MOD ARTHRO 0 DEG LCK COLLAR
Report
- Report Number
- 0001825034-2019-02184
- Event Type
- Injury
- Date Received
- May 15, 2019
- Date of Event
- April 13, 2019
- Report Date
- January 31, 2020
- Manufacturer
- ZIMMER BIOMET, INC.
- Product Code
- HSB
- PMA / PMN Number
- K042049
- Removal / Correction Number
- N/A
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- WV, US
- Reporter Occupation
- PHYSICIAN
Narratives
UPON REASSESSMENT OF THE REPORTED EVENT, IT WAS DETERMINED THAT THIS PRODUCT WAS REPORTED IN ERROR AND DID NOT CONTRIBUTED TO THE REPORTED EVENT. THE INITIAL REPORT SUBMITTED NEEDS TO BE VOIDED.
FOLLOWING INVESTIGATION, IMPLANT WAS DETERMINED TO NOT BE SUBJECT OF COMPLAINT.
NO FURTHER EVENT INFORMATION AVAILABLE AT THE TIME OF THIS REPORT.
(B)(4). MULTIPLE MDR REPORTS WERE FILED FOR THIS EVENT, PLEASE SEE ASSOCIATED REPORTS: 0001825034-2019-02183, 0001825034-2019-02185, AND 0001825034-2019-02186. UDI: (B)(4). CONCOMITANT MEDICAL PRODUCTS: MOD ARTHRO NL 3CM DIASL CNCTR, CATALOG#: CP260607, LOT#: NI. OSS SEGMENTAL STACKING ADAPTER, CATALOG# 150483, LOT#: 302180. UNKNOWN SCREW, CATALOG#: NI, LOT#: NI. CPS LG SPDL WITH PINS 800LBF, CATALOG#: 178358, LOT#: 502600. CPS LG SPDL WITH PINS 800LBF, CATALOG#: 178404, LOT#: 213070. CPS TRANSVERSE PIN 6PK 32MM, CATALOG#: 178527, LOT#: 134880. CPS CENTERING SLEEVE 18MM, CATALOG#: 178540, LOT#: 131070. CPS NUT CO-CR-MO ALLOY, CATALOG#: 178512, LOT#: 498690. CPS ANCHOR PLUG 10MM, CATALOG#: 178400, LOT#: 182490. CPS SM SPDL WITH PINS 800LBF, CATALOG#: 178355, LOT#: 717020. CPS/OSS 5CM TPR ADAPT W/OSS SC, CATALOG#: 178711, LOT#: 433100. CPS NUT CO-CR-MO ALLOY, CATALOG#: 178512, LOT#: 222820. CPS TRANSVERSE PIN 6PK 32MM, CATALOG#: 178527, LOT#: 742300. CPS CENTERING SLEEVE 15MM, CATALOG#: 178537, LOT#: 935290. CPS/OSS 5CM TPR ADAPT W/OSS SC, CATALOG#: 178711, LOT#: 250750. MOD ARTHRO NL 3CM DIASL CNCTR, CATALOG#: CP260607, LOT#: 580090. OSS 4CM DIAPHYSEAL SEGMENT, CATALOG#: 150482, LOT#: 801580. OSS SEGMENTAL STACKING ADAPTER, CATALOG#: 150483, LOT#: 580530. MOD ARTHRO 0 DEG LCK COLLAR, CATALOG#: CP260600, LOT#: 491090. MOD ARTHRO NL 3CM DIASL CNCTR, CATALOG#: CP260607, LOT#: 181570. PRODUCT HAS BEEN RECEIVED BY ZIMMER BIOMET AND THE INVESTIGATION IS IN PROCESS. ONCE THE INVESTIGATION HAS BEEN COMPLETED, A FOLLOW-UP MDR WILL BE SUBMITTED.
IT WAS REPORTED THAT PATIENT UNDERWENT INITIAL KNEE ARTHROPLASTY. SUBSEQUENTLY, UNDERWENT A REVISION DUE THE IMPLANT FRACTURED WHILE WALKING FOUR (4) YEAR FIVE (5) MONTHS POST PRIMARY IMPLANTATION. PATIENT WAS WALKING FIVE MILE PER DAY.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 405289 | MOD ARTHRO 0 DEG LCK COLLAR | PLATE, FIXATION | HSB | ZIMMER BIOMET, INC. | N/A | 341290 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 38 YR | Hospitalization| R | SEE H10 |