HEARTSINE SAMARITAN 300P AND PAD-PAK
Report
- Report Number
- 3004123209-2019-00202
- Event Type
- Malfunction
- Date Received
- May 21, 2019
- Date of Event
- May 1, 2019
- Report Date
- February 4, 2020
- Manufacturer
- HEARTSINE TECHNOLOGIES LTD
- Product Code
- MKJ
- PMA / PMN Number
- K014067
- Removal / Correction Number
- Z-0124-2013
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- RE
- Reporter Occupation
- OTHER
Narratives
THE DEVICE HISTORY RECORDS FOR THE SAM 300P DEVICE AND THE PAD-PAK WERE REVIEWED, AND THIS CONFIRMED THAT ALL MANUFACTURING AND QUALITY CHECKS AND TEST HAD BEEN SUCCESSFULLY COMPLETED, THE DEVICE WAS PREVIOUSLY RETURNED TO HEATSINE FOR UPGRADE. THE UPPER CASE ASSEMBLY AND MEMBRANE WERE REWORKED, AND THE DEVICE WAS RETESTED. THE SAM 300P LAST PASSED ¿OUT QAT FROM HEARTSINE TECHNOLOGIES ON THE (B)(6) 2014. THE DEVICE WAS RETURNED WITH A REPORTED FAULT OF A SPEAKER MALFUNCTION DETECTED DURING SAVER EVO TESTING. INFORMATION FROM THE HISTORY LOG SHOWED THE DEVICE HAD PERFORMED AS PER SPECIFICATION FROM INSTALLATION UP UNTIL THE LAST LOG ENTRY ON THE (B)(6) 2019. DURING TESTING AT HEARTSINE, THE DEVICE PASSED THE ¿AUDIBLE BEEP¿ TEST WITHIN THE SAVER EVO DIAGNOSTIC TOOL MULTIPLE TIMES WITHOUT FAULT. FURTHERMORE, THE DEVICE ISSUED ALL SPECIFIED AUDIO PROMPTS THROUGHOUT THE INVESTIGATION, WITH NO OMISSIONS, DISTORTION OR OTHER ABNORMALITIES IDENTIFIED. MEASUREMENTS WERE TAKEN ON THE SPEAKER, USB POWER CIRCUITRY AND SPEECH CIRCUITRY, WITH NO FAULT FOUND. THE DEVICE WAS LEFT IN THE HUMIDITY CHAMBER FOR 5 DAYS AT 50°C 95%RH. THE UNIT WAS POWER CYCLED MULTIPLE TIMES DURING AND AFTER THIS STRESS TESTING, ISSUING THE NORMAL ADVISORY SPEECH PROMPTS ON EACH OCCASION AND PASSING THE AUDIBLE BEEP TEST WITHIN SAVER EVO DIAGNOSTIC TOOL. FURTHERMORE, NO MEASURABLE FAULT WAS IDENTIFIED ON THE UNIT, EVEN AFTER THE STRESS OF ELEVATED TEMPERATURE AND HUMIDITY. THE INVESTIGATION WAS UNABLE TO CONFIRM THE REPORTED FAULT. THE SAVER EVO TEST REQUIRES A USB CABLE TO BE CONNECTED TO THE USB PORT ON THE USER¿S PC. THE INVESTIGATION WAS UNABLE TO VERIFY EITHER THE USERS USB CABLE OR THE USB PORT ON THE USER¿S PC WHICH MAY HAVE CONTRIBUTED TO THE REPORTED FAILURE. THE RETURNED SAM 300P IS NOW OUTSIDE OF ITS WARRANTY PERIOD AND WILL BE SCRAPPED.
EXEMPTION NUMBER E2015058. HEARTSINE TECHNOLOGIES LTD (MANUFACTURER) IS SUBMITTING THE REPORT ON BEHALF OF HEARTSINE TECHNOLOGIES LLC (IMPORTER).
SPEAKER IS MALFUNCTIONIN. THERE WAS NO PATIENT INVOLVED IN THIS EVENT.
SPEAKER IS MALFUNCTION. THERE WAS NO PATIENT INVOLVED IN THIS EVENT.