FDA Adverse Event Malfunction Summary report: N

BARD® POLYURETHANE URETERAL CATHETERS, OPEN TIP

MDR report key: 8577487 · Received May 3, 2019

Report

Report Number
1018233-2019-02299
Event Type
Malfunction
Date Received
May 3, 2019
Report Date
June 3, 2019
Manufacturer
C.R. BARD, INC. (COVINGTON) -1018233
Product Code
EYB
PMA / PMN Number
EXEMPT
Product Problem
Yes
Report Source
Manufacturer report
Reporter Location
IA, US
Reporter Occupation
003

Narratives

Additional Manufacturer Narrative · 0

THE DEVICE WAS NOT RETURNED FOR EVALUATION. A POTENTIAL FAILURE MODE COULD BE ¿CATHETER DIAMETER INCORRECT¿. A POTENTIAL ROOT CAUSE FOR THIS FAILURE COULD BE ¿CATHETER OUTER DIAMETER TOO LARGE¿. THE LOT NUMBER IS UNKNOWN; THEREFORE, THE DEVICE HISTORY RECORD COULD NOT BE REVIEWED. THE INSTRUCTIONS FOR USE WERE FOUND ADEQUATE AND STATE THE FOLLOWING: "INDICATIONS FOR USE: THE BARD POLYURETHANE URETERAL CATHETERS ARE INTENDED FOR USE IN THE DRAINAGE OF URINE FROM THE URETER. THE POLYURETHANE URETERAL CATHETER IS INSERTED THROUGH THE URETHRA, INTO THE BLADDER AND UP THROUGH THE URETER. THESE CATHETERS ALSO ALLOW THE DELIVERY OF CONTRAST MEDIA. DIRECTIONS FOR USE: URETERAL CATHETERS ARE DESIGNED IN A VARIETY OF DISTAL TIP CONFIGURATIONS. THE ANATOMICAL CHARACTERISTICS OF THE URETERAL ORIFICE AND PHYSICIAN PREFERENCE SHOULD DETERMINE THE CHOICE OF DESIGN IN A SPECIFIC CLINICAL SITUATION. CLOSED TIP PLACEMENT (PLACED WITHOUT A GUIDEWIRE) AFTER PLACEMENT OF THE CYSTOSCOPE INTO THE BLADDER, THE URETERAL ORIFICE IS LOCATED AND EXAMINED AND A CHOICE OF URETERAL CATHETER IS MADE. THE CATHETER ADAPTER IS SECURED TO THE URETERAL CATHETER, AND THE CATHETER IS FLUSHED TO EVACUATE ALL AIR BUBBLES. UNDER DIRECT VISION, THE CATHETER TIP IS POSITIONED WITHIN THE URETERAL ORIFICE. CONTRAST MEDIA IS THEN INJECTED THROUGH THE URETERAL CATHETER INTO THE URETER. UNDER FLUOROSCOPY, THE URETER IS VISUALIZED AND REQUIRED INTERVENTION DETERMINED. OPEN TIP PLACEMENT (PLACED WITH A GUIDEWIRE) AFTER PLACEMENT OF THE CYSTOSCOPE INTO THE BLADDER, THE URETERAL ORIFICE IS LOCATED AND EXAMINED AND A CHOICE OF URETERAL CATHETER IS MADE. UNDER DIRECT VISION, THE GUIDEWIRE IS POSITIONED WITHIN THE URETERAL ORIFICE. THE URETERAL CATHETER IS INSERTED OVER THE GUIDEWIRE AND ADVANCED INTO THE URETER. THE GUIDEWIRE IS REMOVED AND THE CATHETER ADAPTER IS SECURED TO THE CATHETER. GENTLE ASPIRATION TO EVACUATE AIR FROM THE CATHETER CAN BE PERFORMED AT THIS TIME. CONTRAST MEDIA IS THEN INJECTED THROUGH THE URETERAL CATHETER INTO THE URETER. UNDER FLUOROSCOPY, THE URETER IS VISUALIZED AND REQUIRED INTERVENTION DETERMINED. WARNING: THIS UNIT SHOULD NOT BE USED AS A URETERAL SPLINT. CAUTION: DO NOT WITHDRAW URETERAL CATHETER WHILE IT IS DEFLECTED IN ENDOSCOPE. AVOID SHARP BENDING. CAUTION: DO NOT OVER-TIGHTEN THE CATHETER ADAPTER. OVER-TIGHTENING THE CATHETER ADAPTER MAY OCCLUDE THE LUMEN OF THE CATHETER. CAUTION: WHEN USING THE TIGERTAIL¿ CATHETER WITHOUT THE STABILIZING SUPPORT OF A GUIDEWIRE, BE AWARE THAT A MALFUNCTION MAY OCCUR WHERE THE FLEXIBLE TIP MAY DETACH IF EXCESSIVE FORCE IS MADE IN CONTACT WITH THE WALLS OF THE BLADDER, URETER OR RENAL PELVIS. SHOULD THE FLEXIBLE PORTION OF THE CATHETER BECOME DETACHED, RETRIEVE WITH AN ENDOUROLOGY GRASPING DEVICE." SECTION A THROUGH F - THE INFORMATION PROVIDED BY BD REPRESENTS ALL OF THE KNOWN INFORMATION AT THIS TIME. DESPITE GOOD FAITH EFFORTS TO OBTAIN ADDITIONAL INFORMATION, THE COMPLAINANT / REPORTER WAS UNABLE OR UNWILLING TO PROVIDE ANY FURTHER PATIENT, PRODUCT, OR PROCEDURAL DETAILS TO BD.

Description of Event or Problem · 0

IT WAS REPORTED THAT THE URETHRAL CATHETER SEEMED SLIGHTLY LARGER THAN USUAL, WHICH MADE IT DIFFICULT TO PASS THROUGH THE URETER. THE COMPLAINANT REPORTEDLY USED A 0.035 GUIDE WIRE WITH THE CATHETER.

Additional Manufacturer Narrative · 1

THE INVESTIGATION IS STILL IN PROGRESS. ONCE THE INVESTIGATION IS COMPLETE A SUPPLEMENTAL REPORT WILL BE FILED. THE INFORMATION PROVIDED BY BD REPRESENTS ALL OF THE KNOWN INFORMATION AT THIS TIME. DESPITE GOOD FAITH EFFORTS TO OBTAIN ADDITIONAL INFORMATION, THE COMPLAINANT / REPORTER WAS UNABLE OR UNWILLING TO PROVIDE ANY FURTHER PATIENT, PRODUCT, OR PROCEDURAL DETAILS TO BD. THE DEVICE WAS NOT RETURNED.

Description of Event or Problem · 1

IT WAS REPORTED THAT THE URETHRAL CATHETER SEEMED SLIGHTLY LARGER THAN USUAL, WHICH MADE IT DIFFICULT TO PASS THROUGH THE URETER. THE COMPLAINANT REPORTEDLY USED A 0.035 GUIDE WIRE WITH THE CATHETER.

Devices

Seq Brand Generic Product Code Manufacturer Model Lot UDI-DI
372486 BARD® POLYURETHANE URETERAL CATHETERS, OPEN TIP URETERAL CATHETER EYB C.R. BARD, INC. (COVINGTON) -1018233 UNK

Patients

Seq Age Sex Outcome Treatment
1