PACKAGE,350P,PP01,EN,350-BAS-US-10
Report
- Report Number
- 3004123209-2019-00205
- Event Type
- Malfunction
- Date Received
- June 4, 2019
- Date of Event
- May 1, 2019
- Report Date
- August 19, 2019
- Manufacturer
- HEARTSINE TECHNOLOGIES LTD
- Product Code
- MKJ
- UDI-DI
- M727SAM350P
- PMA / PMN Number
- P160008
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- MI, US
- Reporter Occupation
- OTHER
Narratives
EXEMPTION NUMBER E2015058. HEARTSINE TECHNOLOGIES LTD (MANUFACTURER) IS SUBMITTING THE REPORT ON BEHALF OF HEARTSINE TECHNOLOGIES LLC (IMPORTER).
THE DEVICE HISTORY RECORDS FOR THE SAM 350P DEVICE AND PAD-PAK WERE REVIEWED AND THIS CONFIRMED THAT ALL MANUFACTURING AND QUALITY CHECKS AND TEST HAD BEEN SUCCESSFULLY COMPLETED. THE SAM 350P PASSED ¿OUT QAT FROM HEARTSINE TECHNOLOGIES ON THE 6TH FEBRUARY 2018. THE DEVICE PERFORMED TO SPECIFICATION DURING INVESTIGATION. NO FAULTS WERE FOUND ON THE DEVICE, INCLUDING MEASUREMENTS ON THE MEMBRANE AROUND THE GREEN STATUS LED AND THE RED STATUS LED . NO FAULT WAS FOUND ON THE STATUS LED LINES OF THE MEMBRANE, OR THEIR ASSOCIATED CIRCUITRY ON THE PCBA. THE TRACKS WERE INSPECTED FROM UNDERNEATH WITH NO ABNORMALITIES OBSERVED. ADDITIONALLY NO FAILS WERE LOGGED IN THE HISTORY LOG OF THE DEVICE. THE DEVICE WAS TEMPERATURE CYCLED FROM 0-50°C FOR 48 HOURS WHILE PERFORMING A SELF-TEST EVERY 20 MINUTES. ADDITIONALLY, STRESS TESTING WAS CARRIED OUT AT 50°C 95%RH FOR 5 DAYS WHILE PERFORMING A SELF-TEST EVERY 20 MINUTES. DURING THIS TIME THE GREEN STATUS LED FLASHED THROUGHOUT AND NO FAILURE CHIRP COULD BE HEARD FROM THE DEVICE. THIS COMBINED TESTING EQUATES TO APPROXIMATELY 9.5 YEARS OF NORMAL USE WITHOUT FAULT. IT IS THE POLICY OF HEARTSINE NOT TO REFURBISH DEVICES WHICH HAVE BEEN RETURNED FROM THE FIELD, AFTER INVESTIGATION, THEREFORE THIS DEVICE SHALL BE SCRAPPED AND REPLACED WITH ANOTHER DEVICE OF THE SAME MODEL.
DEVICE PURCHASED A UNIT ONLY ABOUT 6 MONTHS AGO AND IT IS CHIRPING, BUT FLASHING GREEN. THERE WAS NO PATIENT INVOLVED IN THIS EVENT.
DEVICE PURCHASED A UNIT ONLY ABOUT 6 MONTHS AGO AND IT IS CHIRPING, BUT FLASHING GREEN. THERE WAS NO PATIENT INVOLVED IN THIS EVENT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 461816 | PACKAGE,350P,PP01,EN,350-BAS-US-10 | AUTOMATED EXTERNAL DEFIBRILLATOR | MKJ | HEARTSINE TECHNOLOGIES LTD | M727SAM350P |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 |