF THE DEVICE HISTORY RECORD(S) SHOWED THAT THERE WERE NO ISSUES DURING THE MANUFACTURE OF THIS PRODUCT, AND ANY SUB-COMPONENTS, WHICH WOULD CONTRIBUTE TO THIS COMPLAINT CONDITION.,REVIEW OF THE DEVICE HISTORY RECORD(S) SHOWED THAT THERE WERE NO ISSUES DURING THE MANUFACTURE OF THIS PRODUCT, AND ANY SUB-COMPONENTS, WHICH WOULD CONTRIBUTE TO THIS COMPLAINT CONDITION. H6: PICTURE REVIEW: THE RECEIVED PICTURE CONFIRM THE ISSUE OF THE THE BROKEN DISTAL TIP AS PER EVENT DESCRIPTION; THE COMPLAINT THEREFORE HAS BEEN DETERMINED TO BE CONFIRMED. H3, H6: A PRODUCT INVESTIGATION WAS CONDUCTED. VISUAL INSPECTION: VISUAL INSPECTION PERFORMED AT CUSTOMER QUALITY OBSERVED THAT THE DISTAL TIP OF THE RETURNED SHAFT WAS BROKEN OFF. THE BROKEN PIECES WERE ALSO RECEIVED FOR INVESTIGATION. NO FURTHER ISSUES WERE NOTED. A DEVICE FAILURE WAS IDENTIFIED DIMENSIONAL INSPECTION: SHAFT PROXIMAL TO BREAKAGE WAS MEASURED AND IS WITHIN SPECIFICATIONS PER RELEVANT DRAWING. INVESTIGATION CONCLUSION: A DEFINITIVE ROOT CAUSE FOR THE DEVICE BREAKAGE COULD NOT BE DETERMINE IT IS POSSIBLE THAT THE DEVICE ENCOUNTERED UNINTENDED FORCES (DURING USAGE) THAT LED TO OBSERVED CONDITION. THE OVERALL COMPLAINT CONDITION IS CONFIRMED. DURING THE INVESTIGATION, NO PRODUCT DESIGN OR MANUFACTURING ISSUES WERE OBSERVED THAT MAY HAVE CONTRIBUTED TO THE COMPLAINT CONDITION. BASED ON THE INVESTIGATION FINDINGS, IT HAS BEEN DETERMINED THAT NO CORRECTIVE AND/OR PREVENTATIVE ACTION IS PROPOSED. ADDITIONAL MONITORING FOR ANY POTENTIAL SAFETY SIGNALS WILL BE CONDUCTED THROUGH COMPLAINT TRENDING AND OTHER POST MARKET SAFETY SURVEILLANCE ACTIVITIES. BASED ON THE INVESTIGATION FINDINGS, IT HAS BEEN DETERMINED THAT NO CORRECTIVE AND/OR PREVENTATIVE ACTION IS PROPOSED. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.
ADDITIONAL PROCODES: NBH, HRX. COMPLAINANT PART IS EXPECTED TO BE RETURNED FOR MANUFACTURER REVIEW/INVESTIGATION, BUT HAS YET TO BE RECEIVED. REPORTER IS A SYNTHES EMPLOYEE. THE INVESTIGATION COULD NOT BE COMPLETED; NO CONCLUSION COULD BE DRAWN, AS NO PRODUCT WAS RECEIVED. BASED ON THE INFORMATION AVAILABLE, IT HAS BEEN DETERMINED THAT NO CORRECTIVE AND/OR PREVENTATIVE ACTION IS PROPOSED. THIS COMPLAINT WILL BE ACCOUNTED FOR AND MONITORED VIA POST MARKET SURVEILLANCE ACTIVITIES. IF ADDITIONAL INFORMATION IS MADE AVAILABLE, THE INVESTIGATION WILL BE UPDATED AS APPLICABLE. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.
DEVICE REPORT FROM (B)(6) REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON AN UNKNOWN DATE, THE ORTHIKIT/SHORT TIME LOANER KIT DEPARTMENT RECEIVED AN INSTRUMENT BACK WITH A BROKEN TIP. THE CIRCUMSTANCES OF THE DEVICE BREAKAGE ARE UNKNOWN. IT IS UNKNOWN IF THERE IS PATIENT AND PROCEDURE INVOLVEMENT. THIS REPORT IS FOR A DRIVE SHAFT-MINIMUM 520 MM LENGTH-FOR USE WITH RIA. THIS IS REPORT 1 OF 1 FOR (B)(4).
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 637751 | DRIVE SHAFT-MINIMUM 520MM LENGTH-FOR USE WITH RIA | REAMER | HTO | OBERDORF SYNTHES PRODUKTIONS GMBH | H479823 | 07611819739208 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |