FLEXOCRIN 6/0 (0.7) 60CM DS9
Report
- Report Number
- 3003639970-2019-00451
- Event Type
- Malfunction
- Date Received
- June 5, 2019
- Date of Event
- March 19, 2019
- Report Date
- June 5, 2019
- Manufacturer
- B.BRAUN SURGICAL SA
- Product Code
- GAR
- PMA / PMN Number
- SEE H10
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- FR
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
AESCULAP INC. (IMPORTER) IS SUBMITTING THIS REPORT ON BEHALF OF B. BRAUN SURGICAL S.A. (MANUFACTURER). EXEMPTION NUMBER: E2014012. REPORTED DEVICE NOT MARKETED IN THE U.S., HOWEVER, SIMILAR DEVICES OR DEVICES THAT SHARE COMPONENTS, RAW MATERIALS, PROCESS METHODS OR OTHER TECHNOLOGICAL CHARACTERISTICS ARE REGISTERED WITHIN THE U.S. K990090. INVESTIGATION: SAMPLES RECEIVED: (B)(4) UNOPENED POUCHES AND ONE NEEDLE WITHOUT PACKAGING (NEITHER THREAD). ANALYSIS AND RESULTS: THERE ARE NO PREVIOUS COMPLAINTS OF THE SAME CODE-BATCH. WE MANUFACTURED AND DISTRIBUTED IN THE MARKET (B)(4) UNITS OF THIS CODE-BATCH. THERE ARE NO UNITS IN OUR STOCK. WE HAVE RECEIVED (B)(4) CLOSED SAMPLES AND A DETACHED NEEDLE (USED). WE HAVE TESTED THE NEEDLE ATTACHMENT STRENGTH OF THE 20 CLOSED SAMPLES RECEIVED AND THE RESULTS FULFIL THE REQUIREMENTS OF THE EUROPEAN PHARMACOPOEIA (EP):0.28 KGF IN AVERAGE AND 0.218 KGF IN MINIMUM (EP REQUIREMENTS: 0.17 KGF IN AVERAGE AND 0.082 KGF IN MINIMUM). REVIEWED THE BATCH MANUFACTURING RECORD, THIS PRODUCT HAD A NORMAL PROCESS AND THE RESULTS DURING THE PROCESS FULFIL USP/EP AND B.BRAUN SURGICAL REQUIREMENTS. FINAL CONCLUSION: ALTHOUGH THE RESULTS OF THE CLOSED SAMPLES RECEIVED FULFIL THE SPECIFICATIONS OF EUROPEAN PHARMACOPOEIA/ B. BRAUN SURGICAL SPECIFICATIONS, WE TAKE NOTE OF THIS INCIDENCE IN ORDER TO ASSESS IF NEW OR ADDITIONAL ACTIONS ARE NEEDED. ACTIONS ON PRODUCT DISTRIBUTED OF THIS REFERENCE/BATCH: BASED ON THE CONCLUSION DERIVED FROM INVESTIGATION, IT IS NOT REQUIRED TO MAKE ACTIONS IN DISTRIBUTED PRODUCT. NO CORRECTIVE/PREVENTIVE ACTIONS NEEDED.
IT WAS REPORTED THE NEEDLE DETACHED. THE REPORTER INDICATED THAT THE NEEDLE BECAME DETACHED FROM THE THREAD. NO OTHER INFORMATION HAS BEEN PROVIDED. ADDITIONAL INFORMATION HAS BEEN REQUESTED, HOWEVER, NOT YET RECEIVED.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 463719 | FLEXOCRIN 6/0 (0.7) 60CM DS9 | OTHER SUTURE | GAR | B.BRAUN SURGICAL SA | C0865800 | 617507V006 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |