FDA Adverse Event Injury Summary report: N

PLATE,FIXATION,BONE

MDR report key: 8609471 · Received May 14, 2019

Report

Report Number
8030965-2019-63950
Event Type
Injury
Date Received
May 14, 2019
Date of Event
October 19, 2017
Report Date
April 17, 2019
Manufacturer
OBERDORF SYNTHES PRODUKTIONS GMBH
Product Code
HRS
Adverse Event
Yes
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
IT
Reporter Occupation
OTHER HEALTH CARE PROFESSIONAL

Narratives

Additional Manufacturer Narrative · 1

THIS REPORT IS FOR UNKNOWN PLATE. PART#, LOT# AND UDI # IS NOT AVAILABLE. DEVICE IS NOT EXPECTED TO BE RETURNED FOR MANUFACTURER REVIEW/INVESTIGATION. THIS REPORT IS FOR UNKNOWN PLATE. PMA/510(K) NUMBER IS NOT AVAILABLE. (B)(4). PRODUCT WAS NOT RETURNED. DEVICE HISTORY RECORDS REVIEW COULD NOT BE COMPLETED WITHOUT LOT NUMBER. BASED ON THE INFORMATION AVAILABLE, IT HAS BEEN DETERMINED THAT NO CORRECTIVE AND PREVENTATIVE ACTION IS PROPOSED. THIS COMPLAINT WILL BE ACCOUNTED FOR AND MONITORED VIA POST MARKET SURVEILLANCE ACTIVITIES. IF ADDITIONAL INFORMATION IS MADE AVAILABLE, THE INVESTIGATION WILL BE UPDATED AS APPLICABLE. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE. (B)(4).

Description of Event or Problem · 1

THIS REPORT IS BEING FILED AFTER THE REVIEW OF THE FOLLOWING JOURNAL ARTICLE: MARESCA, A. ET AL (2017, WHY A SURGICALLY TREATED HUMERAL SHAFT FRACTURE BECAME A NONUNION: REVIEW OF 11 YEARS IN TWO TRAUMA CENTERS, MUSCULOSKELETAL SURGERY DECEMBER 2017, VOLUME 101, SUPPLEMENT 2, PAGES 105-112 (ITALY) DOI 10.1007/S12306-017-0509-5. THIS RETROSPECTIVE STUDY AIMS TO EVALUATE NONUNION CAUSES OF SURGICALLY TREATED HUMERAL SHAFT FRACTURES IN TWO DIFFERENT TRAUMA CENTERS. FROM 2005 TO 2015, A TOTAL OF 327 HUMERAL SHAFT FRACTURES SURGICALLY TREATED HAVE BEEN EXAMINED. AMONG THESE, 224 (114 MALE 110 FEMALE) WITH AN AVERAGE AGE OF (B)(6) YEAR OLD WERE TREATED AT MAGGIORE HOSPITAL OF BOLOGNA FROM JANUARY 2005 TO DECEMBER 2011. SIXTEEN (16) WERE OPEN FRACTURES. ONE HUNDRED AND SIXTY-FIVE(165) CASES WERE TREATED WITH A 4.5 STRAIGHT PLATE FIXATION,1 CASE WITH A 3.5 STRAIGHT PLATE, 50 CASES WITH AN ANATOMICAL SITE-SPECIFIC PROXIMAL HUMERAL 3.5-MM LCP PLATE. FIFTEEN NONUNION WAS OBSERVED. FROM JANUARY 2012 TO DECEMBER 2015, 103 HUMERAL DIAPHYSIS FRACTURE CASES (40 MALE 63 FEMALE) WITH AN AVERAGE AGE OF 64 YEAR OLD WERE TREATED AT RIUNITI HOSPITALS OF ANCONA. FORTY TWO (42) CASES WERE TREATED WITH A 4.5 STRAIGHT PLATE, THIRTY ONE (31) CASES WITH AN ANATOMICAL SITE-SPECIFIC PROXIMAL HUMERAL 3.5-MM LCP PLATE (SYNTHES, PAOLI, PA, USA) 4 NONUNION WERE OBSERVED. THE FOLLOWING COMPLICATIONS WERE REPORTED AS FOLLOWS: AT MAGGIORE HOSPITAL OF BOLOGNA: A CASE OF A (B)(6) YEAR OLD WITH AN INITIAL OF BR HAD AN INITIAL TREATMENT USING A 3.5 MM LCP PLATE 6 MONTHS AFTER HAD SCREW BREAKAGE . .A SECOND TREATMENT WAS DONE WITH USING A 4.5 PLATE AND BONE GRAFT. THERE WAS A CONSOLIDATION. A CASE OF A (B)(6) YEAR OLD WITH AN INITIAL OF DA HAD AN INITIAL TREATMENT USING A 3.5 MM LCP PLATE, 5 MONTHS AFTER HAD PLATE BREAKAGE. SECOND TREATMENT A 3.5 ANATOMICAL PROXIMAL HUMERAL 3.5 MM LCP PLATE AND GRAFT WAS USED. THERE WAS CONSOLIDATION. A CASE OF A (B)(6) YEAR OLD WITH AN INITIAL OF MA HAD AN INITIAL TREATMENT USING A 3.5 MM LCP PLATE, AFTER 6 MONTHS HAD FAILED CONSOLIDATION. A SECOND TREATMENT WAS DONE WITH USING A 4.5 PLATE AND BONE GRAFT. THERE WAS A SUCCESSFUL CONSOLIDATION. A CASE OF AN (B)(6) YEAR WITH AN INITIAL OF PC HAD INITIAL TREATMENT USING A 3.5 MM LCP PLATE, 5 MONTHS AFTER HAD PLATE AND SCREW LOOSENING. SECOND TREATMENT WAS DONE USING A 4.5 PLATE AND BONE GRAFT. THERE WAS NO CONSOLIDATION AND AFTER 5 MONTHS A CUTOUT OF THE PROXIMAL SCREWS FOR OSTEOPOROTIC BONE WAS DONE. AT RIUNITI HOSPITAL : A CASE OF AN (B)(6) YEAR OLD WITH AN INITIAL OF BT HAD AN INITIAL TREATMENT USING 3.5 MM LCP PLATE,8 MONTHS AFTER HAD LOSS OF BONE SUBSTANCE FRAGMENT RESORPTION DUE TO SCREWS BREAKAGE . SECOND TREATMENT WAS DONE USING A 3.5 PHILOS AND BONE GRAFT. THERE WAS A CONSOLIDATION. A CASE OF AN (B)(6) YEAR OLD WITH AN INITIAL OF DG HAD AN INITIAL TREATMENT USING A 3.5 MM LCP PLATE, 12 MONTHS AFTER HAD FRAGMENT RESORPTION DUE TO PLATE BREAKAGE. SECOND TREATMENT WAS DONE USING A 4.5 PLATE AND BONE GRAFT. THERE WAS CONSOLIDATION. A CASE OF A (B)(6) YEAR OLD HAD WITH AN INITIAL OF SE HAD AN INITIAL TREATMENT WITH 3.5 MM LCP PLATE, 11 MONTHS AFTER HAD PLATE BREAKAGE. SECOND TREATMENT WAS DONE USING A 4.5 PLATE AND BONE GRAFT. THERE WAS CONSOLIDATION. A CASE OF AN (B)(6) YEAR OLD FEMALE HAD AN ACCIDENTAL FALL WITH A 3.5 LCP PLATE FIXATION ,5 MONTHS AFTER HAD BONE FRAGMENT RESORPTION AND BREAKING HARDWARE. A CASE OF A (B)(6) YEAR OLD WITH AN INITILAS OF CM AT MAGGIORE HOSPITAL WHO HAD A SECOND TREATMENT USING A 4.5 PLATE BONE GRAFT HAD FRAGMENTS FAILURE. NO PLATE COMPRESSION. THIS REPORT IS FOR AN UNKNOWN LOCKING COMPRESSION PLATE (LCP). IT CAPTURES A CASE OF AN (B)(6) YEAR OLD WHO HAD PLATE AND SCREW LOOSENING AND HAD A SECOND TREATMENT WITH A 4.5 PLATE AND BONE GRAFT.THERE WAS NO CONSOLIDATION AND AFTER 5 MONTHS A CUTOUT OF THE PROXIMAL SCREWS FOR OSTEOPOROTIC BONE WAS DONE. THIS IS REPORT 5 OF 10 FOR (B)(4).

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
400358 PLATE,FIXATION,BONE HRS OBERDORF SYNTHES PRODUKTIONS GMBH

Patients

Seq Age Sex Outcome Treatment
1 80 YR Required Intervention