2.7 DEGREE STRAIGHT SAGITAL SAW
Report
- Report Number
- 3005985723-2019-00328
- Event Type
- Malfunction
- Date Received
- May 2, 2019
- Date of Event
- April 16, 2019
- Report Date
- July 8, 2019
- Manufacturer
- MAKO SURGICAL CORP.
- Product Code
- OLO
- UDI-DI
- 00848486032111
- PMA / PMN Number
- K143752
- Product Problem
- Yes
- Report Source
- Manufacturer report
- Reporter Location
- US
- Reporter Occupation
- OTHER
Narratives
REPORTED EVENT: STRAIGHT "SAW BLADE" ATTACHMENT STOPPED WORKING IN MID CUT. CASE TYPE: TKA. SURGICAL DELAY: 16-30 MINUTES. FUNCTIONAL INSPECTION: TURNING THE INPUT SHAFT BY BAND DOES NOT PRODUCE ANY MOTION AT THE BLADE PLATFORM. THE FAILURE MODE IS CONFIRMED. VISUAL INSPECTION: SHOWS THAT THE INPUT SHAFT BEARINGS HAVE BROKEN APART AND SLIPPED OFF THE SHAFT. SEE ATTACHED PICTURE. DIMENSIONAL INSPECTION: NOT PERFORMED AS THE VISUAL AND FUNCTIONAL INSPECTION ARE SUFFICIENT TO CONFIRM THE FAILURE. MATERIAL ANALYSIS: NOT PERFORMED AS NO MATERIAL FAILURE IS ALLEGED. PRODUCT HISTORY REVIEW: PRODUCT HISTORY REVIEW RESPECTIVELY SHOWS THE NUMBER OF DEVICES MANUFACTURED, DEVICES THAT FAILED INSPECTION, AND THEIR NC/NPR/QT NUMBERS IF APPLICABLE. DATE INSPECTED: 01-29-2019, DEVICES MANUFACTURED: (B)(4), DEVICES FAILED INSPECTION: 0, NC/NPR/QT NUMBERS: 0. PRODUCT HISTORY REVIEW SHOWS NO NON-CONFORMANCES WERE IDENTIFIED DURING INSPECTION. COMPLAINT HISTORY REVIEW: A REVIEW OF COMPLAINTS RELATED TO P/N: 212186, LOT NUMBER: 35030119 SHOWS NO ADDITIONAL COMPLAINT(S) RELATED TO THE FAILURE IN THIS INVESTIGATION. COMPLAINTS RELATED TO P/N: 212186 WILL BE TRACKED BY TREND REQUEST# (B)(4). CONCLUSION: THE COMPLAINT OF THE SAW ATTACHMENT NOT WORKING WAS CONFIRMED. THE FAILURE WAS TRACED TO THE BEARINGS ON THE INPUT SHAFT BREAKING APART. CORRECTIVE ACTION/PREVENTIVE ACTION: NO ACTION IS REQUIRED AT THIS TIME AS THERE IS NO INDICATION TO SUGGEST A PRODUCT NON-CONFORMITY OR UNANTICIPATED HAZARD.
STRAIGHT "SAW BLADE" ATTACHMENT STOPPED WORKING IN MID CUT. CASE TYPE: TKA. SURGICAL DELAY: 16-30 MINUTES.
¿AS PART OF NORMAL COMPLAINT FOLLOW-UP, AN EVALUATION OF THE EVENT HAS BEEN INITIATED BY MAKO SURGICAL. A SUPPLEMENTAL REPORT WILL BE SUBMITTED WHEN ADDITIONAL INFORMATION BECOMES AVAILABLE.¿
STRAIGHT SAWBLADE ATTACHMENT STOPPED WORKING IN MID CUT. CASE TYPE: TKA. SURGICAL DELAY: 16-30 MINUTES.
Devices
| Seq | Brand | Generic | Product Code | Manufacturer | Model | Lot | UDI-DI |
|---|---|---|---|---|---|---|---|
| 368207 | 2.7 DEGREE STRAIGHT SAGITAL SAW | STEREOTAXIC DEVICE, ROBOTICS | OLO | MAKO SURGICAL CORP. | 35030119 / 3505311 | 00848486032111 |
Patients
| Seq | Age | Sex | Outcome | Treatment |
|---|---|---|---|---|
| 1 | 61 YR | Hospitalization |