FDA Adverse Event Malfunction Summary report: N

OMNIPOD INSULIN MANAGEMENT SYSTEM

MDR report key: 8727312 · Received June 24, 2019

Report

Report Number
3004464228-2019-05591
Event Type
Malfunction
Date Received
June 24, 2019
Date of Event
June 5, 2019
Report Date
June 6, 2019
Manufacturer
INSULET CORPORATION
Product Code
LZG
UDI-DI
20385081120033
PMA / PMN Number
K162296
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
MA, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 1

THE DEVICE WAS NOT RETURNED FOR EVALUATION. THE CANNULA HAD DISLODGED FROM THE INFUSION SITE. THIS CONDITION COULD INTERRUPT INSULIN DELIVERY AND CONTRIBUTE TO HYPERGLYCEMIA. LOT RELEASE RECORDS WERE REVIEWED AND THE PRODUCT LOT MET ALL ACCEPTANCE CRITERIA. OMNIPOD INSULIN MANAGEMENT SYSTEM ¿ USER GUIDE. MODEL: UST400. 17845-5A-AW REV B 09/17. CHANGING YOUR POD. CHAPTER 3 / PAGE 34. WARNINGS: CHECK OFTEN TO MAKE SURE THE POD AND SOFT CANNULA ARE SECURELY ATTACHED AND IN PLACE. A LOOSE OR DISLODGED CANNULA MAY INTERRUPT INSULIN DELIVERY. VERIFY THAT THERE IS NO WETNESS OR SCENT OF INSULIN, WHICH MAY INDICATE THAT THE CANNULA HAS DISLODGED. IF YOU OBSERVE BLOOD IN THE CANNULA, CHECK YOUR BLOOD GLUCOSE FREQUENTLY TO ENSURE THAT INSULIN DELIVERY HAS NOT BEEN AFFECTED. IF YOU EXPERIENCE UNEXPECTEDLY ELEVATED BLOOD GLUCOSE LEVELS, CHANGE YOUR POD. CHECKING YOUR BLOOD GLUCOSE. CHAPTER 4 / PAGE 36. WARNINGS: TEST RESULTS BELOW 70 MG/DL MEAN LOW BLOOD GLUCOSE (HYPOGLYCEMIA). TEST RESULTS GREATER THAN 250 MG/DL MEAN HIGH BLOOD GLUCOSE (HYPERGLYCEMIA). IF YOU GET RESULTS BELOW 70 MG/DL OR ABOVE 250 MG/DL, BUT DO NOT HAVE SYMPTOMS OF HYPOGLYCEMIA OR HYPERGLYCEMIA (SEE "LIVING WITH DIABETES" ON PAGE 115), REPEAT THE TEST. IF YOU HAVE SYMPTOMS OR CONTINUE TO GET RESULTS THAT FALL BELOW 70 MG/DL OR ABOVE 250 MG/DL, FOLLOW THE TREATMENT ADVICE OF YOUR HEALTHCARE PROVIDER.

Description of Event or Problem · 1

IT WAS REPORTED THAT THE PATIENT'S BLOOD GLUCOSE LEVELS REACHED OVER 400 MG/DL WHILE WEARING THE POD BETWEEN 4 AND 24 HOURS. THE ADHESIVE DETACHED FROM THE POD AND THE CANNULA DISLODGED FROM THE INFUSION SITE (LEG). AS TREATMENT, BOLUSED. THE PATIENT'S BLOOD GLUCOSE AND INSULIN HISTORY ARE AS FOLLOWS: TIME, BG(MG/DL); 1230, 300, BOLUS (UNKNOWN AMOUNT); 1445, 400 (CANNULA HAD DISLODGED).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
521355 OMNIPOD INSULIN MANAGEMENT SYSTEM PUMP, INFUSION, INSULIN LZG INSULET CORPORATION 19191 L44109 20385081120033

Patients

Seq Age Sex Outcome Treatment
1 5 YR