BD VACUTAINER® K2E 3.6MG PLUS BLOOD COLLECTION TUBES
Report
- Report Number
- 9617032-2019-00556
- Event Type
- Malfunction
- Date Received
- May 6, 2019
- Date of Event
- September 4, 2018
- Report Date
- May 16, 2019
- Manufacturer
- BECTON, DICKINSON AND COMPANY (BD)
- Product Code
- JKA
- PMA / PMN Number
- N/A
- Adverse Event
- Yes
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- MO
- Reporter Occupation
- OTHER HEALTH CARE PROFESSIONAL
Narratives
INVESTIGATION: INVESTIGATION SUMMARY: BD HAD NOT RECEIVED SAMPLES OR PHOTOS FROM THE CUSTOMER FACILITY FOR EVALUATION; THEREFORE, THE INVESTIGATION WAS LIMITED. A REVIEW OF THE DEVICE HISTORY RECORD WAS COMPLETED FOR THE INCIDENT LOT AND, BASED ON THIS REVIEW, ALL PRODUCT SPECIFICATIONS AND REQUIREMENTS FOR LOT RELEASE WERE MET; THERE WERE NO RELATED QUALITY NON-CONFORMANCES DURING MANUFACTURING OF THE PRODUCT. BD HAS INITIATED FURTHER INVESTIGATION RELATING TO THIS ISSUE THROUGH CAPA#161123. THE INVESTIGATION IS STILL ON-GOING AND IMPROVEMENTS WILL BE MADE AS THE POTENTIAL CAUSES OF THIS ISSUE ARE IDENTIFIED. INVESTIGATION CONCLUSION: AS NO SAMPLES OR PHOTOS WERE RECEIVED FOR EVALUATION, THE CUSTOMER'S INDICATED FAILURE MODE WAS NOT OBSERVED BY BD. HOWEVER, FURTHER INVESTIGATION HAS BEEN INITIATED THROUGH CAPA#161123. THE INVESTIGATION IS STILL ON-GOING AND IMPROVEMENTS WILL BE MADE AS THE POTENTIAL CAUSES ARE IDENTIFIED. ROOT CAUSE DESCRIPTION: ALTHOUGH NO SAMPLES OR PHOTOS WERE AVAILABLE FOR EVALUATION, BD HAS INITIATED FURTHER INVESTIGATION THROUGH CAPA#161123 TO IDENTIFY THE POTENTIAL ROOT CAUSE(S). RATIONALE: BASED ON AN ASSESSMENT OF SEVERITY AND FREQUENCY, IT WAS DETERMINED THAT A CAPA IS REQUIRED AT THIS TIME IN ORDER TO DETERMINE THE ROOT CAUSE ASSOCIATED WITH THIS ISSUE AND IMPLEMENT CORRECTIVE ACTIONS. THE INVESTIGATION IS CURRENTLY ON-GOING AND FURTHER IMPROVEMENTS WILL BE MADE AS THE POTENTIAL ROOT CAUSE(S) ARE IDENTIFIED.
IT WAS REPORTED THAT TUBES ARE UNDER FILLING WITH A BD VACUTAINER® K2E 3.6MG PLUS BLOOD COLLECTION TUBES. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: SOME UNDEFILED K2E 2ML TUBES. THE PHLEBOTOMY ACT WAS DONE CORRECTLY, BUT THE TUBE FILLING STOP AT <90% OF THE NOMINAL VOLUME.
"MULTIPLE LOT NUMBERS: THERE WERE MULTIPLE LOT NUMBERS REPORTED TO BE INVOLVED. THE INFORMATION FOR EACH LOT NUMBER IS AS FOLLOWS: MEDICAL DEVICE LOT #: 7297733; MEDICAL DEVICE EXPIRATION DATE: 2019-01-31; DEVICE MANUFACTURE DATE: 2017-10-24; MEDICAL DEVICE LOT #: 7268535; MEDICAL DEVICE EXPIRATION DATE: 2018-12-31; DEVICE MANUFACTURE DATE: 2017-09-25. " INITIAL REPORTER PHONE #: UNKNOWN. A DEVICE EVALUATION IS ANTICIPATED, BUT HAS NOT YET BEGUN. UPON COMPLETION OF THE INVESTIGATION, A SUPPLEMENTAL REPORT WILL BE FILED.
IT WAS REPORTED THAT TUBES ARE UNDER FILLING WITH A BD VACUTAINER® K2E 3.6MG PLUS BLOOD COLLECTION TUBES. THE FOLLOWING INFORMATION WAS PROVIDED BY THE INITIAL REPORTER: SOME UNDEFILED K2E 2ML TUBES. THE PHLEBOTOMY ACT WAS DONE CORRECTLY, BUT THE TUBE FILLING STOP AT <90% OF THE NOMINAL VOLUME.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 377989 | BD VACUTAINER® K2E 3.6MG PLUS BLOOD COLLECTION TUBES | BLOOD SPECIMEN COLLECTION DEVICE | JKA | BECTON, DICKINSON AND COMPANY (BD) | SEE H.10 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | Other |