BD 60ML SYRINGE LUER-LOK TIP
Report
- Report Number
- 1911916-2019-00671
- Event Type
- Malfunction
- Date Received
- July 8, 2019
- Date of Event
- June 18, 2019
- Report Date
- June 21, 2019
- Manufacturer
- BECTON DICKINSON AND COMPANY
- Product Code
- FMF
- UDI-DI
- 30382903096535
- PMA / PMN Number
- K980987
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- KS
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
DATE OF EVENT: UNKNOWN. THE DATE RECEIVED BY MANUFACTURER HAS BEEN USED FOR THIS FIELD. INVESTIGATION SUMMARY: ONE (1) SAMPLE WAS RECEIVED FROM THE CUSTOMER FOR INVESTIGATION. THE SAMPLE WAS RETURNED WITH AN OPENED BLISTER PACK. THE SAMPLE WAS ANALYZED BY DRAWING 60ML OF A WATER/DYE SOLUTION INTO THE SYRINGE. NO LEAKAGE WAS OBSERVED. THE TIP OF THE SYRINGE WAS THEN BLOCKED AND THE PLUNGER WAS ATTEMPTED TO BE DEPRESSED. NO LEAKAGE WAS OBSERVED DURING THIS TEST. WHILE FAILURE MODE COULD NOT BE REPLICATED, LEAKAGE CAN BE CAUSED BY THE INTERACTION BETWEEN THE BARREL INSIDE DIAMETER, THE STOPPER OUTSIDE DIAMETER, AND PLUNGER ROD BAYONET OUTSIDE DIAMETER AND FORCES APPLIED DURING USE. THE SYRINGE IS MORE LIKELY TO LEAK WHEN FORCES ARE APPLIED TO THE PLUNGER ROD WHEN FULLY EXTENDED. A DEVICE HISTORY RECORD REVIEW WAS COMPLETED WITH ZERO DEFECTS FOUND. NO QUALITY NOTIFICATIONS WERE WRITTEN FOR THIS BATCH, NOR FOR THE ASSOCIATED ASSEMBLY BATCHES. INVESTIGATION CONCLUSION: A COMPLAINT HISTORY CHECK WAS PERFORMED AND THIS IS THE 1ST RELATED COMPLAINT REPORTED WITH THE DEFECT/CONDITION OF LEAKAGE PAST STOPPER FOR LOT #8220751 ITEM #309653. A DEVICE HISTORY RECORD (DHR) REVIEW WAS PERFORMED ON THE BATCH ASSOCIATED WITH THIS INVESTIGATION. THE DHR REVIEWS DID NOT REVEAL ANY DEFECTS OR ISSUES REPORTED AND NO QUALITY NOTIFICATIONS WERE ISSUED. ROOT CAUSE DESCRIPTION: WHILE FAILURE MODE COULD NOT BE REPLICATED, LEAKAGE CAN BE CAUSED BY THE INTERACTION BETWEEN THE BARREL INSIDE DIAMETER, THE STOPPER OUTSIDE DIAMETER, AND PLUNGER ROD BAYONET OUTSIDE DIAMETER AND FORCES APPLIED DURING USE. THE SYRINGE IS MORE LIKELY TO LEAK WHEN FORCES ARE APPLIED TO THE PLUNGER ROD WHEN FULLY EXTENDED.
IT WAS REPORTED THAT LEAKAGE OCCURRED DURING USE WITH A BD 60ML SYRINGE LUER-LOK¿ TIP. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER, "LEAKAGE THRU THE STOPPER."
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 560192 | BD 60ML SYRINGE LUER-LOK TIP | PISTON SYRINGE | FMF | BECTON DICKINSON AND COMPANY | 8220751 | 30382903096535 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Other |