FDA Adverse Event Malfunction Summary report: N

PACKAGE,350P,PP01,EN,350-BAS-US-10

MDR report key: 8665956 · Received June 4, 2019

Report

Report Number
3004123209-2019-00205
Event Type
Malfunction
Date Received
June 4, 2019
Date of Event
May 1, 2019
Report Date
August 19, 2019
Manufacturer
HEARTSINE TECHNOLOGIES LTD
Product Code
MKJ
UDI-DI
M727SAM350P
PMA / PMN Number
P160008
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
MI, US
Reporter Occupation
OTHER

Narratives

Additional Manufacturer Narrative · 0

EXEMPTION NUMBER E2015058. HEARTSINE TECHNOLOGIES LTD (MANUFACTURER) IS SUBMITTING THE REPORT ON BEHALF OF HEARTSINE TECHNOLOGIES LLC (IMPORTER).

Additional Manufacturer Narrative · 0

THE DEVICE HISTORY RECORDS FOR THE SAM 350P DEVICE AND PAD-PAK WERE REVIEWED AND THIS CONFIRMED THAT ALL MANUFACTURING AND QUALITY CHECKS AND TEST HAD BEEN SUCCESSFULLY COMPLETED. THE SAM 350P PASSED ¿OUT QAT FROM HEARTSINE TECHNOLOGIES ON THE 6TH FEBRUARY 2018. THE DEVICE PERFORMED TO SPECIFICATION DURING INVESTIGATION. NO FAULTS WERE FOUND ON THE DEVICE, INCLUDING MEASUREMENTS ON THE MEMBRANE AROUND THE GREEN STATUS LED AND THE RED STATUS LED . NO FAULT WAS FOUND ON THE STATUS LED LINES OF THE MEMBRANE, OR THEIR ASSOCIATED CIRCUITRY ON THE PCBA. THE TRACKS WERE INSPECTED FROM UNDERNEATH WITH NO ABNORMALITIES OBSERVED. ADDITIONALLY NO FAILS WERE LOGGED IN THE HISTORY LOG OF THE DEVICE. THE DEVICE WAS TEMPERATURE CYCLED FROM 0-50°C FOR 48 HOURS WHILE PERFORMING A SELF-TEST EVERY 20 MINUTES. ADDITIONALLY, STRESS TESTING WAS CARRIED OUT AT 50°C 95%RH FOR 5 DAYS WHILE PERFORMING A SELF-TEST EVERY 20 MINUTES. DURING THIS TIME THE GREEN STATUS LED FLASHED THROUGHOUT AND NO FAILURE CHIRP COULD BE HEARD FROM THE DEVICE. THIS COMBINED TESTING EQUATES TO APPROXIMATELY 9.5 YEARS OF NORMAL USE WITHOUT FAULT. IT IS THE POLICY OF HEARTSINE NOT TO REFURBISH DEVICES WHICH HAVE BEEN RETURNED FROM THE FIELD, AFTER INVESTIGATION, THEREFORE THIS DEVICE SHALL BE SCRAPPED AND REPLACED WITH ANOTHER DEVICE OF THE SAME MODEL.

Description of Event or Problem · 0

DEVICE PURCHASED A UNIT ONLY ABOUT 6 MONTHS AGO AND IT IS CHIRPING, BUT FLASHING GREEN. THERE WAS NO PATIENT INVOLVED IN THIS EVENT.

Description of Event or Problem · 0

DEVICE PURCHASED A UNIT ONLY ABOUT 6 MONTHS AGO AND IT IS CHIRPING, BUT FLASHING GREEN. THERE WAS NO PATIENT INVOLVED IN THIS EVENT.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
461816 PACKAGE,350P,PP01,EN,350-BAS-US-10 AUTOMATED EXTERNAL DEFIBRILLATOR MKJ HEARTSINE TECHNOLOGIES LTD M727SAM350P

Patients

Seq Age Sex Outcome Treatment
1