FDA Adverse Event Injury Summary report: N

PROXIMATE*HCS HEMORR CIR STAPL (EXACT CODE UNKNOWN

MDR report key: 8841311 · Received July 30, 2019

Report

Report Number
3005075853-2019-20879
Event Type
Injury
Date Received
July 30, 2019
Date of Event
January 1, 2009
Report Date
July 10, 2019
Manufacturer
ETHICON ENDO-SURGERY, LLC.
Product Code
GDW
Adverse Event
Yes
Report Source
Manufacturer report
Reporter Location
IT
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

(B)(4). DATE OF EVENT: PUBLICATION YEAR OF 2009. BATCH # UNK. THIS REPORT IS RELATED TO A JOURNAL ARTICLE; THEREFORE, NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE MANUFACTURING RECORDS CANNOT BE REVIEWED AS THE LOT/BATCH NUMBER HAS NOT BEEN PROVIDED. (B)(4).

Description of Event or Problem · 1

IT WAS REPORTED VIA LITERATURE ENTITLED: IS SIMPLE MUCOSAL RESECTION REALLY POSSIBLE? CONSIDERATIONS ABOUT HISTOLOGICAL FINDINGS AFTER STAPLED HEMORRHOIDOPEXY. AUTHOR : GABRIELE NALDINI & JACOPO MARTELLUCCI & LUCA MORALDI & NICOLA ROMANO & MAURO ROSSI. CITATION: INT J COLORECTAL DIS. 2009; 24: 537¿541. DOI: 10.1007/S00384-009-0636-Z. THE COMMON REMOVAL OF SMOOTH MUSCLE DURING STAPLED HEMORRHOIDECTOMY HAD RAISED CONCERNS ABOUT ITS EFFECTS ON POSTOPERATIVE ANORECTAL FUNCTION. THE PURPOSE OF THE STUDY IS TO CONFIRM THE HIGH FREQUENCY OF THE INVOLVEMENT OF SMOOTH MUSCLE FIBERS IN STAPLED HEMORRHOIDECTOMY AND TO DETERMINE ITS ASSOCIATION WITH POSTOPERATIVE FINDINGS. THIS RETROSPECTIVE STUDY EVALUATED 241 CASES (168 MALE AND 73 FEMALE PATIENTS; AGE RANGE: 22 TO 75 YEARS OLD) OF STAPLED HEMORRHOIDOPEXY TREATED FROM 2003 TO 2006. DURING THE SURGICAL PROCEDURE, A PPH01 OR PPH03 33-MM CIRCULAR STAPLER (ETHICON) WAS USED FOR ALL THE PROCEDURES. REPORTED COMPLICATIONS INCLUDED BLEEDING (N-14) WHICH REQUIRED REINTERVENTION FOR HEMOSTASIS IN 8 PATIENTS, ANAL PAIN (N-8) IN WHICH THE PAIN WAS TREATED WITH ORAL ANALGESIC AND LOCAL NITROGLYCERINE OINTMENTS, FLATUS INCONTINENCE (N-2), ABSCESS (N-2), HEMATOMA (N-1), AND RECURRENCE (N-11). THE PRESENCE OF SMOOTH MUSCLE FIBERS IN THE HISTOLOGICAL SPECIMENS DOES NOT SEEM TO INFLUENCE THE STAPLED HEMORRHOIDOPEXY OUTCOME REGARDING PAIN, BLEEDING, CONTINENCE, RECURRENCE, OR PATIENTS¿ SATISFACTION. MOREOVER, THE ANATOMICAL STRUCTURE OF THE ANAL REGION HAS ELEMENTS THAT KEEP THE MUCOSA AND THE SUBMUCOSA LINKED TO THE MUSCLE. IT IS CLEAR THAT THE SMOOTH MUSCLE PRESENCE IN THE RESECTED TISSUE IS NOT A TECHNICAL ERROR, BUT A COMMON FEATURE MAYBE CONNECTED TO A GOOD RESULT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
635928 PROXIMATE*HCS HEMORR CIR STAPL (EXACT CODE UNKNOWN STAPLE, IMPLANTABLE GDW ETHICON ENDO-SURGERY, LLC.

Patients

Seq Age Sex Outcome Treatment
1 Required Intervention