FDA Adverse Event Malfunction Summary report: N

ISTENT TRABECULAR MICRO-BYPASS

MDR report key: 8633725 · Received May 22, 2019

Report

Report Number
2032546-2019-00072
Event Type
Malfunction
Date Received
May 22, 2019
Date of Event
April 26, 2019
Report Date
May 23, 2019
Manufacturer
GLAUKOS CORPORATION
Product Code
OGO
PMA / PMN Number
P080030
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
CA, US
Reporter Occupation
PHYSICIAN

Narratives

Additional Manufacturer Narrative · 0

ATTACHED ARTICLE REFERENCED IN THE INITIAL REPORT. MFR# REFERENCE: (B)(4).

Additional Manufacturer Narrative · 1

DATE OF EVENT: ESTIMATED BASED TRIAL START DATE AND PUBLICATION DATE. THE DEVICES WERE NOT AVAILABLE; THEREFORE, PRODUCT TESTING ON THESE ACTUAL DEVICES COULD NOT BE PERFORMED. THE DEVICE IDENTIFIERS WERE NOT PROVIDED; THEREFORE, THE DEVICE HISTORY RECORDS AND COMPLAINT HISTORY RECORDS FOR THIS DEVICE LOT NUMBER COULD NOT BE REVIEWED. A REVIEW OF THE DEVICE LABELING WAS COMPLETED. STENT OBSTRUCTION IS IDENTIFIED IN THE LABELING AS A KNOWN INHERENT RISK OF TRABECULAR MICRO-BYPASS STENT PROCEDURE. THE IFU ADEQUATELY PROVIDES INSTRUCTIONS FOR STENT IMPLANTATION, PRECAUTIONS, AND WARNINGS FOR THE PROPER USE AND HANDLING OF THE DEVICE. THE IFU STATES THAT THE SAFETY AND EFFECTIVENESS OF THE ISTENT INJECT TRABECULAR MICRO BYPASS SYSTEM HAS NOT BEEN ESTABLISHED FOR IMPLANTATION OF MORE THAN TWO STENTS IN ONE EYE. MFR# REFERENCE: (B)(4). PLEASE REFERENCE 2032546-2019-00071 FOR ADVERSE EVENT REPORTED IN TRABECULAR MICRO BYPASS STENT GROUP.

Description of Event or Problem · 1

THE FOLLOWING WAS REPORTED THROUGH REVIEW OF AN ARTICLE. IN THE TWO (2) ISTENTS GROUP, THERE WAS ONE (1) CASE OF BCVA LOSS OF TWO (2) LINES, FOUR (4) CASES OF IOP ELEVATION OVER BASELINE AND DEVICE OBSTRUCTIONS (UNSPECIFIED QUANTITY) RELATED TO IRIS OR OTHER TISSUE ADHESION. TWO (2) SUBJECTS REQUIRED SUBSEQUENT GLAUCOMA SURGERY DUE TO UNCONTROLLED IOP DESPITE MAXIMUM MEDICAL THERAPY AT AN UNKNOWN POSTOP PERIOD. THIS IS A PROSPECTIVE STUDY TO COMPARE THE EFFICACY OF DIFFERENT MIGS DEVICES FOR REDUCING INTRAOCULAR PRESSURE (IOP) AND MEDICATIONS IN OPEN-ANGLE GLAUCOMA (OAG). THIS REPORT REFERENCES THE STENT OBSTRUCTION OCCURRING IN TRABECULAR MICRO BYPASS STENT GROUP. ADDITIONAL INFORMATION IS BEING REQUESTED.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
424986 ISTENT TRABECULAR MICRO-BYPASS INTRAOCULAR PRESSURE LOWERING IMPLANT OGO GLAUKOS CORPORATION

Patients

Seq Age Sex Outcome Treatment
1 66 YR