NCIRCLE TIPLESS STONE EXTRACTOR
Report
- Report Number
- 1820334-2019-01160
- Event Type
- Malfunction
- Date Received
- May 20, 2019
- Date of Event
- April 29, 2019
- Report Date
- June 25, 2019
- Manufacturer
- COOK INC
- Product Code
- FFL
- UDI-DI
- 00827002462069
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- TW
- Reporter Occupation
- NURSE
Narratives
INVESTIGATION ¿ EVALUATION. A VISUAL INSPECTION AND FUNCTIONAL TESTING OF THE RETURNED DEVICE WAS CONDUCTED. A DOCUMENT BASED INVESTIGATION WAS ALSO COMPLETED INCLUDING A REVIEW OF COMPLAINT HISTORY, THE DEVICE HISTORY RECORD, INSTRUCTIONS FOR USE, MANUFACTURING INSTRUCTIONS, AND QUALITY CONTROL DATA. THE COMPLAINANT RETURNED ONE DEVICE FOR INVESTIGATION. THE RETURNED PACKAGING CONFIRMS THE REPORTED LOT NUMBER. THE DEVICE WAS RETURNED WITH THE HANDLE AND BASKET FORMATION IN THE OPEN POSITION. VISUAL EXAMINATION NOTED NO KINKS IN THE BASKET SHEATH. FUNCTIONAL TESTING DETERMINED THE HANDLE ACTUATES THE BASKET FORMATION SMOOTHLY. THE RETURNED DEVICE FUNCTIONS AS INTENDED. A REVIEW OF THE DEVICE HISTORY RECORD SHOWS THERE ARE NO NON-CONFORMANCES. NO OTHER COMPLAINTS ARE ASSOCIATED WITH THE COMPLAINT DEVICE LOT NUMBER. THE INSTRUCTIONS FOR USE (IFU) PROVIDES THE FOLLOWING RELEVANT INFORMATION TO THE USER. PRECAUTION: ENCLOSE THE DEVICE IN THE SHEATH BEFORE REMOVING FROM THE TRAY/HOLDER. PRECAUTION: DO NOT USE EXCESSIVE FORCE TO MANIPULATE THIS DEVICE. DAMAGE TO THE DEVICE MAY OCCUR. THE RETURNED DEVICE FUNCTIONED AS INTENDED. THE CUSTOMER¿S DIFFICULTY COULD NOT BE RECREATED DURING THE INVESTIGATION. BASED ON THE INVESTIGATION EVALUATION, THERE IS NO INDICATION THAT A DESIGN OR PROCESS RELATED FAILURE MODE CONTRIBUTED TO THIS EVENT. CURRENT CONTROLS FOR MANUFACTURING ARE IN PLACE TO ASSURE FUNCTIONALITY AND DEVICE INTEGRITY PRIOR TO SHIPPING. REVIEW OF PRODUCTION AND QUALITY DOCUMENTATION DID NOT OBSERVE ANY SPECIFIC ISSUES WITH CURRENT MANUFACTURING OR QUALITY CONTROLS THAT MAY HAVE CONTRIBUTED TO THIS INCIDENT. THE RETURNED DEVICE WAS FOUND TO BE FUNCTIONAL, WITH THE BASKET OPENING AND CLOSING WHEN THE HANDLE WAS FUNCTIONED. THERE WAS NO DAMAGE TO THE DEVICE. THE COMPLAINT COULD NOT BE CONFIRMED. PER THE QUALITY ENGINEERING RISK ASSESSMENT, NO FURTHER ACTION IS WARRANTED. THE APPROPRIATE INTERNAL PERSONNEL HAVE BEEN NOTIFIED AND WE WILL CONTINUE TO MONITOR FOR SIMILAR COMPLAINTS. THIS REPORT IS REQUIRED BY THE FDA UNDER 21 CFR PART 803. THIS REPORT IS BASED ON UNCONFIRMED INFORMATION SUBMITTED BY OTHERS. NEITHER THE SUBMISSION OF THIS REPORT NOR ANY STATEMENT MADE IN IT IS INTENDED TO BE AN ADMISSION THAT ANY COOK DEVICE IS DEFECTIVE OR MALFUNCTIONED; THAT A DEATH OR SERIOUS INJURY OCCURRED; OR THAT ANY COOK DEVICE CAUSED OR CONTRIBUTED TO; OR IS LIKELY TO CAUSE OR CONTRIBUTE TO A DEATH OR SERIOUS INJURY IF A MALFUNCTION OCCURRED.
THERE HAS BEEN NO NEW EVENT INFORMATION RECEIVED SINCE THE LAST REPORT WAS SUBMITTED.
PMA/510(K) #: EXEMPT. THIS REPORT INCLUDES INFORMATION KNOWN AT THIS TIME. A FOLLOW UP REPORT WILL BE SUBMITTED SHOULD ADDITIONAL RELEVANT INFORMATION BECOME AVAILABLE.
WHEN THE PHYSICIAN WENT TO USE THE NTSE-015115 TO GRAB A SALIVARY STONE, HE TRIED TO OPEN AND CLOSE BASKET BEFORE ENTERING INTO THE PATIENT'S BODY. HE FOUND THE EXTRACTOR CANNOT OPEN AND CLOSE SMOOTHLY. THEN HE USED A DIFFERENT METHOD TO GRAB THE STONE. THE PATIENT OUTCOME WAS GOOD. ACCORDING TO THE INSTRUCTIONS FOR USE (IFU): DEVICE DESCRIPTION THE NCIRCLE, NCOMPASS, AND NFORCE STONE EXTRACTORS ARE 3- OR 4-WIRE NITINOL BASKETS AVAILABLE IN A RANGE OF FRENCH SIZES, LENGTHS, AND BASKET DIAMETERS. INTENDED USE: THE NCIRCLE, NCOMPASS, AND NFORCE STONE EXTRACTORS ARE INTENDED FOR STONE MANIPULATION AND REMOVAL IN THE URINARY TRACT.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 418498 | NCIRCLE TIPLESS STONE EXTRACTOR | FFL DISLODGER, STONE, BASKET, URETERAL, METAL | FFL | COOK INC | G46206 | 9278930 | 00827002462069 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 79 YR | SALIVARY SCOPE| SALIVARY SCOPE |