30K FOCUSED SPRAY SLIMLINE ULTRASONIC INSERT - 10S STRAIGHT
Report
- Report Number
- 2424472-2019-00113
- Event Type
- Malfunction
- Date Received
- July 17, 2019
- Report Date
- September 30, 2019
- Manufacturer
- DENTSPLY LLC
- Product Code
- ELC
- PMA / PMN Number
- K052334
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- CA
- Reporter Occupation
- DENTIST
Narratives
QTY 4 INSERTS RETURNED NOT IN ORIGINAL CLAM SHELL. VIBRATION. QTY 1 OF 4. INSERT 1 OF 4: P/N 1823234 QTY 4 INSERTS RETURNED NOT IN ORIGINAL CLAM SHELL. P/N 80395 DATE CODE: 18096,00004018 TIP LOT # HY. TEMPERATURE GAUGE: 7969 DUE 11/30/2019. TEMP: 87.4 MEETS SPEC. INDUCTANCE : 3.14MEETS SPEC. TIP CONDITION: BENT TIP DOES NOT MEET SPEC STACK CONDITION: MEETS SPEC. TESTED ON: G-136 GAGE ID# 9626, DUE DATE: 04/30/2020. SET PRESSURE: 35+-5 PSI WATER. FLOW RATE: 35 PSI MEETS SPEC. SPRAY PATTERN: MEETS SPEC. WATER LEAK: MEETS SPEC VIBRATION : MEETS SPEC. GRIP CONDITION: MEETS SPEC INSERT 2 OF 4: P/N 1823234 QTY 4 INSERTS RETURNED NOT IN ORIGINAL CLAM SHELL. P/N 80395 DATE CODE: 18096,00004018 TIP LOT # HY. COULD NOT TEST INSERT IS CLOGGED DOES NOT MEET SPEC. INDUCTANCE : 3.09MEETS SPEC. TIP CONDITION: BENT TIP DOES NOT MEET SPEC. STACK CONDITION: SLIGHT BENT IN LAMINATION STACK DOES NOT MEET SPEC. TESTED ON: G-136 GAGE ID# 9626, DUE DATE: 04/30/2020 SET PRESSURE: 35+-5 PSI WATER FLOW RATE: 0PSI DOES NOT MEET SPEC. SPRAY PATTERN: N / A INSERT IS CLOGGED. WATER LEAK: N/ A INSERT IS CLOGGED VIBRATION : MEETS SPEC. GRIP CONDITION: MEETS SPEC. INSERT 3 OF 4: P/N 1823234 QTY 4 INSERTS RETURNED NOT IN ORIGINAL CLAM SHELL. P/N 80395 DATE CODE: 18096,00004018, TIP LOT # HY. TEMPERATURE GAUGE: 7969, DUE 11/30/2019. TEMP: 80.3 MEETS SPEC. INDUCTANCE : 3.05MEETS SPEC. TIP CONDITION: BENT TIP DOES NOT MEET SPEC. STACK CONDITION: SLIGHT BENT IN LAMINATION STACK DOES NOT MEET SPEC. TESTED ON: G-136 GAGE ID# 9626, DUE DATE: 04/30/2020. SET PRESSURE: 35+-5 PSI WATER FLOW RATE: 35 PSI MEETS SPEC. SPRAY PATTERN: MEETS SPEC. WATER LEAK: MEETS SPEC VIBRATION : MEETS SPEC. GRIP CONDITION: MEETS SPEC. INSERT 4 OF 4: P/N 80395, DATE CODE: 19144,00027893, TIP LOT # IM. TEMPERATURE GAUGE: 7969 DUE 11/30/2019. TEMP: 89.2 MEETS SPEC. INDUCTANCE : 2.97MEETS SPEC. TIP CONDITION: MEETS SPEC. STACK CONDITION: SLIGHT BEND IN LAMINATION STACK DOES NOT MEET SPEC. TESTED ON: G-136 GAGE ID# 9626, DUE DATE: 04/30/2020, SET PRESSURE: 35+-5 PSI WATER FLOW RATE: 35 PSI MEETS SPEC. SPRAY PATTERN: MEETS SPEC. WATER LEAK: MEETS SPEC VIBRATION : MEETS SPEC. GRIP CONDITION: MEETS SPEC.
WHILE NO SERIOUS INJURY RESULTED IN THIS EVENT, THERE HAS BEEN A PREVIOUS REPORT RECEIVED WHERE THIS MALFUNCTION RESULTED IN A SERIOUS INJURY. THEREFORE, IT MUST BE PRESUMED THAT RECURRENCE OF THIS MALFUNCTION COULD POSSIBLY CAUSE OR CONTRIBUTE TO A SERIOUS INJURY OR REQUIRE MEDICAL OR SURGICAL INTERVENTION TO PRECLUDE SUCH. AS SUCH, THIS EVENT IS REPORTABLE PER 21 CFR PART 803. THIS REPORT IS FOR THE THIRD DEVICE. THE DEVICE IS AVAILABLE FOR EVALUATION, THOUGH HAS NOT BEEN RETURNED AS OF THIS REPORT. EVALUATION RESULTS WILL BE SUBMITTED AS THEY BECOME AVAILABLE.
IT WAS REPORTED THAT FOUR 30K FSI-SLI-10S INSERT TIPS WERE HEATING UP; NO INJURY RESULTED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 591960 | 30K FOCUSED SPRAY SLIMLINE ULTRASONIC INSERT - 10S STRAIGHT | SCALER, ULTRASONIC | ELC | DENTSPLY LLC | NA | 18096 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |